2 PRECAUTIONS

WARNING

Make sure that the mains supply to the unit is disconnected before performing any installation, service, maintenance or 

electrical work!

WARNING

The installation and service of the unit and complete ventilation system must be performed by an authorized installer and in 

accordance with local rules and regulations.

TRANSPORT AND STORAGE

• Do not leave the device exposed to atmospheric agents (rain, sun, snow, etc.).

• Duct connections/duct ends must be covered during storage and installation.

INSTALLATION 

• After removing the product from its packaging, verify its conditions. Do not leave packaging within the reach of children or 

people with disabilities.

• Beware of sharp edges. Use protective gloves.

• The device should not be used as an activator for water heaters, stoves, etc., nor should it discharge into hot air/fume vent ducts 

deriving from any type of combustion unit or tumble dryer. It must expel air outside via its own special duct.

• If the environment in which the product is installed also houses a fuel-operating device (water heater, methane stove etc., that 

is not a “sealed chamber” type), it is essential to ensure adequate air intake, to ensure good combustion and proper equipment 

operation.

• The electrical system to which the device is connected must comply with local regulations.

•Before connecting the product to the power supply or the power outlet, ensure that:

  - the data plate (voltage and frequency) correspond to those of the electrical mains

  - the electrical power supply/socket is adequate for maximum device power.

• For installation an omnipolar switch should be incorporated in the fixed wiring, in accordance with the wiring rules, to provide 

a full disconnection under overvoltage category III conditions (contact opening distance equal to or greater than 3mm).

USE

• The device should not be used for applications other than those specified in this manual.

• This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental 

capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the 

appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user 

maintenance shall not be made by children without supervision. 

• Do not touch the appliance with wet or damp hands/feet.

• The  device  is  designed  to  extract  clean  air  only,  i.e.  without  grease,  soot,  chemical  or  corrosive  agents,  or  flammable  or 

explosive mixtures. 

• Do not use the product in the presence of inflammable vapours, such as alcohol, insecticides, gasoline, etc.

• 

The system should operate continuously, and only be stopped for maintenance/service.

• Do not obstruct ducts or grilles to ensure optimum air passage.

• Do not immerse the device or its parts in water or other liquids.

SERVICE

• Although the mains supply to the unit has been disconnected there is still risk for injury due to rotating parts that have not come 

to a complete standstill.

• Beware of sharp edges. Use protective gloves.

• Use original spare parts only for repairs.

3 PRODUCT INFORMATION

3.1 General

This is the Installation Manual of VIGO350A heat recovery ventilation unit.

This manual consists of basic information and recommendations concerning installation, commissioning, use and service 

operations to ensure a proper fail-free operation of the unit.

The key to proper, safe and smooth operation of the unit is to read this manual thoroughly, use the unit according to given 

guidelines and follow all safety requirements.

The VIGO350A is supplied with its CTRL-DSP remote multifunction control panel as standard. The package also includes 2 

condensation elbows and 2 plugs for the water drainage.

WARNING

If any abnormality in operation is detected, disconnect the device from the mains supply and contact a qualified technician 

immediately.

Содержание VIGO350A

Страница 1: ...Maintenance 18 8 4 Service 19 8 5 Trouble shooting 20 1 INDEX Installation Manual installer user VIGO350A Heat Recovery Ventilation Unit The VIGO 350A is continuously running Mechanical Ventilation wi...

Страница 2: ...applications other than those specified in this manual This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of e...

Страница 3: ...o outside Supply air to inside Extract air from inside Winter condensation drainage Summer condensation drainage A B D C F E LEFT Connections from and to outside are set on the left side of the unit f...

Страница 4: ...rding to these instructions 5 1 Unpacking Verify that the unit and eventual accessories delivered is according to order before starting the installation Any discrepancies from the ordered equipment mu...

Страница 5: ...The unit must be installed in the following position It is important that the unit is vertical in order for the condensation drainage to work properly Fig 5 a Fig 5 c Fig 5 d Fig 5 f Fig 5 e 517 mm Sp...

Страница 6: ...on used hole with the 2 supplied plugs one each side of the hole Make sure of water and air tightness of all connections It is necessary to use a dry trap or similar in the condensation drainage pipe...

Страница 7: ...ns SLAVE input 1 10V J2 jumper for SLAVE mode AC power supply Heat output max 250Vac 5A Dehumidifier output max 250Vac 5A Boost momentary switch BST IAQ input Air Quality i e SEN CO2 HY input i e SEN...

Страница 8: ...6 0 90 300 m h 250 m h ESTERNO INTERNO 50 m h 100 m h 150 m h 200 m h 6 COMMISSIONING 6 1 Setting Fan speed The speed of the unit can be adjusted during installation according to required ventilation...

Страница 9: ...m Intake 83 65 70 73 62 58 53 47 84 51 Supply 81 65 65 66 57 51 42 33 81 45 Extract 80 63 66 68 60 54 45 34 78 47 Exhaust 78 65 70 71 62 59 53 45 80 50 Breakout 81 69 67 69 62 56 48 36 82 48 80 Lw dB...

Страница 10: ...previous menu OK key to enter the selected menu to go DOWN with the menu selection to go UP with the menu selection to power off the ventilation unit shows ERROR ALARM see point 7 3 to check the type...

Страница 11: ...at speed 1 Press ESC or wait for about 60 sec to go back to the operation screen Fig 7 c In case of activation of either HY or IAQ sensor inputs OR logic the unit speed increases by 15 and the sensor...

Страница 12: ...ion to be set Press OK to select The factory setting DEFAULT is 15 Time options are 15 30 45 60 Time is flashing use increase the time and to decrease Press OK to select User menu 1 Mode Selection 2 B...

Страница 13: ...hine orientation 4 Bypass settings 5 Heating 6 Heating Threshold 7 Dehumidification 8 Speed Setting 9 Airflow Balancing 10 F7 filter 11 Filter Alarm interval 12 Working Hours Counter 13 Save settings...

Страница 14: ...intalled at intake air side Fig 7 a HEAT output Fig 5 g is activated and heating icon displays on LCD when T21 HEATING THRESHOLD Fig 7 a POST the heating element is intalled at supply air side Fig 7 a...

Страница 15: ...ng Threshold 7 Dehumidification 8 Speed Setting 9 Airflow Balancing 10 F7 filter Installer menu 11 Filter Alarm interval 12 Working Hours Counter 13 Save settings 14 Load settings 15 Restore Default S...

Страница 16: ...The VIGO350A is equipped with a physical bypass which mitigates the heat exchange when the indoor and outdoor temperature combinations are such that the heat exchange is not recommended In this case t...

Страница 17: ...The motor bearings are life time lubricated and maintenance free It is possible to easily disconnect and replace the fans if necessary Filters The filters are of filter quality G4 for both the supply...

Страница 18: ...and external environmental conditions Press FILTER button Fig 7 b to reset the Filter Alarm Filters must be replaced every year Clean the heat exchanger every year with a vacuum cleaner This may diffe...

Страница 19: ...19 Fig 8 m Fig 8 k Fig 8 i Fig 8 h Fig 8 n Fig 8 o Fig 8 l Fig 8 j Fig 8 p Fig 8 r Fig 8 q Fig 8 s Fig 8 t...

Страница 20: ...lters required 4 Check ducting system and grilles and diffusers Cleaning required Water leakage near the unit 1 Drain connections and elbows plugs have not been installed correctly Sealing necessary 2...

Страница 21: ...demand control Manual control no DCV o1 Maximum internal leakage rate 1 5 o2 Maximum external leakage rate 1 5 p1 Internal mixing rate N A p2 External mixing rate N A q Visual filter warning Visual fi...

Страница 22: ...s and labour following this period the warranty covers replacement parts only based on maintenance having being carried out in accordance with our literature and terms and conditions of sale Proof of...

Страница 23: ...23 NOTES...

Страница 24: ...001500 04 0818 Elta Fans Limited Building Services 46 Third Avenue Pensnett Trading Estate Kingswinford West Midlands DY6 7US United Kingdom T 44 0 1384 275800 F 44 0 1384 275810 E bs eltafans co uk...

Отзывы: