Setting the DMX address:

The DMX mode enables the use of a universal DMX controller. Each fixture requires a “start address” 
from 1- 511. A fixture requiring one or more channels for control begins to read the data on the channel 
indicated by the start address. For example, a fixture that occupies or uses 7 channels of DMX and was 
addressed to start on DMX channel 100, would read data from channels: 100,101,102,103,104,105 
and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in the 
chain starts at 107.

DMX 512:

DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent 
fixtures and controllers. A DMX controller sends DMX data instructions form the controller to the fixture. 
DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT”  
XLR terminals located on all DMX fixtures (most controllers only have a data “out” terminal).

DMX linking:

DMX is a language allowing all makes and models of different manufactures to be linked together  
and operate from a single controller, as long as all fixtures and the controller are DMX compliant.  
To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest  
cable path possible. The order in which fixtures are connected in a DMX line does not influence the  
DMX addressing. For example; a fixture assigned to a DMX address of 1 may be placed anywhere in  
a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a  
DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit,  
no matter where it is located in the DMX chain.

DATA cable (DMX cable) requirements (for DMX operation):

This fixture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit. 
Your unit and your DMX controller require a standard 3-pin XLR connector for data input/output,  
see image below.

Note: DMX cable must be daisy chained and cannot be split.

DMX setup

Further DMX cables can be 

purchased from all good sound 

and lighting suppliers or  

Pro Light Concepts dealers.
Please quote:

CABL10 – 2m
CABL11 – 5m
CABL12 – 10m

Содержание ELUM023

Страница 1: ...Order codes ELUM023 Evora 1000 Spot User Manual ...

Страница 2: ...quipment and the power cable periodically If the equipment is dropped or damaged disconnect the mains power supply immediately and have a qualified engineer inspect the equipment before operating again If the equipment has been exposed to drastic temperature fluctuation e g after transportation do not connect power or switch it on immediately The arising condensation might damage the equipment Lea...

Страница 3: ...efresh rate Motorised focus 3 facet circular rotating indexable prism plus 5 facet linear rotating indexable prism Frost filter Gobo wheel 1 7 rotating indexable replaceable gobos open Gobo wheel 2 9 static gobos open Colour wheel 7 colours open DMX channels 15 RDM Remote Device Management Auto sound active and master slave modes Pan tilt auto correction 16 Bit pan tilt positioning Pan 540 Tilt 27...

Страница 4: ... output 09 PowerCON input 10 PowerCON output 11 Fuse T4A 250V 12 Fans In the box 1 x fixture 2 x omega clamps 1 x power cable 1 x user manual POWER INPUT 100 240V 50 60Hz FUSE T4A 250V 3 PIN DMX INPUT 5 PIN DMX INPUT 3 PIN DMX OUTPUT 5 PIN DMX OUTPUT 100 240V 50 60Hz POWER OUTPUT POWER CONSUMPTION 290W DISPLAY BACKUP MIC MENU UP LEFT ENTER RIGHT DOWN Evora 1000 Spot 12 07 05 11 02 03 12 01 10 08 0...

Страница 5: ...metal head plate 3 Carefully remove one of the gobo trays by lifting slightly and pulling towards you releasing the tray from the spring clip 4 Now you can remove the circlip followed by the gobo from the gobo tray Replace the gobo and fit the circlip back into the tray 5 Place the gobo tray back into the gobo wheel by sliding it back under the spring clip and pushing it down into the wheel 6 Fast...

Страница 6: ...attery To access this press and hold the DISPLAY BACKUP button for 5 seconds until the fixtures home screen is displayed The LCD display will automatically shut off after 20 seconds of inactivity Error Codes When the unit is powered on the unit will automatically perform a motor reset If there is a problem with one or more of the motors the display will flash 5 times and display pan tilt error on ...

Страница 7: ... def Off PRO def Sound Setting Sound Sense 000 100 090 PRO AUTO def Sound Sensitivity Setting Pan Inverse No PRO AUTO def Yes Pan Inverse Setting Tilt Inverse No PRO AUTO def Yes Tilt Inverse Setting Back Light On AUTO def Off PRO def Back Light Setting Focus Adjust 000 255 016 Gobo Wheel 1 Focus Setting Focus2 Adjust 000 255 061 Gobo Wheel 2 Focus Setting FunctionDelay No Delay PRO AUTO def 1S De...

Страница 8: ...ion CH8 when split colour is enabled in the menu see page 6 000 007 Open white 008 016 Split colour Open Red 017 025 Red 026 033 Split colour Red Orange 034 042 Orange 043 050 Split colour Orange Green 051 059 Green 060 067 Split colour Green Blue 068 076 Blue 077 084 Split colour Blue Hot Pink 085 093 Hot Pink 094 101 Split colour Hot Pink Purple 102 110 Purple 111 118 Split colour Purple Yellow ...

Страница 9: ...w fast 113 119 Gobo 8 shake slow fast 120 127 Gobo 9 shake slow fast 128 189 Gobo wheel scroll CW fast slow 190 193 Gobo scroll stop 194 255 Gobo wheel scroll CCW slow fast CH12 000 006 Open 007 088 3 facet prism 089 172 5 facet prism 173 255 Frost filter CH13 000 127 Prism indexing 128 189 Prism rotation CCW fast slow 190 193 Prism rotation stop 194 255 Prism rotation CW slow fast CH14 000 255 Fo...

Страница 10: ... 1000 Spot User Manual 10 Operating instructions Rotating gobos Gobo size 20 5mmØ Image size 16 5mmØ Gobo 1 Gobo 2 Gobo 3 Gobo 4 Gobo 5 Gobo 6 Gobo 7 Static gobos Gobo 1 Gobo 2 Gobo 3 Gobo 4 Gobo 5 Gobo 6 Gobo 7 Gobo 8 Gobo 9 ...

Страница 11: ... DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX address...

Страница 12: ... 5 pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The diagram below details the correct cable conversion Termination reduces signal transmission problems and interference It is always ad...

Страница 13: ...ssible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally...

Страница 14: ...www prolight co uk Evora 1000 Spot User Manual 14 ...

Страница 15: ...www prolight co uk Evora 1000 Spot User Manual 15 ...

Страница 16: ...www prolight co uk Evora 1000 Spot User Manual 16 ...

Отзывы: