background image

C

o

n

n

ec

to

A

ss

ig

n

m

en

ts

 

User's Manual 

 BAB 

740 

 

3—6

Connector Assignments 

3.2 

ADAP-200 Connectors 

3.2.1 8-bit SCSI  

Single-ended 8-bit SCSI signals are fed into row A and C of the 
VMEbus P2 connector (X2002). An ADAP-200 is plugged onto the 
rear side of the backplane to interface to standard 8-bit SCSI 
connectors (a 50-pin flat cable connector)  

If the BAB 740 is located at either end of the SCSI bus. J1601 must 
be installed for signal termination, otherwise J1601 must be 
removed. 

Table 9: SCSI Connector 8-bit X103 (on ADAP-200) 

 

Pin Description  Pin  Description 

 2

DB0 

28 

GND 

 4

DB1 

30 

GND 

 6

DB2 

32 

ATN 

 8

DB3 

34 

GND 

10

DB4 

36 

BSY 

12

DB5 

38 

ACK 

14

DB6 

40 

RST 

16

DB7 

42 

MSG 

18

DB8 

44 

SEL 

20

GND 

46 

CIO 

22

GND 

48 

REQ 

24

GND 

50 

I/O 

26

TERM-PWR 

 

 

 

 

All odd pins of the 50-pin SCSI connector except pin 25 are 
connected to ground. Pin 25 is left open. 

1

2

49

50

Front View 

Pin 26 is connected to +5 V via a Shottky diode to supply power to 
an external SCSI terminator. 

Содержание BAB 740

Страница 1: ...BAB 740 Basic Automation Board with PowerPC 740 manual Revision 2C...

Страница 2: ...Edition Valid for Hardware revision 1A 03 01 2000 AR 2A Valid for Hardware revision 3A 24 04 2001 G M 2B Valid for Hardware revision 3A Valid for Software revision W O9B7 106C I O Address Map changed...

Страница 3: ...are performed and what system is used electronic mechanic photocopying recording etc All product and company names are registered trademarks of the respective companies Our General Business Delivery O...

Страница 4: ...Consult the dealer or an experienced radio TV technician for help The us of shielded cables for connection of the monitor to the graphics card is required to assure compliance with FCC regulations Cha...

Страница 5: ...and adding devices on it carefully read the manuals that came with the package Before using the product make sure all cables are correctly connected and the power cables are not damaged If you detect...

Страница 6: ...ycle packaging environmentally friendly Packaging materials are recyclable Please do not dispose packaging into domestic waste but recycle it Please recycle old or redundant devices environmentally fr...

Страница 7: ...l 1 2 1 2 2 Flash Memory 1 2 1 2 3 PCI Devices 1 2 1 2 4 VMEbus Interface 1 3 1 2 5 Mechanical 1 3 1 2 6 I O 1 3 1 2 7 Software 1 4 1 2 8 Compatibility 1 4 1 2 9 Related Documents 1 4 2 Installation 2...

Страница 8: ...ors 3 2 3 1 4 Parallel I O Connector 3 3 3 1 5 VMEbus Connector P1 3 4 3 2 ADAP 200 Connectors 3 6 3 2 1 8 bit SCSI 3 6 3 2 2 Additional I O 3 7 3 3 CONV 300 Connectors 3 8 3 4 ADAP 740 Connectors 3 9...

Страница 9: ...meters 4 1 4 1 Host Bus 4 1 4 2 VMEbus 4 1 4 3 PCI Local Bus 4 4 4 4 Network 4 4 4 5 SCSI 4 5 4 6 Serial I O 4 5 4 7 Keyboard 4 5 4 8 Mouse 4 6 4 9 Parallel I O 4 6 4 10 MTBF Values 4 6 4 11 ESD Value...

Страница 10: ...6 2 6 2 1 Entering Boot Parameters 6 2 6 2 2 Printout of Boot Screen 6 2 6 2 3 Ethernet Boot Printout 6 3 7 Appendix 7 1 7 1 Description of On board Devices 7 1 7 1 1 SMI Ticker 7 1 7 1 2 Enhanced Se...

Страница 11: ...User s Manual Table of Contents BAB 740 V 7 1 9 PCI IDSEL 7 9 7 2 Factory settable Jumpers 7 9...

Страница 12: ...P1 X2001 3 4 Table 8 Pin Assignment of Connector P2 X2002 3 5 Table 9 SCSI Connector 8 bit X103 on ADAP 200 3 6 Table 10 50 Pin I O Connector X102 on ADAP 200 3 7 Table 11 COM3 COM4 9 pin min D connec...

Страница 13: ...Table 24 VMEBus SYSRESET J1706 J1902 5 3 Table 25 VMEBus SYSFAIL J1901 5 4 Table 26 COM3 Configuration J2201 J2202 X2201 5 4 Table 27 COM4 Configuration J2203 J2204 X2202 5 4 Table 28 PMC Slot 1 PCIR...

Страница 14: ...le 39 CPU Drive Strength Configuration J101 J102 7 9 Table 40 CPU PLL Configuration J103 J106 7 10 Table 41 System Clock J111 J112 J113 7 10 Table 42 MPC106 PLL Configuration J110 J107 7 11 Table 43 C...

Страница 15: ...tents BAB 740 IX List of Figures Figure 1 Block Diagram 1 5 Figure 2 Connection Diagram 2 1 Figure 3 Parts Side Jumpers 5 1 Figure 4 Solder Side Jumpers 5 2 Figure 5 PMCE 740 Jumpers 5 5 Figure 6 BAB...

Страница 16: ...Table of Contents User s Manual BAB 740 X...

Страница 17: ...ansfers decoupled from board internal PCI transfers Flash Eprom 2 MB onboard Flash programmable byte access implemented in hardware Network interface Ethernet using DEC21143 10 100 Mbps with PCI DMA 1...

Страница 18: ...44 pin SO DIMM modules 64 bit data bus Memory size can be anywhere between 8 and 128 MB depending on the DIMM modules used Two sockets can be equipped with SO DIMM modules but the board is also runnin...

Страница 19: ...bit data transfers in master and slave mode Additionally bus controller arbiter functionality is available Use of the BAB 740 without VMEbus is possible only power must be supplied through VME connec...

Страница 20: ...rnet or through the PCI bus BIOS functionality is supplied in the form of the boot program used to start the operating system OS 9 VxWorks It also contains power on self test routines and PCI device a...

Страница 21: ...bus SCSI Interface Ethernet Interface IDE Interface Serial 3 4 Serial 1 2 Parallel PS2 Mouse Keyboard Super I O Controller PC97307 PCI PMC Slot 2 Memory SO DIMM Sockets Enhanced Serial Comm Controller...

Страница 22: ...Specification Specification User s Manual BAB 740 1 6...

Страница 23: ...on User s Manual BAB 740 2 1 2 Installation 2 1 BAB 740 I O Figure 2 Connection Diagram PMC I O PMC Slot PMC Slot Status Control Keyboard Mouse Ethernet SCSI Serial 1 Serial 2 Serial 3 syncron Paralle...

Страница 24: ...CE have an internal connection be sure to install resp remove the two board package carefully and simultaneously 2 1 2 What s needed for Installation The BAB 740 must be installed into a 32 bit VMEbus...

Страница 25: ...estrictions and recommendations SDRAMs should be 100 MHz or faster FPMODE or EDO RAMs should be 60 ns or faster X701 must be populated with a memory module If two memory modules are installed they sho...

Страница 26: ...t panel of the BAB 740 The LEDs have a pulse stretcher to make short pulses visible Table 1 Activity LEDs LED Color Description RUN Green CPU data bus in usage DISK Yellow access to IDE or SCSI bus LN...

Страница 27: ...ts before making any connections 3 1 On board Connectors 3 1 1 Keyboard and Mouse Connector Table 2 KEYB 6 pin miniature circular connector Pin Signal 1 KBDATA 2 nc 3 GND 4 5V 5 KBCLK 6 nc 6 2 1 4 3 5...

Страница 28: ...onnector Table 4 ETHERNET 8 pin telephone jack connector Front View 1 8 Pin Signal 1 TXD 2 TXD 3 RXD 4 nc 5 nc 6 RXD 7 nc 8 nc 3 1 3 Serial Ports 1 and 2 Connectors Table 5 COM1 COM2 9 pin min D conne...

