Storing a movement position
Motor control unit IMSG230
• Version: 05.02.2016 • Technical Changes and Errors excepted.
•
Move the drive to the starting/zero position, i.e. close the window, retract the
awning or raise the shutter.
•
Press the up and down buttons simultaneously for 3 seconds.
•
As feedback the drive briefly moves up and down. You are in now
programming mode.
•
Move to the desired position.
•
Store the position by pressing the up and down buttons for 1 second
simultaneously.
•
As feedback the drive briefly moves up and down.
•
With blind slats, now open the slats to the desired angle. For windows and
awnings, you can skip this point.
•
Store the position by pressing the up and down buttons again for 1 second
simultaneously.
•
As feedback the drive briefly moves up and down. The storage is complete and
the IMSG 230 is in normal mode again.
Note: As soon as a central command arrives (e.g. because of a wind or rain alarm), the
programming mode is interrupted! In this case, please carry out the position storage
again when the central command is no longer present.
3.1. Technical specification
The following norms were consulted in evaluating this product with respect to electro-
magnetic compatibility:
EN 60730-1:2000-11 + A11:2002
The product was tested by an accredited EMC laboratory in compliance with the above-
named norms.
The product is compliant with the provisions of EU guidelines.
Assembly
Installation
Protection category
IP 20
Dimensions
approx. 38 x 47 x 30 (W x H x D, mm)
Weight
approx. 45 g
Ambient temperature
Operation -20…+70 °C, storage -55…+90°C.
Ambient humidity
max. 95% RH, avoid condensation
Operating voltage
230 V AC, 50 Hz
Inputs
• Operating voltage (Mains L1/N/PE)
• Central commands (central up/down)
• On-site button (button L1 out/up/down)
Output
1 x Drive 230 V (PE/N/down/up), each fused at 4 A T