7
Elterm M.M.Kaszuba Sp.J., ul. Przemysłowa 5, 86-200 Chełmno
zero meaning no compensation. In standard operation mode, boiler maintains preset temperature
increased by adjustment parameter in accordance with below table.
For every outside temperature degree below 15°C, adjustment parameters are as follow
:
K=1
0,1°C
K=3
0,3°C
K=5
0,5°C
K=7
0,7°C
K=9
0,9°C
K=2
0,2°C
K=4
0,4°C
K=6
0,6°C
K=8
0,8°C
K=10
1,0°C
Example (
H
): Curve is set on K=5 with boiler preset temperature 30°C. For outside temperature over 15°C,
boiler maintains 30°C. When it cools down to 5°C, adjustment will estimate: 10 x 0,5 = 5°C (degrees below
15°C x value for K=5), so the boiler will maintain 35°C; when it’s -5°C, adjustment will estimate 20 x 0,5 =
10°C, so the boiler will maintain 40°C, etc.
Room temperature setting on boiler
(
I
) - enter function from home screen (
C
) by pressing ↓, using ↑↓
change preset room temperature in range 5-30°C.
Detailed settings
(multiple pressing of
causes return to main menu)
Menu structure
(
J
,
K
,
L
):
1. Settings
1.1.
Power
1.2.
Sections
1.3.
Date & time
1.4.
PID-P
1.5.
Hysteresis CO
1.6.
Hysteresis CWU
1.7.
Default settings
1.8.
Room programs
1.9.
DHW programs
1.10.
Circulation pump
1.11.
Circulation time
2. Energy consumption
3. Venting
1.1.
Settings/Power
– press
on home screen (
C
) and enter SETTINGS (
J
), then choose Power (
K
) and
press
once more. Using ↑↓ change boiler power in range 33/66/100% (
M
). The choice is set by pressing
.
1.2.
Settings/Sections
– press
on home screen (
C
) and enter SETTINGS (
J
), then choose Sections (
K
) and
press
once more. Using ↑↓ switch between C.H. and D.H.W. (
N
). Press
to enter chosen section and
using ↑↓ switch between active (ON)(
O
) and inactive (OFF)(
P
) status. The choice is set by pressing
.