background image

 

 

 

ELSETA

 

IOMOD 8AI

 

User manual

 

 

 
 

 

 

 

 

 

 

 

Elseta 
08/09/2021 
V1.3 

 

 

Содержание IOMOD 8AI

Страница 1: ...ELSETA IOMOD 8AI User manual Elseta 08 09 2021 V1 3...

Страница 2: ...nufacturer L Zamenhofo str 3 LT Vilnius Lithuania We claim that The device IOMod 8AI Conforms to the following standards EMC Radiation EN 55022 Class A 1 emitted radiation 30 1000MHz Second radiation...

Страница 3: ...ce may only be performed by a qualified professional authorized to perform commissioning grounding and labeling devices systems and circuits The person must be aware of occupational safety in the work...

Страница 4: ...bus register table 7 Read Input Status 7 Read Input Registers 7 c IEC 60870 5 103 operational information 7 4 Technical information 8 5 Mounting and installation guide 9 a IOMod 8AI RS485 interface 9...

Страница 5: ...rotocol used by a device can be changed by uploading corresponding firmware Default communication settings 9600 baud s baud rate 8N1 port configuration Slave address 1 a Common configuration informati...

Страница 6: ...defines limits from 0 to 100 that value should be between after recalculation Such a recalculation can be used in applications that require measurements in relative units such as percentage A device...

Страница 7: ...gister c IEC 60870 5 103 operational information IOMod with IEC 60870 5 103 firmware uses a standard communication scheme Initiation control messages and queries are initiated by a master controlling...

Страница 8: ...0 C and 20 80 RH 6 Configuration USB 7 Firmware upgrade USB mass storage device Electrical specifications 8 Inputs 16 bit resolution Channel Independent Programmable Input Ranges Voltage input Bipolar...

Страница 9: ...disabled over USB configuration It is recommended to use termination at each end of the RS485 cable See typical connection diagram in Fig 5 1 Fig 5 1 Typical IOMod connection diagram IOMod 8AI has 1...

Страница 10: ...is shown in Fig 5 2 See Configuration over USB chapter for instructions for analog input configuration Fig 5 2 Voltage input connection diagram for IOMod device All analog inputs can be configured as...

Страница 11: ...8AI 08 09 2021 V1 3 ELSETA Mounting and installation guide 11 5 3 See Configuration over USB chapter for instructions for analog input configuration Fig 5 3 Current input connection diagram for IOMod...

Страница 12: ...lled error as in Fig 6 1 Fig 6 1 Unsuccessful device software installation error A user then should manually install drivers by selecting a downloaded driver folder Go to Control Panel Device Manager...

Страница 13: ...ws to install VCOM will be provided To open up CLI simply connect to specific V COM port with terminal software advised to use PuTTY terminal software If other software is being used a user might need...

Страница 14: ...y on a keyboard to show the main menu again Modbus Main menu Name Function Values Default Values 1 Slave Address Setting Modbus Slave address 1 247 1 2 Communication settings 1 Baud rate 2 Data Stop a...

Страница 15: ...cancel 9 Diagnostics Raw input values 0 Exit Exit and disconnect Configuring an individual channel is a job requiring the most effort therefore an additional table is provided to make a configuration...

Страница 16: ...g factory predefined calibration coefficients However changing temperature and humidity conditions can affect the accuracy of measurements To get the best accuracy use the device at room temperature a...

Страница 17: ...can several values differing by the same value interval to get the best results Pressing ESC finishes calibration and saves coefficients to non volatile memory d Protocol simulation over USB After ent...

Страница 18: ...e existing file firmware bin and simply upload new firmware file by dragging and dropping as in Fig 6 11 Fig 6 11 Mass storage device for firmware upload Reconnect device and check the firmware versio...

Страница 19: ...odbus 9600 baud s baud rate 8 data no parity 1 stop bit When opening The Vinci software choose Modbus serial Master mode In the Settings tab choose station number default 1 configure tags as described...

Страница 20: ...TA Testing With THE VINCI software 20 opening The Vinci software choose IEC 60870 5 103 serial Master mode In Settings tab choose station number default 1 and ASDU default 1 press Start and go to Stat...

Страница 21: ...mation of the equipment manufacturer 21 8 Information of the equipment manufacturer Office address L Zamenhofo st 3 LT 06332 Vilnius Lithuania Tel 370 5 2032302 Email support elseta com In the web www...

Страница 22: ...version V1 1 2017 05 30 J S Technical information Mounting and installation guide V1 2 2018 12 17 A J Added more explanation on how to configure the device and its inputs Added calibration information...