Operation
6.3.4 Meaning of the status symbols
The status symbols displayed in the first row have the following meaning:
Ill. 21: Status symbols in the display
Symbol
Meaning
At the top left edge of the display, individual letters are displayed as symbols
for the following messages:
ok.
No special messages
A
Alarm – collective message "any alarm"
p
Pressure alarm – the gas pressure cannot be measured
T
Temperature alarm – the gas temperature cannot be measured
W
Warning – collective message "any warning"
B
Battery warning – the battery is nearly empty
L
12
Certification data log - the certification data log is full.
P
Calibration lock (programming mode) – the calibration lock is open.
o
online – data transmission is ongoing
If one of these letters flashes, the condition thereby indicated is still in place (active). If a
letter is displayed consistently, the indicated status is no longer in place, but needs to be
confirmed.
Detailed explanations on the meaning and on any necessary procedure: see chapter 8.1.4
"Conduct in the
Frz.
Display frozen
The values displayed are "frozen" (not up to date). After pressing any key,
the current values are displayed. Freezing the display can be triggered after
pressing the
+
key combination.
12
If a calibration logbook is available in the device.
Содержание EK205
Страница 1: ...Operating manual Volume conversion device EK205 ...
Страница 6: ......
Страница 64: ...64 Appendix 9 2 Conformity declarations19 19 IECEx is not available for all device types ...
Страница 65: ...Appendix 65 9 3 Design test certifications 9 3 1 ATEX EC Type Examination Certificat ...
Страница 66: ...66 Appendix ...
Страница 67: ...Appendix 67 ...
Страница 68: ...68 Appendix 9 3 2 IECEx Certificate of Conformity20 20 Not available for all device types ...
Страница 69: ...Appendix 69 ...
Страница 70: ...70 Appendix ...
Страница 71: ...Appendix 71 ...