background image

KNX RW

Rain/Wind Sensor

Technical specifications and installation instructions

EN

Elsner Elektronik GmbH 

Control and Automation Engineering

Herdweg 7
D – 75391 Gechingen Phone +49 (0) 70 56 / 93 97-0

[email protected]

Germany

Fax

+49 (0) 70 56 / 93 97-20

www.elsner-elektronik.de

KNX RW 24 V

KNX RW 230 V
No. 70126

No. 70127

Содержание KNX RW 70126

Страница 1: ...llation instructions EN Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone 49 0 70 56 93 97 0 info elsner elektronik de Germany Fax 49 0 70 56 93 97 20 www elsner elektronik de KNX RW 24 V KNX RW 230 V No 70126 No 70127 ...

Страница 2: ...3 with adjustable threshold values Threshold values can be set by parameter or via communication objects 8 AND and 8 OR logic gates with each 4 inputs Every switching incident as well as 8 logic inputs in the form of communication objects may be used as inputs for the logic gates The output of each gate may optionally be configured as 1 bit or 2 x 8 bits Configuration is made using the KNX softwar...

Страница 3: ...mbled are free of voltage and take precautions against accidental switching on Do not use the device if it is damaged Take the device or system out of service and secure it against unintentional use if it can be assumed that risk free operation is no longer guaranteed The device is only to be used for its intended purpose Any improper modification or failure to follow the operating instructions vo...

Страница 4: ...uctedly Do not assemble any construction components above the sensor from where water may drop on to the rain and wind sensor after it has stopped raining or snowing At least 60 cm of free space must be left beneath the device to enable correct wind measurement and prevent snowing in when there is snow The distance also protects the unit against damage by birds 2 3 Mounting the sensor 2 3 1 Attach...

Страница 5: ...rent mounting arms are available from El sner Elektronik as additional optional accesso ries for flexible installation of the weather station on a wall pole or beam Example of the use of a mounting arm Due to flexible ball joints the sensor can be brought into ideal position Fig 6 Example use of the hinge arm mounting With the hinge arm mounting the weather sta tion projects from beneath the roof ...

Страница 6: ...eserved Errors reserved 2 3 2 View of rear side and drill hole plan Fig 7 Example use of the hinge arm mounting Fitting to a pole with worm drive hose clips Langloch 7 5 x 5 mm Fig 8 a b Drill hole plan Dimensions of rear side of housing with bracket Sub ject to change for technical enhancement ...

Страница 7: ...e connection in case of 230 V AC version cable with plug in case of 24 V DC version Lead the cable for the voltage supply and bus connection through the rubber seals on the bottom of the device and connect Voltage L N and Bus to the terminals provid ed For 24V devices the connection cable must be plugged in between the cover and circuit board Fig 9 1 Screw on cover 230V device 2 Cover with rain se...

Страница 8: ...Cable connection to the rain sensor in the housing cover 2 Opening for the cable for the voltage supply 3 Tension clamp for voltage supply 230 V AC suitable for massive conductors of up to 1 5 mm or conductors with fine wires 4 Slot for KNX clamp 5 Opening for the bus cable 6 Programming pushbutton for the teach in of the device 7 Programming LED 2 3 4 6 7 5 1 ...

Страница 9: ... to the rain sensor in the housing cover 2 Tension clamp for voltage supply 24 V DC 20 V AC Massive conductors of up to 1 5 mm or conductors with fine wires Terminal configu ration independent from po larity or 3 Opening for the cable for the voltage supply and for bus ca ble 4 Slot for KNX clamp 5 Programming pushbutton for the teach in of the device 6 Programming LED 2 3 1 5 6 4 Fig 13 Make sure...

Страница 10: ...e measured wind value and thus all other wind switching outputs may only be sup plied 60 seconds after the supply voltage has been connected After the auxiliary voltage has been applied the device will enter an initialisation phase lasting a few seconds During this phase no information can be received via the bus 3 Addressing of the device at the bus The device is supplied with the bus address 15 ...

Страница 11: ...so by a jet of water there is the risk of an electric shock with 230 V devices Risk of injury caused by components moved automatically The automatic control can start system components and place people in danger e g moving windows awnings if a rain wind alarm has been triggered while cleaning Always isolate the device from the mains for servicing and cleaning e g switch off or remove the fuse The ...