3. TECHNICAL DATA

Connections

Frame size (mm) of WMF models is 730 wide, 660 deep and 915 high.

Frame size (mm) of 150 EBF/SS model is 600 wide, 600 deep and 1080 high.
Frame size (mm) of 210 EBF/SS model is 650 wide, 650 deep and 1080 high. All frame weights are approximately 14 kg.

Heat loss exceeds the requirements of BS 3198.

Notes:

i. Allow a minimum of 100 mm on the depth to accommodate the immersion heater covers and plumbing connections.
ii. All models are supplied fitted with two 3 kW Maxistore immersion heaters. The 100 and 150 models can be

supplied with only one immersion heater (bottom) fitted with the other boss plugged, if specified when ordered.

iii. Dimensions shown are for the hardboard cased versions, the white metal cased units are slightly smaller.
iv. All compression fittings are suitable to accept copper tubing to EN 1057.

Graph giving an indication of the minimum hot water performance available

Figures obtained using the store fully

heated to 85°C, with a mains cold water

supply temperature of 10°C and the

following constant draw off rates:-
Coral E 210 - 18 litres/min.

Coral E 150 - 18 litres/min.

Coral E 100 - 12 litres/min.

Volume drawn off (litres)

80

20

260 280 300

220

200

40

180

140

120

60

100

160

240

50

45

Temp

(°C)

40

Coral E 210
Coral E 150
Coral E 100

3.1. Hot water performance

Electricity supply:

230/240 V ~ 50 Hz
(each heater fused at 13 A)

2. IMPORTANT NOTES

1.

The control thermostats on both immersion heaters are factory set for maximum performance (top at 75°C
and bottom at 85°C). The bottom thermostat may be reduced slightly (not below 75°C) where it is known that
hot water demand will not be high.

2.

The top ('Boost') immersion heater must be controlled via a runback timer (one or two hours, preferably one
hour) and not a simple isolating switch. This timer has two purposes, firstly to prevent uneconomical use of full
price electricity and secondly it acts as a form of protection against long periods of boiling in the unlikely event
of thermostat failure, therefore preventing permanent damage to the unit.
Note: If a runback timer is not fitted and the unit is damaged due to boiling, the damage will not be
covered by the product guarantee.

3.

For optimum performance we recommend a dedicated 22 mm mains cold water supply to the unit and a 15 mm hot
water outlet. If the mains cold water supply pressure is less than 1 bar we recommend a 22 mm hot water outlet.

4.

The level of the water in the feed and expansion tank must be set to the waterline mark - it is not factory set.

5.

An isolating valve should be fitted in the mains cold water supply to the unit.

6.

We recommend that a Y type line strainer is fitted in the mains cold water supply to the unit.

7.

We recommend that a scale reducer is fitted on the mains cold water supply prior to the unit. This is especially
important in hard water areas (in-line scale reducers may reduce flow rates).

8.

If a non-return valve is fitted in the mains cold water supply to the unit, provision must be made to accommodate
the increased water volume during the normal heat-up cycle, e.g. a mini expansion vessel with a capacity of
not less than 160 ml (i.e. Zilmet Z160).

9.

The hot water blending valve is factory set to approximately 50°C. For adjustment refer to section 5.2.

10. For installation and servicing requirements, the portion of the work surface above the UWS model must be

removable. The unit may be positioned in a cupboard space beneath the work surface and a door fitted, if
required - allow 100 mm on the depth to accommodate the immersion heater covers and plumbing connections.

100 UWS

100

150

210

300

150 EBF/SS

* 210 EBF/SS

* 150 WMF

210 WMF

100

100

150

210

300

150

210

150

210

571

571

571

571

600

600

650

560

571

750

865

1285

1285

1285

880

940

820

1000

571

495

495

584

700

600

650

730

730

Tank height

mm

Capacity

litres

Tank depth

mm

Heat loss to BS 3198

W/litre (kW/24hrs)

0.44 (1.18)

0.44 (1.18)

0.33 (1.28)

0.27 (1.48)

0.33 (1.28)

0.27 (1.48)

0.33 (1.28)

0.27 (1.48)

Tank width

mm

Coral E

model

Hot water

15 mm comp.

Mains cold water

22 mm comp.

Overflow

22 mm comp.

Immersion heater 2¼" BSP (2 off)

Drain boss

½" BSP

-

-

-

-

-

1960

2020

1735

1915

Total height

with frame mm

Содержание coral e

Страница 1: ...e instructions with the User ForTechnical Help or Sales queries contact 0191 4270777 COMPLIES WITH PART L BUILDING REGULATIONS Elson is a member of the Benchmark initiative and fully supports the aims of the programme Benchmark has been introduced to improve the standards of installation and commissioning of central heating systems in the UK and to encourage the regular servicing of all central he...

Страница 2: ...ng the blending valve see section 5 2 The blending valve is fail safe in the event of a mains water supply failure The unit is designed to provide maximum performance and efficiency with the thermal store being heated overnight via the bottom immersion heater using the low price off peak tariff The top immersion heater used for daytime Boost is fitted directly underneath the coils allowing for fas...

Страница 3: ...event of thermostat failure therefore preventing permanent damage to the unit Note If a runback timer is not fitted and the unit is damaged due to boiling the damage will not be covered by the product guarantee 3 For optimum performance we recommend a dedicated 22 mm mains cold water supply to the unit and a 15 mm hot water outlet If the mains cold water supply pressure is less than 1 bar we recom...

Страница 4: ...recommended 4 2 Electrical connection Refer to wiring diagrams in section 8 All electrical wiring must be carried out by a qualified electrician and must be in accordance with BS 7671 Regulations for Electrical Installations IEE Wiring Regulations and any local regulations which apply The mains supply required is 230 240 V 50 Hz each heater fused at 13 A Ensure the electricity supply has been isol...

Страница 5: ...work turn on the mains water supply and the thermal store will fill with water via the internal feed and expansion tank 2 Vent the hot water pipework by opening a hot tap 3 Check the immersion heaters and all connections for water soundness rectifying where necessary 4 Check the water level in the feed and expansion tank is to the marked water line If necessary adjust the float operated ball valve...

Страница 6: ...ssemble the valve and re set the temperature as described in section 5 2 6 2 To replace the overheat limit thermostat 1 Switch off the electricity supply to the unit 2 Remove the four screws securing the lower immersion heater cover and lift off the cover 3 Disconnect the two leads from the thermostat positioned above the immersion heater and remove the two fixings securing the thermostat Take car...

Страница 7: ...ermostat EP051016 Standard immersion heater complete 2 off 90100001 Blending valve complete EP100071 Runback timer EP09101 Part No 7 SPARE PARTS LIST The following specialist spare parts for the Coral E are readily available from Elsy Gibbons Limited 7 Check that the control thermostat setting is correct for maximum performance top at 75 C and bottom at 85 C The bottom thermostat may have been red...

Страница 8: ...d to make the most of low price off peak electricity you should contact your electricity supplier asking for details of your particular supply and advice for economical use 4 For the most economical use of the Coral E you should restrict your main use of hot water baths etc to such a time that the water in the unit will be re heated during the off peak period 5 IMPORTANT The Boost immersion heater...

Отзывы: