Installation
4
Page 18 of 38
Safety Instructions
UFM Series 6
WARNING!
Do not perform any modification of the products supplied.
The volume of the SPU enclosure to fit user glands is
less than 2 liters.
Unused gland entries must be fitted with suitable certified
stopping plugs.
Before use ensure unused entries contain suitable
certified plugs (and not temporary or transportation
plugs).
The connection between each gland or stopping plug
and the enclosure must comply with the NEMA or IP
class and the temperatures indicated on the SPU (e.g. by
using a suitable IP washer).
During transport and storage the electronics enclosure
back and main compartment may contain a bag of silica
gel to absorb excessive humidity. Remove the bags
before powering the SPU.
4.3 System Specifications
Power connection (TB1):
18 – 30VDC, 20 Watt maximum. 24 V Nominal.
Cable max. 700m, max. 5 Ohm/wire
Built-in surge protection
Maximum cable core 2.5 mm
2