10
KNX Interface for WS1000
• Status: 15.04.2016 • Errors excepted. Subject to technical changes.
61
Block 7_5: Long-time
Input / Output
1,008
C W T
62
Block 7_5: Short-time
Input / Output
1,01
C W T
63
Block 7_5: Actuation position
Output
5,001
C T
64
Block 7_5: Slat position
Output
5,001
C T
65
Block 7_5: Movement position
feedback
Input
5,001
C W T
66
Block 7_5: Slat position feedback
Input
5,001
C W T
67
Block 7_5: Safety
Output
1,002
C R T
61
Block 7_5: Switching
Output
1,001
C W T
62
Block 7_5: Switching feedback
Input
1,001
C R T
62
Block 7_5: Dimming
Output
3,007
C T
63
Block 7_5: Dimmer value in %
Input / Output
5,001
C W T
65
Block 7_5: Temperature
Input
9,001
C W T
66
Block 7_5: Air humidity
Input
9,007
C W T
67
Block 7_5: CO2
Input
9,008
C W T
67
Block 7_5: 2 byte floating point
Input
9.*
C W T
67
Block 7_5: 4 byte floating point
Input
14.*
C W T
68
Block 7_6: Long-time
Input / Output
1,008
C W T
69
Block 7_6: Short-time
Input / Output
1,01
C W T
70
Block 7_6: Actuation position
Output
5,001
C T
71
Block 7_6: Slat position
Output
5,001
C T
72
Block 7_6: Movement position
feedback
Input
5,001
C W T
73
Block 7_6: Slat position feedback
Input
5,001
C W T
74
Block 7_6: Safety
Output
1,002
C R T
68
Block 7_6: Switching
Output
1,001
C W T
69
Block 7_6: Switching feedback
Input
1,001
C R T
69
Block 7_6: Dimming
Output
3,007
C T
70
Block 7_6: Dimmer value in %
Input / Output
5,001
C W T
72
Block 7_6: Temperature
Input
9,001
C W T
73
Block 7_6: Air humidity
Input
9,007
C W T
74
Block 7_6: CO2
Input
9,008
C W T
74
Block 7_6: 2 byte floating point
Input
9.*
C W T
74
Block 7_6: 4 byte floating point
Input
14.*
C W T
75
Block 7_7: Long-time
Input / Output
1,008
C W T
76
Block 7_7: Short-time
Input / Output
1,01
C W T
77
Block 7_7: Actuation position
Output
5,001
C T
78
Block 7_7: Slat position
Output
5,001
C T
No.
Name
Function
DPT
Flags