Страница 29: ...Manual BAB 740 3 3 3 1 4 Parallel I O Connector Table 6 PRN 25 pin min D connector Front View Pin Signal 1 STROBE 2 D1 3 D2 4 D3 5 D4 6 D5 7 D6 8 D7 9 D8 10 ACK 11 BUSY 12 PE Paper End 13 SLCT 14 AUT...

Страница 30: ...D07 BG2IN D15 9 GND BG2OUT GND 10 SYSCLK BG3IN SYSFAIL 11 GND BG3OUT BERR 12 DS1 BR0 SYSRESET 13 DS0 BR1 LWORD 14 WRITE BR2 AM5 15 GND BR3 A23 16 DTACK AM0 A22 17 GND AM1 A21 18 AS AM2 A20 19 GND AM3...

Страница 31: ...G 12 IDEIOCS16 GND MTR0 13 INDEX 5 V DR0 14 DR1 D16 DIR 15 STEP D17 SCSIATN 16 WGATE D18 IDEDB 14 17 IDEDB 15 D19 SCSIBSY 18 SCSIACK D20 SCSIRST 19 SCSIMSG D21 SCSISEL 20 SCSIC D D22 SCSIREQ 21 SCSII...

Страница 32: ...er end of the SCSI bus J1601 must be installed for signal termination otherwise J1601 must be removed Table 9 SCSI Connector 8 bit X103 on ADAP 200 Pin Description Pin Description 2 DB0 28 GND 4 DB1 3...

Страница 33: ...Channel 4 TXD may be changed if a 29 O Serial Channel 4 RTS non standard level 30 I Serial Channel 4 RXD converter board SILC is 31 not connected installed 32 not connected 33 Serial Channel 3 GND2 3...

Страница 34: ...View Pin 1 Table 11 COM3 COM4 9 pin min D connector Pin RS232 async Signal default RS232 sync Signal RS422 async Signal RS422 sync Signal 1 DCD DCD CTS RCLK 2 RXD RXD RXD RXD 3 TXD TXD TXD TXD 4 DTR D...

Страница 35: ...for the floppy drive must be connected directly to the power supply Table 12 Pinout Floppy Connector X101 on ADAP 740 Pin Name Name Pin 1 Gnd DRVDEN0 2 3 Gnd nc 4 5 Gnd DRVDEN1 6 7 Gnd INDEX 8 9 Gnd M...

Страница 36: ...CD ROM can be connected Cable length should not exceed 40 cm to avoid instable operation EIDE is only available on board versions with EIDE option Table 13 Pinout EIDE Connector X105 on ADAP 740 Pin N...

Страница 37: ...2 nc nc nc nc 3 RXD RXD RXD RXD 4 RTS TCLK RTS TCLK 5 TXD TXD TXD TXD 6 CTS RCLK CTS RCLK 7 DTR DTR RTS TCLK 8 nc 5V nc 5V RXD RXD 9 GND GND TXD TXD 10 nc nc nc nc Front View 9 10 1 2 The pinout of X1...

Страница 38: ...ed by two PMC Modules 3 5 1 PMCE 740 VMEbus Connector P1 Only GND 5V and 12V are routed from the VMEbus Connector P1 to the Power Connector X403 No VMEbus Signals are used Table 16 PMCE 740 VMEbus Con...

Страница 39: ...9 V I O AD 31 20 19 AD 30 AD 29 20 21 AD 28 AD 27 22 21 GND AD 26 22 23 AD 25 GND 24 23 AD 24 3 3V 24 25 GND C BE 3 26 25 IDSEL AD 23 26 27 AD 22 AD 21 28 27 3 3V AD 20 28 29 AD 19 5V 30 29 AD 18 GND...

Страница 40: ...P2 33 1 1C 33 17C 34 2 1A 34 17A 35 3 2C 35 18C 36 4 2A 36 18A 37 5 3C 37 19C 38 6 3A 38 19A 39 7 4C 39 20C 40 8 4A 40 20A 41 9 5C 41 21C 42 10 5A 42 21A 43 11 6C 43 22C 44 12 6A 44 22A 45 13 7C 45 23...

