5. Maintenance
Warning!
Electric shock hazard!
Switch the power supply off and disconnect the supply voltage before
carrying out any maintenance or repair work.
The machine in which the discharging bars are installed must not be in
operation. Maintenance work must be carried out by trained or qualified
personnel.
5.1 Power supply
The power supply must be checked regularly to ensure its proper func-
tioning. The connections of the high voltage cables must be free of dirt
and other foreign matter. The intervals for the check depend on the appli-
cation and must hence be defined by the user according to the operating
conditions. The power supply itself does not require any maintenance.
Check for correct ground connection!
5.2 Discharging bars
To ensure the trouble-free function of the discharging bars, clean the bars
at least once a week with compressed air free of oil and water (max. 6 bar
and standard compressed air pistol) and a brush with soft plastic bristles.
Refer to the operating instructions for the bar used.
Dirt deposits settling on the bars (e.g. grease) must be cleaned off using a
suitable solvent (benzine). Do not soak the bars and the high voltage
cable in solvent!
Caution!
Risk of deflagration!
Allow the solvent to evaporate completely before restarting the unit.
Do not damage the emission tips of the bars.