Technical data
34 Operating instructions RHD
ELTROPLAN
-
REVCON
Elektrotechnische Anlagen GmbH
5.2
Fuses and wire cross sections
The power feed/feedback unit is connected to mains supply via the terminals L
1
-L
3
at the
terminal plate. Mains fuses must be designed according to the current load capacity of the
supply wire.
5.2.1 Series fuses RHD B0/D0
Semiconductor fuses have to be connected in series with the power feedback unit as fol-
lowing tables (refer to figure 4.4.1.1.1 position 1). The listed manufacturer is recom-
mended, but naturally also comparative fuses of other manufacturer (e.g. Jean Müller, Fer-
raz, and Bussmann) are suitable.
REVCON
®
- type
RLD B0/D0
Max. fuse AC
Connection terminal and
max. cross section of the
supply line*
4-230-50-0-A
Siba 5012406.20 20A 690V 10x38mm
ES
25mm²
7-230-50-0-A
Siba 5017906.30 30A 690V 14x51mm
ES
25mm²
10-230-50-0-A
Siba 5012406.50 50A 690V 14x51mm
ES
25mm²
13-230-50-0-A
Siba 5014006.80 80A 690V 22x58mm
ES
25mm²
17-230-50-0-A
Siba 5014006.80 80A 690V 22x58mm
ES
25mm²
25-230-50-0-A
Siba 5014006.100 100A 690V 22x58mm
ES
25mm²
40-230-50-0-A
Siba 2018920.200 200A 690V NH 00
ES
50mm²
55-230-50-0-A
Siba 2018920.315 315A 690V NH 00
ES
150mm²
70-230-50-230-A Siba 2018920.350 350A 690V NH 00
ES 150mm²
85-230-50-230-A Siba 2071332.400 400A 1100V NH 1
ES
150mm²
115-230-50-230-A Siba 2071332.500 500A 1100V NH 1
ES 240mm²
145-230-50-230-A Siba 2071332.630 630A 1100V NH 1
ES
240mm²
Table 5.2.1.1
REVCON
®
- type
RLD B0/D0
Max. fuse AC
Connection terminal and
max. cross section of the
supply line*
7-400-50-0-A
Siba 5012406.20 20A 690V 10x38mm
ES
25mm²
13-400-50-0-A
Siba 5017906.30 30A 690V 14x51mm
ES
25mm²
18-400-50-0-A
Siba 5012406.50 50A 690V 14x51mm
ES
25mm²
24-400-50-0-A
Siba 5014006.80 80A 690V 22x58mm
ES
25mm²
30-400-50-230-A Siba 5014006.80 80A 690V 22x58mm
ES
25mm²
50-400-50-230-A Siba 2018920.160 160A 690V NH 00
ES
25mm²
70-400-50-230-A Siba 2018920.160 160A 690V NH 00
ES
50mm²
100-400-50-230-A Siba 2018920.250 250A 690V NH 00
ES
150mm²
125-400-50-230-A Siba 2018920.315 315A 690V NH 00
ES
150mm²
150-400-50-230-A Siba 2071332.400 400A 1100V NH 1
ES
150mm²
200-400-50-230-A Siba 2071332.500 500A 1100V NH 1
ES
240mm²
250-400-50-230-A Siba 2071332.630 630A 1100V NH 1
ES
240mm²
Table 5.2.1.2
Содержание REVCON RHD B0 400V
Страница 46: ...Installation Operating instructions RHD 45 ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 1 Enclosure 1 500 ...
Страница 47: ...Installation 46 Operating instructions RHD ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 2 Enclosure 2 700 ...
Страница 48: ...Installation Operating instructions RHD 47 ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 3 Enclosure 3 800 ...
Страница 49: ...Installation 48 Operating instructions RHD ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 4 Enclosure 3 801 ...
Страница 52: ...Installation Operating instructions RHD 51 ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 4 Diagram Case 4 ...