ELSA AirLancer ISA-2 Скачать руководство пользователя страница 20

ELSA AirLancer

17

English

c)

if the damage occurred due to incorrect handling, especially to non-observance of the system
description and the operating instructions,

d)

if the device was opened, repaired or modified by persons not authorized by ELSA,

e)

if the device shows any kind of mechanical damage,

f)

if in the case of an ELSA Monitor, damage to the cathode ray tube (CRT) has been caused especially
by mechanical load (e.g. from shock to the pitch mask assembly or damage to the glass tube), by
strong magnetic fields near the CRT (colored dots on the screen), or through the permanent display
of an unchanging image (phosphor burnt),

g)

if, and in as far as, the luminance of the TFT panel backlighting gradually decreases with time, or

h)

if the warranty claim has not been reported in accordance with 3a) or 3b).

5

Operating mistakes

If it becomes apparent that the reported malfunction of the device has been caused by unsuitable
software, hardware, installation or operation, ELSA reserves the right to charge the purchaser for the
resulting testing costs.

6

Additional regulations

a)

The above conditions define the complete scope of ELSA’s legal liability.  

b)

The warranty gives no entitlement to additional claims, such as any refund in full or in part.
Compensation claims, regardless of the legal basis, are excluded.  This does not apply if e.g. injury
to persons or damage to private property are specifically covered by the product liability law, or in
cases of intentional act or culpable negligence.

c)

Claims for compensation of lost profits, indirect or consequential detriments, are excluded.

d)

ELSA is not liable for lost data or retrieval of lost data in cases of slight and ordinary negligence.

e)

In the case that the intentional or culpable negligence of ELSA employees has caused a loss of data,
ELSA will be liable for those costs typical to the recovery of data where periodic security data back-
ups have been made.

f)

The warranty is valid only for the first purchaser and is not transferable.

g)

The court of jurisdiction is located in Aachen, Germany in the case that the purchaser is a merchant.
If the purchaser does not have a court of jurisdiction in the Federal Republic of Germany or if he
moves his domicile out of Germany after conclusion of the contract, ELSA’s court of jurisdiction
applies.  This is also applicable if the purchaser's domicile is not known at the time of institution of
proceedings.

h)

The law of the Federal Republic of Germany is applicable.  The UN commercial law does not apply
to dealings between ELSA and the purchaser.

Содержание AirLancer ISA-2

Страница 1: ...Manual M ELSA AirLancer TM MC 2 M ELSA AirLancer TM ISA 2...

Страница 2: ...subject to written authorization from ELSA We reserve the right to make any alterations that arise as the result of technical development Trademarks Windows Windows NT and Microsoft are registered tr...

Страница 3: ...ocumentation comprises K Installation Guide Hardware installation and configuration examples K CD containing electronic documentation All product manuals basic technical information e g wireless netwo...

Страница 4: ...bile stations into an internal company e mail system Radio transmission IEEE 802 11 Wireless network cards from ELSA operate under IEEE Standard 802 11 This standard is a supplement to the current IEE...

Страница 5: ...r This application is generally referred to as a peer to peer network however in the jargon of wireless networks this type of networking is referred to as an ad hoc network Connection to wired LAN All...

Страница 6: ...e PCMCIA slot is active and that the card driver was successfully loaded K The yellow LED indicates that the wireless network card is logged on to a base station K The green LED shows the activity on...

Страница 7: ...ELSA AirLancer 4 English...

Страница 8: ...network the TCP IP protocol must be installed In addition the NetBEUI network protocol is required for Windows networks in the ad hoc mode Install ELSA AirLancer ISA 2 a Safety First Disconnect the po...

Страница 9: ...free PCMCIA slot of a notebook computer or into the PCMCIA adapter ELSA AirLancer ISA 2 Note the marks to ensure that the card is in the correct position The card will be recognized automatically and...

Страница 10: ...ncer ISA 2 has not been properly loaded you will find the entry Empty Socket 0 here Install driver for ELSA AirLancer MC 2 When installing under Windows NT 4 0 check whether the required system resour...

Страница 11: ...on Standard if you wish to set up a direct connection to another computer with the wireless network card peer to peer e Finish the installation and restart your computer After installing the drivers c...

Страница 12: ...the computers together A small Windows network in which every computer can have wireless access to the released files folders and printers on the other computers can be set up very quickly For exampl...

Страница 13: ...ce caused by superimposition Please note that not all channels in all countries are available for private use see table with radio channels in the appendix K LLC Type remains at IEEE 802 11 for all co...

Страница 14: ...he workstations in the Microsoft network to log on with names and passwords K Capab File and printer sharing permits drives and printers to be shared with other users in the Windows network K Name and...

Страница 15: ...he network in the Windows Explorer Network Neighborhood including the user s own computer The released folders and files are as easily accessible in Explorer as the hard disks and drives in the user s...

Страница 16: ...e station Open the Network Neighborhood with Start E Settings E Control Panel E Network Highlight the entry ELSA AirLancer MC 2 and choose the properties Open the register card Advanced and check the...

Страница 17: ...umentation on the CD Access to the LAN After setting up the wireless network cards all functions and services available on the desktop PCs in the wired network will be available for the marketing empl...

Страница 18: ...enclosed structures typical range Antenna 2dBi dipole antenna Bit error rate Better than 10 5 Standard IEEE 802 11 DSSS Direct Sequence Spread Spectrum Operating sys tems Windows 95 Windows 98 Window...

Страница 19: ...warranty period for ELSA products is six years Excepted from this warranty period are ELSA color monitors and ELSA videoconferencing systems with a warranty period of 3 years This period begins at the...

Страница 20: ...titlement to additional claims such as any refund in full or in part Compensation claims regardless of the legal basis are excluded This does not apply if e g injury to persons or damage to private pr...

Страница 21: ...WKLV SURGXFW PHHWV DOO HVVHQWLDO SURWHFWLRQ UHTXLUHPHQWV UHODWLQJ WR WKH 1LHGHUVSDQQXQJV 5LFKWOLQLH RZ 9ROWDJH LUHFWLYH 09 5LFKWOLQLH 0 LUHFWLYH XU HXUWHLOXQJ GHU RQIRUPLW W ZXUGHQ IROJHQGH 1RUPHQ KH...

Страница 22: ...tlinie 73 23 EWG Low Voltage Directive 73 23 EEC EMV Richtlinie 89 336 EWG EMC Directive 89 336 EEC Zur Beurteilung der Konformit t wurden folgende Normen herangezogen The assessment of this product h...

Страница 23: ...ELSA AirLancer 20 English...

Отзывы: