Contents
General information
4
STL-test 17
Service 17
By date
17
After operating hours
17
Delete the displayed maintenance message
17
Reset …
17
Expert area
18
Code-No input
18
System configuration
18
Change code
18
BUS ID 1 / 2 (Heating circuit number)
18
BUS Termination (bus termination resistor)
18
eBUS Supply (supply for eBUS)
18
Time Master
18
Plant Select
(selecting basic controller functions)
18
HS1 Type (first heat generator type)
18
HS1 BUS (connection for HS)
18
HS2 Type (second heat generator type => A7) 19
Storage HS2 (heat accumulator for HS2)
19
Buffer type (heater buffer storage type)
19
Cool Operation
(Space cooling via operating mode)
19
F15 function (sensor function for F15)
19
Set values for heat generators
20
Max T-HS1 (Max. temperature Boiler)
20
Min T-HS1/2 (min temperature Boiler)
20
Max/Min T-Header (only for cascade)
20
Protection from condensate
20
Warm Up Temp
20
Min Delimi (minimum delimiter HS)
20
Hysteresis with hysteresis time
20
Time Seq-Mod (time to sequence change)
21
Block-Time (delay time for next stage)
21
Hyst Burner 2 (for solid fuel / 2nd burner)
21
Gradient method
21
Gradient 21
Max reduce
21
Dyn cutoff
21
HS emergency cooling
21
HS Cool-fct (activation of the emergency
cooling function for HS)
21
with T-HS Cool
(starting temperature for cooling)
21
Switching pattern for 2-stage burners
22
Switching behaviour of the HS with
gradient method
22
Set values for cascade control
23
Enrolment HS
23
Detected HSS (number of heat generators)
23
Capacity / Stage
(heat generator output for each stage)
23
BUS Scan
23
min Mod Cascade (min. modulation cascade) 23
DHW HS (number of stages for HW operation) 23
Control Deviation (collector control deviation) 23
Desired Output (required system output [in %]) 23
Switch Value (-99 – +99)
24
Block Time (currently remaining value)
24
Max T-Module
(maximum temperature of the boiler)
24
Dyn Upward
(dyn. heat generator connection [K])
24
Dyn Downward
(dynamic heat generator deactivation [K])
24
Reset Time (reset time for I-Control)
24
Modulation Max
24
Modulation Min
24
Min Mod HS
24
Modulat DHW (only for HW modules)
24
Sequence 1
24
Sequence 2
24
Sequ Change (type of sequence change)
24
Time Seq-Mod *) (time to sequence change) 24
Block-Time *) (delay time for next stage)
24
Set values for modulation control
25
Min Mod HS
25
Dyn Upward
(dyn. heat generator connection [K])
25
Dyn Downward
(dynamic heat generator deactivation [K])
25
Set values for buffer storage
25
T-Buffer Charge
25
Min T-Buffer
25
Set values for cooling mode
26
T-Return cooling
26
Set values for 0-10V Input / Output
26
V-Curve (only for 0-10V input/output)
26
Curve 11-xx (only when V-Curve = 11)
26
Screed program
27
Preset values
27
Screed (activation of screed drying process)
27
Screed Program (settings)
27
Hot-Water 28
DHW Relief (DHW Relief)
28
Parallel DHW (Pump parallel running)
28
T-HS DHW (increase during HW operation)
28
Hysteresis DHW (hot water hysteresis)
28
DHW Followup (pump run-down time)
28
Therm Input (storage tank with thermostat)
28
Wall Hung (for modulating HS)
28
Load Through (only with F12 = T-DHW B)
28
Heatcircuit 1 / 2
29
HC Function (heating circuit function selection) 29
Pump Mode (pump operating modes)
29
Mixer Open (open mixer dynamic)
30
Mixer Close (close mixer dynamic)
30
Max T-Flow (max. flow temperature)
30
Min T-Flow (min. flow temperature)
30
T-Flow cooling
(only in installation cooling mode)
30
T-Frost protect (frost protection temperature) 30
Outdoor delay (outside temperature delay)
30
Slope Offset (heating slope distance)
30
B-Heat Sink (circuit enable)
30
Auxiliary relay functions
31
Solar/MF 31
MF (1-4) Func (function selection relay MF)
31
T-MF(1-4) Setpoint
(switching temperature relay MF)
33
MF (1-4) Hyst (Switch on hysteresis Relay MF) 33
MF (1-4) Hyst Off
(Switch off hysteresis Relay MF)
33
Solar parameters
34
Max T-Solar
34
Min T-Solar ON
34
Min T-Solar OFF
34
T-Solar protect
34