Process end
Process end is signalized by flashing of the displayed data, display's backlight blinking and periodic sound signal.
After 30 seconds a sound signal is replaced by “silent knocking”. Display shows the last values measured during the
process.
A new process on the same accu pack can be started after reconnecting of the accu pack!
Main menu
(
battery is disconnected)
Main menu consist of 10 windows.
•
M 1-8 processes memory, formatting/regeneration and battery test
Memory of the processes M1-8
Memory number – a digit in the right down corner on display.
There are 8 memories. Each can save:
Process parameters
Main parameter is charging/discharging current. at the complex processes (discharging/charging,
charging/discharging) there is a possibility to set up different value of charging/discharging current.
Work mode
discharging –
Disch
., charging –
Charge
,
discharging /charging –
Dis/Ch.
, charging/discharging –
Ch/Dis.
Cell Type
Ni-Cd, Ni-MH, Pb-bat, RAM, Li-Ion, Li-Pol, Li-Ta, Li-Ph
Info window
(
battery is disconnected)
To open information window press the
M
key.
V b = 1 2 , 5 V
T c = 2 3 , 7
M e m
2 , 1 3 1 A h
Vb=12,5V
- supply
voltage
Tc=23,7
-
battery pack temperature (--,- - sensor not connected)
Mem
-
saved data from 8 previous processes
2,131Ah
-
energy measure from last process
To read data from 8 previous press the
E
key.
M 8 1 6
N i - C d
M e n u - 2 , 1 3 1 A h
M8
-
save no. 8
16
- amount
of
cells
Ni-Cd
-
cell type
Menu
-
return to main menu (E)
-2,131Ah
-
energy, mark (-) means discharge
Info.
Keys
Function
+ or –
change program
Battery
disconnected
M info
window
M
return to main menu
Info window
E
saved data from 8 previous processes
+ or –
change save no.
E
return to main menu
Saved data
M
return to info window