Settings/Circulation  time

  –  press

  on  home  screen  (

C

)  and  enter  SETTINGS  (

J

),  then  choose 

Circulation time and press

 once more. Using ↑↓ change parameter value, which is then set by pressing

 

 

 

2. Energy consumption

 - press

 on home screen (

C

) and enter ENERGY CONSUMPTION (

J

). Press

 once 

more to display energy consumption counters (

c

). Using → reset erasable counter (

RES. COUNTER

) – which 

shows consumed energy in kWh since measurement start till any given moment within 24h time span. After 
24  hours,  counter  stops  automatically. 

LAST  24H

  –  calculates  energy  consumption  over  the  last  24  hours 

with 20 min. updates. 

 - return. 

 

3.  Venting

  –  function  enables  additional  system  venting  without  turning  boiler  off.  Proper  system  venting 

guarantees  its  correct  and  prolonged,  faultless  operation.  Function  also  enables  to  check  proper 
pump/pumps  work.  Press

  on  home  screen  (

C

)  and  enter  VENTING  (

J

).  Press

  once  more  to  display 

D.H.W./C.H. options (

d

). Using ↑↓ change parameter value- ON/OFF (

e

), which is then set by pressing

 

Do not remove boiler external metal 

casing once device remains turned on

In case boiler is activated by mistake with no water inside, wait until heaters cool down, fill device with 
water and switch it on again. Under no circumstances fill device with cold water with heaters still hot! 

Once water in central heating system is heated, system should be bled once again (special attention 
must be paid to the bleeding of the central heating pump and boiler air vent). 

 

For more information please visit

 

www.elterm.pl

 

 

 

 

 

 

Elterm  boilers  are  equipped  in 

AntiStop  function

.  Automatics  turns  the  pump  on  for  one  minute  once 

every 14 days, what prevents it's rotor from seizing. AntiStop operates independently from on/off mode. It 
is therefore highly recommended to keep boiler in off mode (red diode visible) in off-heating season - in 
this mode device uses just 0,5W! 

Содержание goldline asbii

Страница 1: ...less water heater for central heating systems Electric heating boiler GoldLine series RedLine series AsZN W Pułkownik Uranus Urano AsD W Generał Neptune Nettune AsDC W Marszałek Pluto Plutone AsBII Bateria Sun Sole AsHN Hetman Moon Luna AsBIV Dywizja Galaxy Galassia Please see video prior installation ...

Страница 2: ...ELECTRIC HEATING BOILERS for more detailed pictures please see www elterm pl Dimensions and components of AsD W boiler Dimensions and components of AsZN W boiler Dimensions and components of AsBII boiler Dimensions and components of AsDC W boiler Dimensions and components of AsDC W boiler ...

Страница 3: ...d for autonomous operation in both open and closed central heating systems safety unit expansion vessel and circulation pumps are included Boiler is build in on top of 100l hot utility water tank equipped with 29kW coil AsBII and AsBIV boilers in closed central heating system in closed type layout the central system needs to be equipped with an expansion vessel which is not supplied with above mod...

Страница 4: ...therefore must be done by a qualified electrician only Boilers are designed for alternating current 3 phase power supply 400V 3N 50Hz Models with 4 6 9 12 and 15kW powers are also available without any processing in 1 phase version 230V 1N 50Hz greater powers can also be prepared in 1 phase version upon request Boiler s power supply is connected to terminal strip labeled as L1L2L3N or to switch ig...

Страница 5: ...2 5 x 6 0 220 310 21 kW 100 67 33 by 1 6 3 phases 3 x 40 5 x 6 0 260 360 24 kW 100 67 33 by 1 6 3 phases 3 x 40 5 x 10 0 300 400 27 kW 100 67 33 by 1 6 3 phases 3 x 50 5 x 16 0 220 380 30 kW 100 67 33 by 1 6 3 phases 3 x 50 5 x 16 0 240 400 33 kW 100 67 33 by 1 6 3 phases 3 x 50 5 x 16 0 260 450 36 kW 100 67 33 by 1 6 3 phases 3 x 63 5 x 16 0 280 480 39 kW 100 67 33 by 1 6 3 phases 3 x 80 5 x 25 0...

Страница 6: ...ally for AsD W and there is no possibility do turn heaters on Pre set venting time should be sufficient to carry out the process if however it is not enough whole procedure needs to be repeated by turning boiler off and on again The display switches to the home screen C C H and D H W for AsD W i AsDC W temperature setting enter function from home screen C by pressing using choose either C H or D H...

Страница 7: ... will maintain 40 C etc Room temperature setting on boiler I enter function from home screen C by pressing using change preset room temperature in range 5 30 C Detailed settings multiple pressing of causes return to main menu Menu structure J K L 1 Settings 1 1 Power 1 2 Sections 1 3 Date time 1 4 PID P 1 5 Hysteresis CO 1 6 Hysteresis CWU 1 7 Default settings 1 8 Room programs 1 9 DHW programs 1 ...

Страница 8: ...e 1 or 2 1 5 Settings CH Hysteresis press on home screen C and enter SETTINGS J then choose CH Hysteresis K and press once more Using T change parameter value range 1 2 3 4 5 6 which is then set by pressing 1 6 Settings DHW Hysteresis press on home screen C and enter SETTINGS J then choose DHW Hysteresis L and press once more Using U change parameter value range 1 2 3 4 5 6 which is then set by pr...

Страница 9: ...m start 3 Program stop 4 Temp setting 20 70 C 5 Active yes no 6 Program number from 1 to 9 7 Function buttons 1 8 Settings ROOM programs press on home screen C and enter SETTINGS J then choose Room programs L and press once more Using Z switch between parameters weekdays working time temperature status using change parameter value which is then set by pressing 1 9 Settings DHW programs for AsD W a...

Страница 10: ... to check proper pump pumps work Press on home screen C and enter VENTING J Press once more to display D H W C H options d Using change parameter value ON OFF e which is then set by pressing Do not remove boiler external metal casing once device remains turned on In case boiler is activated by mistake with no water inside wait until heaters cool down fill device with water and switch it on again U...

Страница 11: ...requirements concerning Ecodesign for energy related products Attachment 13 EU Commission regulation nr 622 2012 With regard to Ecodesign requirements for glandless standalone circulators and glandless circulators integrated in products and that the standards hereinafter referred to have been duly applied and observed The harmonized standards applicable to the product to which this declaration of ...

Страница 12: ...e or assembly that is not in compliance with the user manual etc or in the event the guarantee is invalid the costs of repair and travelling are borne by the claimant 6 Failure on the part of the user to follow the serviceperson s recommendations provided in the guarantee repair protocol results in the guarantee being suspended until such recommendations are implemented Do not call servicemen with...

Отзывы: