WOP-2ac-LR2. User manual
45
5 Spectrum Analyzer
To use the embedded spectrum analyzer on the WOP-2ac-LR2, you need to login to the device via telnet or ssh.
Enter the
monitoring spectrum-analyzer
command to run it.
The analysis time for all the radio channels in the range is approximately 5 minutes.
As a result of the spectrum analyzer operation, information on the loading of each channel (in percent) will be
displayed in the console:
WOP-2ac-LR2(root):/# monitoring spectrum-analyzer
Channel| CCA
1
|
57
%
2
|
39
%
3
|
12
%
4
|
6
%
5
|
47
%
6
|
43
%
7
|
30
%
8
|
5
%
9
|
9
%
10
|
42
%
11
|
56
%
12
|
24
%
13
|
18
%
Please note that all clients will disconnect from the base station during spectrum analyzer operation.