Elster NV/SA
Rijkmakerlaan 9
2910 Essen,
Belgium
T + 32 3 670 0700
www.elster-instromet.com
DOCUMENT TITLE
ULTRASONIC FLOWMETER SERIES 6, MODELS Q.SONIC
PLUS
SUBTITLE
QUICK START MANUAL
DOCUMENT NUMBER
22.100.200.000.02/2
REVISION
B
REVISION DATE
2013-02-22
This reproduction is sole property of Elster NV/SA and is subject to the conditions that it or any information contained therein will not be used in any way
detrimental to our interests and that all copies will be returned immediately on demand
PAGE
13 OF 29
22.100.200.000.02_2_B ULTRASONIC FLOWMETER SERIES 6.DOC
Classification: Ex d ia [ia] IIB+H2 T6 Gb IP66
-50 °C < Tamb < +60 °C
ATEX markings:
II 2 G
0344
o
0344 is the NoBo no. of DEKRA Certification B.V.
ATEX certificate reference: DEKRA 11ATEX0170 X
Warning: Read instruction manual before operating device
Figure 10: example ATEX label
4.6.2.
IECEx certified
The explosion proof housing has following IECEx certification information:
Classification: Ex d ia [ia] IIB+H2 T6 Gb IP66
-40 °C
≤
Tamb
≤
+60 °C
IECEx certificate reference: IECE DEK11.0062 X
Warning: Read instruction manual before operating device.
Figure 11: example IECEx label
4.6.3.
FM certified
The explosion proof housing has following FM certification information:
•
Explosionproof for Class I, Division 1, Group A, B, C and D
•
Intrinsically safe for Class I, Division 1, Group A, B, C and D
•
Ta = -40 °F to 140 °F (-40 °C to +60 °C), T6
•
Type 4X
•
“FM approved” mark
Installation requirement: Seal fitting required within 1.5 inches of enclosure
Warning: Read instruction manual (control drawing: 03.304.001.003.05/2) before
operating device. See safety instructions (doc. code: 22.100.200.001/02/2 latest valid