Страница 41: ...Connector Assignments Connector Assignments User s Manual BAB 740 3 15 3 5 4 PMCE 740 Power Connector Table 19 PMCE 740 Power Connector X403 Pin Description 1 5V out 2 GND 3 GND 4 12V out...

Страница 42: ...Connector Assignments User s Manual BAB 740 3 16 Connector Assignments...

Страница 43: ...specification ANSI IEEE STD 1014 1987 Rev D1 4 VMEbus Master Slave Capabilities Single cycle A16 A24 A32 A64 D08 EO D16 D32 UAT A40 D08 EO D16 MD32 RMW Master only A16 A24 A32 D08 EO D16 D32 A40 D08 E...

Страница 44: ...16 32 64 forever IACK daisy chain driver SYSCLK driver Arbiter Options PRI RRS SGL BBSY filter Requester Options Any one of BR 0 3 RWD ROR ROC Bus ownership timer 16 ms 1024 ms forever Interrupt Handl...

Страница 45: ...CI target VME master windows base and size programmable 64 KB to 4 GB window size any of specified address capabilities or user defined Four VME slave PCI initiator windows base and size programmable...

Страница 46: ...us CPU to PCI Transfer Options Write post buffer Max 120 MB s peak PCI to Memory Transfer Options Max 120 MB s peak Clock Speed 33 3 MHz IRQs Four PCI interrupts rerouted to selectable ISA interrupts...

Страница 47: ...ynchronous transfer 7 MB s synchronous transfer 20 MB s ultra SCSI 4 6 Serial I O 2 Channels PC97307 Full duplex asynchronous 50 b s 115 2 KB s RS232 level 2 Channels Z85230 ESCC Full duplex 50 b s 23...

Страница 48: ...ional unbuffered TTL Transfer Rate max 2 MB s 4 10 MTBF Values Includes one 64 Mbyte SODIMM 18900 h computed after MIL HDBK 217E 253270 h realistic value from industry stand experience 4 11 ESD Values...

Страница 49: ...4 13 Maximum Operating Humidity 85 relative 4 14 Power Requi ements r Total Power Requirements without PCI extensions 3 8 A max 3 0 A typ 5 VDC 5 100 mA max 30 mA typ 12 VDC 10 100 mA max 10 mA typ 12...

Страница 50: ...Board Parameters Board Parameters User s Manual BAB 740 4 8...

Страница 51: ...n board Jumpers Figure 3 Parts Side Jumpers X2201 X2202 X701 X702 J1901 J1902 X1301 J2203 J2204 X2001 X2001 J1201 J114 J1302 J1601 J1706 J1301 J1705 J1704 J1703 J1702 J1701 J2201 J2202 X201 X202 X203...

Страница 52: ...2 J101 J602 J601 J603 J111 J112 J113 J107 J108 J109 J110 5 1 1 User settable Jumpers Table 20 Boot ROM Select J114 J114 Description open Boot from Boot ROM Short Boot from User ROM default Table 21 SC...

Страница 53: ...0 to PCI IRQ A 2 3 route Universe INT1 to PCI IRQ A J1703 Function no Universe INT2 INT3 on PCI 1 2 route Universe INT2 to PCI IRQ B 2 3 route Universe INT3 to PCI IRQ B J1704 Function no Universe INT...

Страница 54: ...01 J2201 J2202 X2201 Configuration 1 2 1 2 SILC 200 RS232 async 3 5 5 6 default 6 8 2 4 1 2 SILC 200 RS232 sync 6 8 4 6 6 8 1 2 SILC 300 RS422 async 4 6 2 4 SILC 300 RS422 sync Table 27 COM4 Configura...

Страница 55: ...Jumpers Jumpers User s Manual BAB 740 5 5 5 2 PMCE 740 Jumpers Figure 5 PMCE 740 Jumpers SLOT 1 SLOT 0 X403 X201 X101 X203 X102 X103 X202 R101 R102 R103 R104 J201 J202 J204 X402 X401...

Страница 56: ...MC Slot 0 3 4 3 4 Use PCIREQ PCIGNT of BAB 740 Onboard SCSI Controller Warning PCIREQ and PCIGNT of PMC Slot 0 or SCSI Controller can only be used if the corresponding device is not equipped Table 29...

