manualshive.com logo in svg
background image

2

Description

Camera Interface for WS1 Color and WS1000 Style

 • Status: 07.03.2016 • Technical Changes and Errors reserved.

1.

Description

The 

Camera Interface for WS1 Color and WS1000 Style

 allows video cameras to

be connected to the control unit. The camera images are shown on the screen.

Functions:

For 2 video cameras

Display of the images on the control unit screen. Camera image can be 
switched on and off via buttons on the screen or via signal in the 
multifunctional input (configuration as binary input)

1.1. Scope of delivery

Interface to be screwed into the screen board of the control unit

1.2. Technical Data

The 

Camera Interface

 is suitable for the WS1 Color or WS1000 Style control with

software 1.492 or higher. The software version is displayed with each start of the con-
trol system (new start in menu: System > WS1 settings > Service > Reset).

The product conforms with the provisions of EU directives.

2.

Installation and Commissioning

2.1. Installation notes

Installation, testing, operational start-up and troubleshooting should 
only be performed by an electrician.

DANGER!
Risk to life from live voltage (mains voltage)! 

There are unprotected live components within the device.

VDE regulations and national regulations are to be followed.

Ensure that all lines to be assembled are free of voltage and take
precautions against accidental switching on.

Installation

to be screwed into the screen board on the control unit

Dimensions

approx. 42 x 16 x 40 (W x H x D, mm)

Weight

approx. 10 g

Ambient temperature

Operating 0…+50°C, storage -30…+70°C, 
avoid condensation

Inputs

2 x  video cameras via Cinch connectors, 1 Vss/75 ohm, 
video standard CCIR/PAL

Содержание 60133

Страница 1: ...Elsner Elektronik GmbH Control and Automation Engineering Sohlengrund 16 D 75395 Ostelsheim Phone 49 0 70 33 30 945 0 info elsner elektronik de Germany Fax 49 0 70 33 30 945 20 www elsner elektronik de Camera Interface for WS1 Color and WS1000 Style from software version 1 492 ...

Страница 2: ...er The software version is displayed with each start of the con trol system new start in menu System WS1 settings Service Reset The product conforms with the provisions of EU directives 2 Installation and Commissioning 2 1 Installation notes Installation testing operational start up and troubleshooting should only be performed by an electrician DANGER Risk to life from live voltage mains voltage T...

Страница 3: ... for possible mechanical damage If it has been damaged in transport inform the supplier immediately The device may only be used as a fixed site installation that means only when assem bled and after conclusion of all installation and operational start up tasks and only in the surroundings designated for it Elsner Elektronik is not liable for any changes in norms and standards which may occur after...

Страница 4: ...d connection The Camera Interface is screwed into the screen board of the control unit First re move the top nut of the fastening screw Put the interface on the 2 blocks with the 12 pins and press till firm 1 Camera input 1 and 2 2 Fastening screw 3 Pins connector plugs for the camera interface 1 2 Fig 2 3 Fig 3 Screw the interface tight as seen in the de tail view left ...

Страница 5: ... 711 12 If you order the cameras with Elsner Elektronik the right hinged ferrites are included Two ferrites must be fixed per one camera cable if possible directly behind the plug used for connecting the camera on the control Connect the cameras to the Cinch sockets of the Camera Interface No 1 and 2 The interface will be automatically recognised when the control unit is started and the correspond...

Отзывы: