Elson coral e Скачать руководство пользователя страница 8

In accordance with our policy of continual product improvement, we
reserve the right to amend the specification of these products without
prior notification.

© Elsy & Gibbons Limited 2004.
All rights reserved. No part of this manual may be reproduced by any
means without prior written consent.

Manual compiled and designed by Publications 2000.  Tel 01670 356211

08/04/D64

Elsy & Gibbons,
Simonside
South Shields,
Tyne and Wear NE34 9PE
Telephone: 0191 427 0777
Facsimile: 0191 427 0888

www.elsonhotwater.co.uk

TO BE COMPLETED BY THE INSTALLER

1.

Product serial No. ...........................................................................................................

2.

Installation date ..............................................................................................................

3.

Name of Installer ............................................................................................................

Address ..........................................................................................................................

........................................................................................................................................

........................................................................................................................................

Telephone No. .................................................................................................................

4.

Type of controller fitted ...................................................................................................

5.

Details of supply tariff .....................................................................................................

6.

Is a scale reducer fitted?

Yes/No

Details .........................................................

7.

Is a Y type line strainer fitted?

Yes/No

Details .........................................................

10. ELSON CORAL E USER'S INSTRUCTIONS

1.

Your hot water system is designed to provide mains pressure hot water to all outlets including showers,
turning an ordinary shower unit into a 'Power Shower' without the need for expensive pumps.

2.

The temperature of the hot water supplied to your taps can be adjusted from 35° to 55°C by adjusting the
blending valve on the top of the unit. See section 5.2 on page 5. The temperature is factory set to approximately
50°C.

3.

The Coral E is designed to make the most of low price off-peak electricity, you should contact your electricity
supplier, asking for details of your particular supply and advice for economical use.

4.

For the most economical use of the Coral E you should restrict your main use of hot water (baths etc.) to such
a time that the water in the unit will be re-heated during the off-peak period.

5.

IMPORTANT: The 'Boost' immersion heater fitted to the Coral E operates on full price electricity, it should
therefore be used sparingly and always switched off after use. A runback timer should have been fitted when
the unit was installed.

6.

The Coral E is fitted with a safety overheat limit thermostat, see Fig. 2, which will automatically switch off the
'Overnight' immersion heater in the case of a control thermostat malfunction causing overheating. If you find
the tank is cold in the morning, press the reset button (use the end of a pen or pencil) on the limit thermostat
to reset it and the tank should be reheated overnight as normal. If you require hot water sooner, use the 'Boost'
immersion heater to heat the water (see note 5 above).

If the limit thermostat needs to be continually reset, contact your Installer.

7.

When running a bath, you can increase the temperature and volume of water by reducing the flow rate at the
tap, i.e. do not open it fully.

8.

When cleaning the Coral E do not use abrasive cleaners on the white metal cased models or wet cloths on the
hardboard cased models.

Содержание coral e

Страница 1: ...e instructions with the User ForTechnical Help or Sales queries contact 0191 4270777 COMPLIES WITH PART L BUILDING REGULATIONS Elson is a member of the Benchmark initiative and fully supports the aims of the programme Benchmark has been introduced to improve the standards of installation and commissioning of central heating systems in the UK and to encourage the regular servicing of all central he...

Страница 2: ...ng the blending valve see section 5 2 The blending valve is fail safe in the event of a mains water supply failure The unit is designed to provide maximum performance and efficiency with the thermal store being heated overnight via the bottom immersion heater using the low price off peak tariff The top immersion heater used for daytime Boost is fitted directly underneath the coils allowing for fas...

Страница 3: ...event of thermostat failure therefore preventing permanent damage to the unit Note If a runback timer is not fitted and the unit is damaged due to boiling the damage will not be covered by the product guarantee 3 For optimum performance we recommend a dedicated 22 mm mains cold water supply to the unit and a 15 mm hot water outlet If the mains cold water supply pressure is less than 1 bar we recom...

Страница 4: ...recommended 4 2 Electrical connection Refer to wiring diagrams in section 8 All electrical wiring must be carried out by a qualified electrician and must be in accordance with BS 7671 Regulations for Electrical Installations IEE Wiring Regulations and any local regulations which apply The mains supply required is 230 240 V 50 Hz each heater fused at 13 A Ensure the electricity supply has been isol...

Страница 5: ...work turn on the mains water supply and the thermal store will fill with water via the internal feed and expansion tank 2 Vent the hot water pipework by opening a hot tap 3 Check the immersion heaters and all connections for water soundness rectifying where necessary 4 Check the water level in the feed and expansion tank is to the marked water line If necessary adjust the float operated ball valve...

Страница 6: ...ssemble the valve and re set the temperature as described in section 5 2 6 2 To replace the overheat limit thermostat 1 Switch off the electricity supply to the unit 2 Remove the four screws securing the lower immersion heater cover and lift off the cover 3 Disconnect the two leads from the thermostat positioned above the immersion heater and remove the two fixings securing the thermostat Take car...

Страница 7: ...ermostat EP051016 Standard immersion heater complete 2 off 90100001 Blending valve complete EP100071 Runback timer EP09101 Part No 7 SPARE PARTS LIST The following specialist spare parts for the Coral E are readily available from Elsy Gibbons Limited 7 Check that the control thermostat setting is correct for maximum performance top at 75 C and bottom at 85 C The bottom thermostat may have been red...

Страница 8: ...d to make the most of low price off peak electricity you should contact your electricity supplier asking for details of your particular supply and advice for economical use 4 For the most economical use of the Coral E you should restrict your main use of hot water baths etc to such a time that the water in the unit will be re heated during the off peak period 5 IMPORTANT The Boost immersion heater...