Operating modes/charging mode (permanent settings)
2280073 Rev.1
Page 25
6.8 EPS mode
This operating mode enables power to be supplied to vehicles that have no battery. Once the
MC1500 has been switched on by pressing control button 1 (On/Off), it is ready for use. That
means that the MC1500’s output voltage will stay at zero volts until button 2 (Start/Stop) is
pressed.
The MC1500 then starts to charge at the relevant voltage.
The following table contains an overview of the default setting of voltage levels for the EPS
mode:
EPS 12V mode
EPS 24V mode
14.2V
28.0V
The output voltage on the MC1500 remains switched on until button 2 (Start/Stop) is pressed
again. When this button is pressed, the MC1500 switches the output voltage to 0V until control
button 2 (Start/Stop) is pressed once again. Then, the output voltage is switched back on again.
The output voltage can also be switched off by pressing button 1 (On/Off).
Connecting a battery (with a voltage of >1V) to the MC1500 before the output voltage is
switched on is not allowed. If this is done, a
‘Return voltage’
error message will appear.
The output voltage at the MC1500 cannot be switched on until the battery is removed.
Warning:
It is not permissible to connect a battery to the MC1500 while the charger unit is in EPS mode.
6.9 EPS autostart mode
This mode works in a similar way to the EPS mode. The difference between the two operating
modes is that the EPS autostart mode requires a battery to be connected to the MC1500.
The MC1500 automatically sets the output voltage according the battery connected.