Installation and commissioning

Ventilation Unit WL610

 • Date of issue: 25.05.2011 • Technical changes reserved. Errors reserved.

After unpacking the device, check immediately for any mechanical damages. In case of
transport damage, this must immediately notified to the supplier.

If damaged, the device must not be put into operation. 

If an operation without risk may supposedly not be guaranteed, the device must be put
out of operation and be secured against accidental operation.

The device must only be operated as stationary system, i.e. only in a fitted state and
after completion of all installation and start-up works, and only in the environment in-
tended for this purpose.

Elsner Elektronik does not assume any liability for changes in standards after publica-
tion of this instruction manual.

2.2. Notes on wireless equipment

When planning facilities with devices that communicate via radio, adequate radio re-
ception must be guaranteed.  The range of wireless control will be limited by legal reg-
ulation and structural circumstances. Avoid sources of interference and obstacles be-
tween receiver and transmitter, that could disturb the wireless communication. Those
would be for example:

Walls and ceilings (especially concrete).

Metal surfaces next to the wireless participants (e. g. aluminium construction 
of a conservatory).

Other wireless devices and powerful local transmitters (e.g. wireless 
headphones), which transmit on the same frequency (868,2 MHz). Please 
maintain a minimum distance of 30 cm between wireless transmitters for that 
reason.

2.3. Notes on mounting

The ventilator panel with the ventilator must be mounted such that the cover hood of
the air intake opening faces inwards.

The inner cover hood is fastened by locks on the ventilator panel. To remove the hood,
loosen the locks on both sides with a screwdriver. The electronic control of the venti-
lator is mounted under the cover hood.

When mounting and before first use, make sure the cover hood 
is firmly fastened to the ventilator panel.

So that no water can penetrate through the air outlet on the outside when it is raining,
or due to other weather influences, the panel must be mounted such that the outlet fac-
es downwards.

Содержание WL610

Страница 1: ...er Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone 49 0 70 56 93 97 0 info elsner elektronik de Germany Fax 49 0 70 56 93 97 20 www elsner elektronik de WL610 Ventilation Unit for air extraction and recirculation Interior view ...

Страница 2: ...ation water The controls register critical conditions of temperature and dew point with the help of a special calculation method and start the ventilation unit in the mayor of cases even bevor humidity precipitates Wireless control without additional device only the power supply has to be connected Quiet lateral blower Highly heat insulating housing consists of integral skin foam Extremely tight c...

Страница 3: ... the precise criteria Required opening for supply air 12 240 mm per WL610 e g two Supply Air Units WFL or equal window opening Sound pressure at 2 m distance max approx 58 6 dB A at full load U value insulating panel 1 03 W m K ventilator total approx 1 8 W m K calculated presup position area ventilator area panel Volumetric weight of insu lating panel 60 kg Compressive strength of panel 350 kPa M...

Страница 4: ...red in side ouside Minimum width approx 840 mm Width of ventilator approx 698 mm plus 50 mm on both sides plus the size required on both sides for installation Minimum depth for shortening approx 580 mm Depth of ventilator approx 360 mm plus 100 mm at the top can not be trimmed plus 100 mm at the bottom plus the size required at the bottom for installation Minimum depth special panel approx 550 mm...

Страница 5: ...only be carried out by a competent electrician Disconnect all lines to be assembled and take safety precautions against accidental switch on The device is exclusively intended for appropriate use With each inappropriate change or non observance of the instructions for use any warranty or guarantee claim will be void Level Flap Blower Extraction 8 opened runs highest speed Extraction 7 opened runs ...

Страница 6: ...reg ulation and structural circumstances Avoid sources of interference and obstacles be tween receiver and transmitter that could disturb the wireless communication Those would be for example Walls and ceilings especially concrete Metal surfaces next to the wireless participants e g aluminium construction of a conservatory Other wireless devices and powerful local transmitters e g wireless headpho...

Страница 7: ...e 25 05 2011 Technical changes reserved Errors reserved 2 4 Device construction Fig 2 1 Outlet cable voltage supply not visible when mounted 2 PCB 3 Ventilation unit with roll ventilator flap and drives 4 Screws M5 Allen 5 Screws M3 Allen 6 Inside cover hood 7 Lock hole ...

Страница 8: ...y be detached No abra sive cleaning agents should be used for cleaning Maintenance and cleaning inside the device must only be car ried out by a competent electrician The device must be separat ed from power supply then e g deactivate or remove fuse Fig 3 Prited circuit board 1 Microfuse T 1 6 A 2 Terminals power supply L N PE 3 Terminals 1 Fan red 2 Fan blue 3 Fan black 4 Not in use 5 Flap drive ...

Отзывы: