ELPRO ECOLOG-PRO Series Скачать руководство пользователя страница 2

Document: EP6001Eb

2 - EN

ELPRO-BUCHS AG
Warranty conditions and liability disclaimer

Liability

-

ELPRO-BUCHS AG does not accept any liability for direct, indirect, special, incidentally occurring, randomly occurring or subsequent damage 
or losses including lost profit or data resulting from the use of their data loggers, sensors, accessories, software products or information from 
the documentation.

-

ELPRO-BUCHS AG does not bear any responsibility for the installation of the software products. 

-

ELPRO-BUCHS AG does not provide any guarantees, either explicit or implicit, regarding the usability or suitability of their products for a 
specific purpose. 

-

In the interest of our customers we reserve the right to make changes and discontinue the product on the basis of technical advancement. For 
this reason the functionality, diagrams, descriptions and scope of supply can be modified without prior notification!

-

As individual countries or states do not permit the concept of an implicit warranty or a liability disclaimer for incidental or subsequent damage, 
the restrictions and disclaimers may not apply to all customers. If one of the provisions of this warranty is declared by a competent court to be 
invalid or not enforceable, this does not affect the validity or enforceability of the remaining provisions.

-

ELPRO-BUCHS AG does not accept any liability for transport damage or any consequential damage arising therefrom.

-

In general the statutory regulations of Switzerland apply. The place of jurisdiction is the district court of Werdenberg-Sarganserland.

Guarantee

-

The guarantee obligations of ELPRO-BUCHS AG are limited to reworking, reimbursement of the purchasing price, repair free of charge or the 
replacement of a faulty product that is returned within the guarantee period to ELPRO-BUCHS AG or an approved reseller of ELPRO-BUCHS 
AG.

-

There is no obligation to provide on-site customer support by an employee of ELPRO-BUCHS AG.

-

The guarantee is only applicable to the original purchaser or end user and customer of an approved reseller of ELPRO-BUCHS AG.

-

Resellers approved by ELPRO-BUCHS AG are not authorized to enter into any extended or different guarantee obligations in the name of 
ELPRO-BUCHS AG.

-

ELPRO-BUCHS AG provides a guarantee of 24 months on the following new products:
-

Data logger

-

Brackets

-

Accessories excluding sensors and third-party products

-

This guarantee is valid for material faults or production faults.

-

ELPRO-BUCHS AG provides a guarantee of 6 months for the following products and services:
-

All servicing and repair work

-

Pt100 sensors

-

Humidity sensors

-

ELPRO-BUCHS AG provides a 90 day guarantee that the medium on which the software product is supplied is free from material and 
processing faults under normal conditions. All main items of the software product comply with the operating instructions and the information in 
the help file. 

-

The guarantee does not apply to consumables, disposable batteries or any other product that ELPRO-BUCHS AG deems to be:
-

misused

-

modified

-

replaced by an incorrect product

-

damaged as the result of an accident or operational or handling conditions that do not comply with the specifications.

-

Wear, cable breakage, and corrosion are not covered by the guarantee.

-

For third-party products ELPRO-BUCHS AG provides the maximum guarantee period of the manufacturer.

-

ELPRO-BUCHS AG only provides a guarantee and customer support for discontinued products for a limited period.

-

Repair work covered by the guarantee is solely carried out at the works (ELPRO-BUCHS AG) or by an agent approved by the works. 

-

ELPRO-BUCHS AG does not offer any guarantee for the standard or SCS calibration of data loggers and sensors. The stated data correspond 
to the situation during the calibration process.

Software

-

The software products of ELPRO-BUCHS AG are subject to internal quality requirements and are validated regularly at the works. In the event 
of program errors, circumvention of the error is regarded as constituting its elimination.

-

Software manuals do not contain either instructions on basic operation of a computer or the basic functions of the Windows® operating system. 
For information on the operation of the computer or the operating system please refer to the applicable computer manuals.

Data loggers, sensors and 
accessories

-

ELPRO-BUCHS AG applies the highest quality standards during production of data loggers and their accessories, and implements a certified 
quality management system in compliance with ISO 9001.

-

For information on operation of data loggers and their accessories, please refer to the respective product documentation supplied by ELPRO-
BUCHS AG.

-

During the installation of data loggers, sensors, and accessories, compliance with the locally valid installation regulations is mandatory.

-

When used in potentially explosive atmospheres, the zone category and the application and safety instructions of ELPRO-BUCHS AG must be 
complied with.

-

In the event of a guarantee claim, customers receive a repair cost estimate from ELPRO-BUCHS AG to obtain the corresponding consent 
before starting work.

-

The customer will bear the transport costs incurred for any repairs carried out by ELPRO-BUCHS AG. The DAP (value added tax) is borne by 
ELPRO-BUCHS AG.

-

ELPRO-BUCHS AG reserves the right to invoice the customer for costs incurred for repair/part replacement..

-

After repair work the product is returned to the purchaser, who will be charged with the return shipping costs (FOB shipping point).

