background image

4

Installation and start-up

Motor control unit IMSG230

 • Version: 05.02.2016 • Technical Changes and Errors excepted.

4.

Installation and start-up

4.1. Installation notes

Installation, testing, operational start-up and troubleshooting should 
only be performed by an electrician.

DANGER!
Risk to life from live voltage (mains voltage)! 

There are unprotected live components within the device.

VDE regulations and national regulations are to be followed.

Ensure that all lines to be assembled are free of voltage and take
precautions against accidental switching on.

Do not use the device if it is damaged. 

Take the device or system out of service and secure it against
unintentional use, if it can be assumed, that risk-free operation is no
longer guaranteed.

The device is only to be used for its intended purpose. Any improper modification or
failure to follow the operating instructions voids any and all warranty and guarantee
claims.

After unpacking the device, check it immediately for possible mechanical damage. If it
has been damaged in transport, inform the supplier immediately.

The device may only be used as a fixed-site installation; that means only when
assembled and after conclusion of all installation and operational start-up tasks and
only in the surroundings designated for it.

Elsner Elektronik is not liable for any changes in norms and standards which may occur
after publication of these operating instructions.

Содержание IMSG 230

Страница 1: ...ation in structions Elsner Elektronik GmbH Control and Automation Technology Sohlengrund 16 D 75395 Ostelsheim Phone 49 0 70 33 30 945 0 info elsner elektronik de Germany Fax 49 0 70 33 30 945 20 www...

Страница 2: ...ng a drive position using the manual switch can be recalled by pressing the down button for a longer period 3 6 seconds A position of a shutter or a partially opened window that is often required can...

Страница 3: ...d the IMSG 230 is in normal mode again Note As soon as a central command arrives e g because of a wind or rain alarm the programming mode is interrupted In this case please carry out the position stor...

Страница 4: ...or system out of service and secure it against unintentional use if it can be assumed that risk free operation is no longer guaranteed The device is only to be used for its intended purpose Any improp...

Страница 5: ...G230 Version 05 02 2016 Technical Changes and Errors excepted 4 2 Connection diagram Power supply and central input Drive and push button input Input Central input 230 V A Central command Open Down 23...

Страница 6: ...the Solexa shading control or Arexa window control are suitable for use as central control units 4 4 Example of a central control system with groupings Units such as the Solexa shading control or Are...

Страница 7: ...s required also be used 4 5 Notes on mounting and commissioning Device must not be exposed to water rain This could result in the electronic being damaged A relative air humidity of 95 must not be exc...