10
Elterm M.M.Kaszuba Sp.J., ul. Przemysłowa 5, 86-200 Chełmno
1.11.
Settings/Circulation time
– press
on home screen (
C
) and enter SETTINGS (
J
), then choose
Circulation time and press
once more. Using ↑↓ change parameter value, which is then set by pressing
.
2. Energy consumption
- press
on home screen (
C
) and enter ENERGY CONSUMPTION (
J
). Press
once
more to display energy consumption counters (
c
). Using → reset erasable counter (
RES. COUNTER
) – which
shows consumed energy in kWh since measurement start till any given moment within 24h time span. After
24 hours, counter stops automatically.
LAST 24H
– calculates energy consumption over the last 24 hours
with 20 min. updates.
- return.
3. Venting
– function enables additional system venting without turning boiler off. Proper system venting
guarantees its correct and prolonged, faultless operation. Function also enables to check proper
pump/pumps work. Press
on home screen (
C
) and enter VENTING (
J
). Press
once more to display
D.H.W./C.H. options (
d
). Using ↑↓ change parameter value- ON/OFF (
e
), which is then set by pressing
.
Do not remove boiler external metal
casing once device remains turned on
.
In case boiler is activated by mistake with no water inside, wait until heaters cool down, fill device with
water and switch it on again. Under no circumstances fill device with cold water with heaters still hot!
Once water in central heating system is heated, system should be bled once again (special attention
must be paid to the bleeding of the central heating pump and boiler air vent).
For more information please visit
www.elterm.pl
Elterm boilers are equipped in
AntiStop function
. Automatics turns the pump on for one minute once
every 14 days, what prevents it's rotor from seizing. AntiStop operates independently from on/off mode. It
is therefore highly recommended to keep boiler in off mode (red diode visible) in off-heating season - in
this mode device uses just 0,5W!