Страница 57: ...ng SPD of bank2 3 FAILED Activating 64 MByte PowerPC 74x 75x Ver 0008 Rev 3202 at 292 83 MHz PCI devices on local bus No VendorId DeviceId Device Class Sub Class ______________________________________...

Страница 58: ...1st level cache OK Setting MPC106 register OK Reading SPD of bank0 1 OK RAM Type SDRAM Reading SPD of bank2 3 FAILED Activating 32 MByte OS 9000 Bootstrap for the PowerPC tm Ethernet 10 Mbit selected...

Страница 59: ...his case Select a boot method from the above menu eb Bootp sending bootp request for Address 00 00 5b 00 37 39 Bootp Got Response from server c2 00 00 38 My IP Address will be c2 00 00 b8 My Bootfile...

Страница 60: ...Booting Booting User s Manual BAB 740 6 4...

Страница 61: ...no need to address these devices with user written code 7 1 1 SMI Ticker The output of counter timer 2 of the W83C553F may be routed to the System Management Interrupt input of the CPU when J1701 is s...

Страница 62: ...e Register SMI Status register D7 D6 D5 D4 D3 D2 D1 D0 SMIPE Read SMISR I O Address 808 SMIPE 0 no SMI pending SMIPE 1 SMI pending Write Clears pending SMI Register SMI Status register D7 D6 D5 D4 D3...

Страница 63: ...transfer rates up to 3 MBaud synchronous and 230 4 KBaud asynchronous Channel A can be operated with DMA to reduce interrupt load of the CPU for synchronous block protocols DMA channel 0 is used for...

Страница 64: ...W83C553 PCI INT A INT B INT C INT D Super I O PC97307 INT 1 3 12 14 15 INT 9 INT 5 PMC 1 ESCC Z85230 RTC MK48T59 PMC 2 SCSI Network VME This diagram shows how the on board interrupt sources are connec...

Страница 65: ...NT 7 Parallel Port 7 1 4 SRAM RTC A indirect addressing scheme is used to access the M48T59Y SRAM RTC To access the SRAM RTC the desired address first must be written to I O address 70 and 71 Then the...

Страница 66: ...MM ELTEC Revision EEPROM GPIO16 O I2C Clock for SPD of 1st SODIMM ELTEC Revision EEPROM GPIO17 not used GPIO20 not used GPIO21 not used GPIO22 not used GPIO23 not used GPIO24 I HEX Switch LSB GPIO25 I...

Страница 67: ...r 081 082 W83C553F DMA Page 087 W83C553F DMA Page 089 08B W83C553F DMA Page 092 W83C553F Port 92 0A0 0A1 W83C553F Interrupt Controller 2 0C0 0DE W83C553F DMA Controller 2 15C PC97307 SuperI O Index 15...

Страница 68: ...FFF PCI I O space FE81 0000 FE81 FFFF 0081 0000 0081 FFFF PCI I O space SCSI Controller FE82 0000 FE82 FFFF 0082 0000 0082 FFFF PCI I O space LAN Controller FE83 0000 FEBF FFFF 0083 0000 00BF FFFF PCI...

Страница 69: ...M53C860 14 AD 14 21143 15 AD 15 PMC Slot 0 16 AD 16 PMC Slot 1 30 AD 30 Universe II Note that the device numbers differ from Intel convention where number 0 corresponds to AD 11 and number 20 correspo...

Страница 70: ...rt short short x 3 40 83 short short x 5 5 25 40 short short x 4 33 66 default short x 5 25 50 short short short x 6 25 40 short x 3 5 40 75 off off SMD jumper for factory use only Note Implementation...

Страница 71: ...ault short short x 2 33 50 16 25 short short x 2 5 83 33 short x 2 5 41 50 16 20 short short short x 3 75 100 25 33 short short x 3 50 16 short short short short short short short off SMD jumper for f...

Страница 72: ...dware Debugger Configuration J1301 J1301 Operation 1 2 normal operation default 2 3 enable COP Note Implementation specific settings do not change Table 45 Revision EEPROM Write Protection J1302 J1302...

Страница 73: ...e Boot configuration ftp bootp Host Configuration Ethernet IP address Development tool revision VxWorks OS 9 Operating system and revision WinNT Error Description What must be done to reproduce the er...

Страница 74: ...NOTES...

Отзывы: