Motor control unit IMSG230 compact
1
Motor control unit IMSG230 compact
• Version: 28.05.2020 • Technical changes and errors excepted. • Elsner Elektronik GmbH • Sohlengrund 16 • 75395 Ostelsheim • Germany • www.elsner-elektronik.de •
Technical Service: +49 (0) 7033 / 30945-250
EN
IMSG 230 compact
Motor control unit
1.
Description
The
Motor control unit IMSG230 compact
enables the automatic and manual
control of the drives for blinds or windows. Commands issued at the main input (on/
off) have priority. Switches, clocks etc. can be connected there. The control system
Solexa, Solexa II, Arexa, WS1 or WS1000 are also suitable as main control stations.
For the manual operation of the drive, dual push-buttons are used.
Functions:
•
Output for a
230 V AC drive
(Up/Down)
•
Use as a
central, group and single controller
•
Central input
up/down 230 V (with priority) e.g. for switches, control system
Solexa, Solexa II, Arexa, WS1 or WS1000
•
Setting the central control unit to "Dead man" or "Lock". As long as voltage is
present at the central input, the manual operation is blocked
•
Manual operation
by connecting an unlocked double push-button to the
Input "Local".
Push-button timer automatic: Inching mode (press for less than 1 second):
Drive inches, for example for positioning slats on shutters.
Drive mode (press for longer than 1 second): Drive travels automatically to
the final position
•
Direction change pause 1 second
1.1. Deliverables
•
Motor control unit
1.2. Technical specification
The product is compliant with the provisions of EU guidelines.
2.
Installation and start-up
2.1. Installation notes
Installation, testing, operational start-up and troubleshooting should
only be performed by an electrician.
DANGER!
Risk to life from live voltage (mains voltage)!
There are unprotected live components within the device.
•
VDE regulations and national regulations are to be followed.
•
Ensure that all lines to be assembled are free of voltage and take
precautions against accidental switching on.
•
Do not use the device if it is damaged.
•
Take the device or system out of service and secure it against
unintentional use, if it can be assumed, that risk-free operation is no
longer guaranteed.
The device is only to be used for the intended purpose described in this manual. Any
improper modification or failure to follow the operating instructions voids any and
all warranty and guarantee claims.
After unpacking the device, check it immediately for possible mechanical damage.
If it has been damaged in transport, inform the supplier immediately.
The device may only be used as a fixed-site installation; that means only when
assembled and after conclusion of all installation and operational start-up tasks and
only in the surroundings designated for it.
Elsner Elektronik is not liable for any changes in norms and standards which may
occur after publication of these operating instructions.
2.2. Safety notice for automatic functions
WARNING!
Risk of injury from automatically moving components!
Parts of the system can be started by the automatic controls
and be a danger to persons.
•
No persons may remain in the travelling range of parts
driven by an electric motor.
• Adhere to the relevant building regulations.
•
Ensure that the return path/access to the building is not blocked
if spending time outside the building (danger of being locked out).
•
Correctly decommission the system for maintenance and
cleaning work.
If there is a power outage, the system does not work. Therefore, shadings should be
moved to a save position if there are anticipated weather conditions, for example, if
this has not already been done by the automatic function (product protection).
If the power supply is removed, the connected drive switches off. When the power
is restored, the consumer remains switched off until a new movement command is
received by the actuator.
2.3. Design of the IMSG 230 compact / Connection
Connection diagram 1
Supply via a mains connection
Assembly
Installation
Protection category
IP 20
Dimensions
Ø approx. 53 mm, depth approx. 29 mm
Weight
approx. 80 g
Ambient temperature
Operation -20…+45 °C, storage -55…+90°C.
Ambient humidity
max. 95% RH, avoid condensation
Operating voltage
230 V AC, 50 Hz
Power consumption
Operation maximum 2.0 W
Maximum load
Each terminal contact may be loaded with a
maximum of 10 A.
Central input
1x Central command (L up/L down/N)
Maximum line length 40 m per MSG.
Local input (SELV)
1× present button (Up/Down/+)
Voltage for inputs 12...28 V DC.
Maximum line length 10 m.
Output
1 x Drive 230 V (L/N/down/up)
Lock mode
Command at least 1 s
Travel time 4 min
Direction change pause
1 s
Technical specifications and installation instructions
Item number 70453
Fig. 1
1 Central inputs: L down/N/L up
2 V (12...28 V DC) for in-
puts,
Push-button input local (up/
down)
3 Mode LED
4 Actuator output (down/L/N/up),
Operating voltage (L/N)
1
2
3
4
s
u
d
o
M
+
l
ak
oL
NI
L
N
OUT Motor
IN Zentral
L
N
N
r
N t
är
e
gr
e
u
et
sr
ot
o
M3
54
07
.
IMSG230 compact
L
VL
E
S
230 V AC
N
PE
L
PE
N
Control/
Central
Button local
Mains
230 V AC
further MSGS
Fig. 2
Each terminal
contact may be
loaded with a
maximum of
10 A.