BA-en-2083-1909_RX22
19
8. Technical specifications RX22 STATICJET
Supply voltage
Power input
Output voltage
Ambient operating
temperature
Storage temperature
Ambient humidity
Optical indicator
Fault signal contact
Air supply
Air temperature
Mains power
Ground link
Enclosure
Emission tip
Protection class
Dimensions
Weight
24 V DC +/- 10 %
2.4 VA max.
6 kV AC +/- 250 V / 33 kHz
0 °C...+40°C (+32°F...+104°F)
0 °C...+50°C (+32°F...+122°F)
max. 80% r.h., non-dewing
LED on enclosure:
green: high voltage active
red:
malfunction
NPN - open collector,
U = max. 40 V DC, I = max. 20 mA
D
a
8 mm (outside tolerated hose)
max. 0.2 MPa, dry, oil-free, filtered compressed
air or nitrogen
0...+40°C (+32...+104°F) non-dewing,
always avoid rapid changes in temperature
socket contact with plug,
power supply as accessory available
internal M4 thread on both sides of the
enclosure, max. screw-in depth 5 mm
stainless steel, polyamide
titanium alloy
IP20, according to EN 60529
54 x 73 x 31 mm (H x W x D)
without nozzle and air hose (see Fig. 6)
approx. 175 g without power supply