21
the cable length must less 5 meters between HE02R receiver and wall socket.
The wiring diagram as below:
├
───────────── Cat.6 MAX 100M ──────────────
┤
┌───┐ ┌─────┐ ┌─────┐ ┌────┐
│
EL-MX-B004
│─────│
Wall Jack
│──────────────│
Wall Jack
│─────│
HE02R
│
└───┘ MAX 5M └─────┘ └─────┘ MAX 5M └────┘
9.0 HDBaseT RJ45 Pin Define:
Video Link ( TIA/EIA-568-B )
1. Orange-white
DATA0 +
2. Orange
DATA0 -
3. Green-white
DATA1 +
4. Blue
DATA2 +
5. Blue-white
DATA2 -
6. Green
DATA1 -
7. Brown-white
DATA3 +
8. Brown
DATA3 -
Caution:
1.
First time to use EL-MX-B004 remote control or change new batteries must set up
IR ID.
2.
The wiring must away from any equipment with electromagnetic wave, i.e.:
microwave, mobile phone, radio equipment, high voltage,
Fluorescent light fixtures,
power lines, etc.
3.
HDBaseT are not regular network device, do not connect with any networking
equipments to avoid damage.
4.
IP Address, Subnet Mask, Gateway, DHCP Client, Media Type, MAC Filter setting
made by EL-MX-B004 ETHERNET MENU or by RS232 or by software application. See
10.0
5.
HDBaseT IR operation: Do not make IR emitter and receiver cable too close, to
avoid interference and caused wrong operation.
6.
HDBaseT RS232 under distribution mode: it not
able to control two devices
simultaneously.