Elsys EMS Door Скачать руководство пользователя страница 15

 

15 

Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden 
E-mail

[email protected]

 

ǀ

 Web

www.elsys.se

 

Caution 

This device complies with Part 15 of the FCC Rules. Operation is subject to the 
following two conditions: 

(1) This device may not cause harmful interference, and (2) this device must 
accept any interference received, including interference that may cause undesired 
operation. 

This device and its antenna(s) must not be co-located or operating in 
conjunction with any other antenna or transmitter except in accordance with FCC 
multi-transmitter product procedures. 
 

Industry Canada Statement 

This device complies with Industry Canada license-exempt RSS standard(s). 
Operation is subject to the following two conditions: 

(1) this device may not cause interference, and 

(2) this device must accept any interference, including interference that may 
cause undesired operation of the device. 
 

Declaration of conformity 

Hereby, Elektroniksystem i Ume

å

 

AB declares that ERS complies with the 

essential requirements and other relevant provisions of Directive 1999/5/EC. 

Содержание EMS Door

Страница 1: ...ektroniksystem i Umeå AB Industrivägen 12 90130 Umeå Sweden E mail support elsys se ǀ Web www elsys se Specifications in this document are subject to change without notice Elektroniksystem i Umeå AB 2019 ...

Страница 2: ... battery should be removed from the device if it is not to be used for an extended period Otherwise the battery might leak and damage the device Never leave a discharged battery in the battery compartment The device must never be subjected to shocks or impacts To clean the device wipe with a soft moistened cloth Use another soft dry cloth to wipe dry Do not use any detergent or alcohol to clean th...

Страница 3: ... 8 Over the air configuration 8 Application parameters 8 Sensor behavior 9 NFC Read Write 9 Sensor startup 10 Sampling mode Periodic measurement 11 Schedule Transmission 11 Opening activity Reed switch 12 Specifications 13 Sensor payload format 13 Regulations 14 Legal Notices 14 Federal Communication Commission Interference Statement 14 Non modifications Statement 14 Caution 15 Industry Canada Sta...

Страница 4: ...esigned to function as an opening activity sensor It will detect when an object has been opened or moved The small size is ideal for mounting on door frames windowpanes cabinets and much more This is a two piece device with one sensor and one smaller magnet EMS Door is equipped with NFC Near Field Communication and can easily be configured from a smartphone The barcode contains DevEUI and sensor t...

Страница 5: ...ion Detects opening activity Reed Switch Easy installation Easy configuration May be installed on any flat surface Battery powered Long range communication Configurable over NFC Configurable over the air Ten years of battery life Supported channel plans US902 928 EU863 870 AS923 AU915 928 KR920 923 RU864 IN865 HK923 CE Approved and RoHS compliant Depending on settings and environmental factors ...

Страница 6: ...tall the battery The EMS requires one AA battery The battery type is 3 6V Lithium Battery ER14505 Caution Using a battery other than the one provided may result in loss of performance and battery life and also damage to the device Dispose of properly observing environmental protection rules 3 Mount the back panel on the surface using the adhesive tape 4 Attach the cover to the back panel ...

Страница 7: ...he frame For double doors put one part on each door see image The reed switch is on the end of the sensor without the stripe The magnet needs to face this side of the sensor see image The distance between magnet and sensor should if possible not exceed 10mm Make sure that the magnet and reed switch are mounted next to each other Detection range will be affected by the materials of the door and fra...

Страница 8: ... device on top of the EMS sensor to connect with the NFC antenna You may need to remove the top cover and battery to get connection 4 Remove the device Current settings will be displayed in the application 5 Use the application to change any settings if needed 6 Quickly tap the device on top of the EMS to give the new settings to the sensor Make sure that the application confirms your new settings...

Страница 9: ...the sensor reboots and starts from power up 3 Write your settings in the application and then locate the NFC antenna of the phone and sensor Keep the two devices close and don t move them to get the best connectivity as possible when writing or reading data to the sensor Bad connection can be caused by long distance wrong location or rapid movement 4 When you have written data to the sensor let th...

Страница 10: ... NFC chip when something changes in the sensor or if NFC data is corrupted by an NFC writer or phone The sensor always writes the new configuration to NFC chip at startup 3 When the configuration is done the sensor tries to join the network if OTAA Over the Air Activation is enabled 4 The sensor LED flashes orange when it tries to join a network It will try to join every 10 seconds initially This ...

Страница 11: ...Umeå Sweden E mail support elsys se ǀ Web www elsys se Sampling mode Periodic measurement The sensor makes periodic measurements according to the user configurations Schedule Transmission The sensor transmits the data according to the user configurations ...

Страница 12: ...activity is added to a pulse counter that keeps track of the number of opening events The number of the pulse counter and the current state is added to the data packet If the state is changed from open to closed the pulse counter remains unchanged and only the state and current number of counts is added to the data packet After values has been added to the packet the EMS schedules a transmission ...

Страница 13: ... compliance RoHS 2011 65 EU WEEE 2012 19 EU Radio protocol LoRaWAN Radio frequency band US902 928 EU863 870 AS923 AU915 928 KR920 923 RU864 IN865 HK923 Range 8 km Operating conditions 0 to 40 C 0 to 85 RH non condensing Accelerometer detection level Configurable via NFC and downlink conf Dimensions 21 2 x 74 9 x 21 8 mm Battery life Up to 10 years Measured with settings SF10 868 Mhz The range can ...

Страница 14: ...able protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interf...

Страница 15: ...co located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi transmitter product procedures Industry Canada Statement This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interfe...

Отзывы: