– SAFETY INSTRUCTIONS 

 

This  section  includes  important  information  about  Safety.  Please,  read  it  carefully  before  installing  and 
operating the UPS.  
 

 

When opening the box, if UPS is damaged or dented don’t connect it to electrical network. Please call 
your reseller for product’s replacement 

 

Check the electrical rating written on the label on the rear of UPS, for being sure that input voltage rating 
is correctly set and in compliance with local Mains rating.  

 

UPS must be connected to an accessible and near plug. 

 

 

UPS is designed for supplying equipment such as computer, monitor, cash register, telephone system or 
similar. To supply any equipment different than above mentioned, please refer to your reseller or to call 
Naicon Service assistance for information 

 

Before cleaning the UPS, disconnect it from the Mains. To clean external surface, please use only a dry 
cloth. 

Don’t use any liquid cleanser, spray or chemical solvent, which may damage the electrical circuits 

of the device.  

 

This  UPS  operates  at  dangerous  volta

ges. Don’t  open the device. The UPS doesn’t include circuits or 

components accessible or  repairable by the user. ONLY authorized personnel may access to the unit. 

 

 

Connection  to  a  plug  without  Ground  connection  may  cause  electrical  shock,  and  is  not  in  compliance 
with Law regulation. 

 

 

Don’t connect UPS input to its own output. 

 

 

Don’t connect a multiple plug system or an overvoltage suppression system to the UPS.

 

 

In case of emergency, immediately push ON/OFF switch, disconnect the power cable from the wall plug 
to correctly shutdown the UPS.  

 

 

Don’t  cover  device’s  air  inlet,    avoid  direct  exposure  to  direct  sunlight  or  install  it  close  to  heating 
sources, in order to avoid any overheating of the unit. 

 

 

This  equipment  is  intended  to  be  used  in  interior.  Avoid  installing  the  UPS  in  locations  where  water  or 
excessive moisture are present.

 

 

Do not allow liquids or foreign bodies to penetrate the UPS. Do not place any drinks or any other liquid 
container on top or near the unit.

 

 

Battery maintenance must be carried out by experienced personnel.

 

 

Replace the batteries with the same type. 

 

The  voltage  of  internal  battery  is  set  at  12/24Vcc,  battery  is  sealed  and  contains  acid.  Do  not  open  or 
damage the battery. Released electrolyte is harmful to the skin and to the eyes. It can be toxic, too.

 

 

 Handling batteries may result in electric shock and short circuit. Observe the following precautions when 
working with batteries:

 

1) 

Don’t wear metallic objects 

2) Use tools with isolated handles 
3) Wear gloves and boots with rubber sole 
4) Do not place tools or metal objects on the batteries 
5) Disconnect the UPS before battery replacement. 

 

Do not throw the batteries in the fire as they may explode.

 

 

This UPS does not have to work either reversed or lying down. 

 

Batteries are already connected. 

 

Make sure that the sum of the leakage currents of the UPS and the loads connected to it does not 
exceed 3.5 mA before connecting the equipment. 

 

Be careful when disconnecting the equipment, there may be still residual voltages on the output sockets 
due to the battery voltage. Battery cables must be disconnected if you need to access the UPS. 

 

UPS is equipped with sealed lead-acid batteries. They are harmful if throw in the environment, so they 
must be disposed of in compliance with the relevant Community directives. To dispose of the UPS, you 
must contact the appropriate authorized sites in  your area, due to the electronic components and the 
plastic material of which the unit is made up. 

 

WARNING 

IN COMPLIANCE WITH THIS INSTRUCTIONS, ANY NON AUTHORIZED ASSISTANCE TO THE UPS 

LEAD TO CANCELLATION OF THE WARRANTY, 

 

Содержание NEMO 2.0 120

Страница 1: ...NEMO2 0 65 80 120 160 200 300 400 LINE INTERACTIVE Rev 02 27 Gennaio 2017 1 Nemo2 0 65 80 120 160 200 300 400 Single phase Line Interactive series Uninterruptible Power Supplies USER MANUAL...

Страница 2: ...s in order to avoid any overheating of the unit This equipment is intended to be used in interior Avoid installing the UPS in locations where water or excessive moisture are present Do not allow liqui...

Страница 3: ...h cold start function which means that even if the power supply is unplugged the UPS can be activated simply by pushing the ON OFF switch and will operated supplied by the battery Autorestart Upon ret...

Страница 4: ...on located on the UPS front panel and wait for the test completion until the beep ends and the blue display lights up Your UPS is now working From now on your computer and its connected devices are pr...

Страница 5: ...300 400 LINE INTERACTIVE Rev 02 27 Gennaio 2017 5 5 LAYOUT AND DESCRIPTION UPS FRONT VIEW 1 2 Rear view Nemo2 0 65 80 Rear view Nemo2 0 120 3 4 5 6 3 5 4 6 Rear view Nemo2 0 160 Rear view Nemo2 0 200...

Страница 6: ...r to the power outlet A fuse in the housing protects against overload 4 Output outlets Connect your loads to these outlets to be protected by the UPS 5 USB Communication ports For remote communication...

Страница 7: ...nnected to the power supply and is switched on via the front panel button After the end of the beep the LCD will turn on and the icon 3 will appear to indicate the operation of the power supply The UP...

Страница 8: ...display shows the icon 9 as in the figure moreover you will hear a continuous beep To reset the beep turn off the UPS with the On Off button on the front panel 8 TROUBLESHOOTING STATUS CAUSE SOLUTION...

Страница 9: ...600W 800W 1000W 1500W 2000W Switching time 2 6 mS tpc IEC outlet 2 2 4 2 2 2 2 Schuko outlet 2 2 2 2 NOISE FILTERING Modem T port 10BaseT 100baseT RJ11 RJ45 network compatible BATTERY Typ Autonomy tim...

Страница 10: ...cluded by the warranty Periodic maintenance and repair or replacement of parts subject to normal wear and tear Any modification or modification to the product without prior written permission from ELS...