Trademarks

All stated company and product names and their trademarks are the protected property of the respective owner.

Содержание ECOLOG-PRO Series

Страница 1: ...ECOLOG PRO Modules Operation Manual ...

Страница 2: ...s free from material and processing faults under normal conditions All main items of the software product comply with the operating instructions and the information in the help file The guarantee does not apply to consumables disposable batteries or any other product that ELPRO BUCHS AG deems to be misused modified replaced by an incorrect product damaged as the result of an accident or operationa...

Страница 3: ...cuit Diagram 11 3 3 Sensor Status 11 4 ECOLOG PRO 4MA 4 20 mA Measurement Module 12 4 1 Circuit Diagram 13 4 2 Sensor Status 13 5 Module with Contact Inputs ECOLOG PRO 4DI 14 5 1 Contact Statuses 15 5 2 Circuit Diagram 15 6 Module with Contact Outputs ECOLOG PRO 4DO 16 6 1 Contact Statuses 17 6 2 Alarm Indicator Power Supply and Ground 18 6 3 Local Alarm 18 6 4 Alarm Forwarding 18 7 1250 mA Power ...

Страница 4: ... elproMONITOR SV6031D In the interests of our customers we reserve the right to make any changes result ing from technical advances For this reason diagrams descriptions and the scope of delivery are subject to change without notice This manual is valid as from Version 2017 CHANGES OR MODIFICATIONS MADE TO THIS EQUIPMENT MAY RENDER NULL AND VOID THE ETSI FCC AUTHORIZATION TO OPERATE THIS EQUIPMENT...

Страница 5: ...anufacturer guarantees that this product complies with the relevant guidelines EN 61000 6 2 2001 and EN 61000 6 4 2001 FCC ID Z45 E11645398 IC 9954A E11645398 This product must be disposed of in accordance with WEEE Waste Electrical and Electronic Equipment 2002 96 EC ...

Страница 6: ...e LBR ECOLOG PRO 4MA is the measurement module for analog signals The module has 4 inputs for standard 4 20 mA signals The monitored transmitters can be powered by the module or by an external power supply For operation it is connected to a LAN bridge LBR ECOLOG PRO 4DI is the module with 4 contact inputs digital inputs for the ECOLOG PRO system The monitored contacts are powered by the module For...

Страница 7: ... power supply unit Use of an incorrect power supply unit may cause damage to the device Always replace defective or damaged power supply units Cleaning To clean the modules use a slightly moist cloth Never use thinner gasoline alcohol or any other cleaning agents since they may damage the housing Environmental Conditions Make sure the modules are at room temperature before initial startup No guara...

Страница 8: ...atus green link ok red link inactive Power supply 24 VDC 10 to 20 By external power supply unit Maximum connection cable length 30 m Functional ground is optional Maximum number of measure ment modules The maximum number of measurement modules is defined by the specifica tions of the power supply unit or the limits of the ECOLOG PRO LBR Maximum 2500 mA system bus 32 measurement modules Power suppl...

Страница 9: ...G PRO LBR COMMUNICATION MODULE 9 EN 2 1 Power Supply Unit Circuit Diagram Power supply unit Chapter 7 1250 mA Power Supply Unit Accessories Functional ground Connect the functional ground when shielded sensor cables are used ...

Страница 10: ...Sensor error and cable fault are not considered Measurement resolution 0 1 C Cable fault up to 30 m 4x0 25 mm2 without shield 30 m to 50 m 4x0 25 mm2 with shield 50 m to 80 m 4x0 34 mm2 with shield 0 06 C 0 1 C 0 2 C Logging interval 1 minute to 60 minutes Each channel is capable of logging at a separate interval Date and time Internal system clock The clock is synchronized permanently to elpro MO...

Страница 11: ...is stored in the internal non volatile module memory Content of package Measurement module Connecting hook see module rear Information leaflet Validation certificate The plugs for sensor connection are not included in the scope of supply Cable A Cable B Cable C Part No 800508 M12 plug to Pt100 sensor Terminal Cable A Cable B Cable C 1 red white white 2 red brown brown 3 white black green 4 white b...

Страница 12: ...4 mA Transmitter power supply 24 VDC 20 Pmax 3 W Load 50 to 100 ohms Measurement accuracy of module 0 04 mA up to 30 m 4x0 25 mm2 without shield Measurement resolution 0 01 mA Connection cable length max 200m Logging interval 1 minute to 60 minutes Each channel is capable of logging at a separate interval Date and time Internal system clock The clock is synchronized permanently to elpro MONITOR sy...

Страница 13: ...h external power supply 4 2 Sensor Status Calibration data Data is stored in the internal non volatile module memory Content of package Measurement module Connecting hook see module rear Information leaflet Validation certificate The plugs for sensor connection are not included in the scope of supply Terminal 1 Ground 2 3 Signal 4 5 Power supply Status dark No channel configured green All configur...

Страница 14: ...ent for all 4 sensors is 120 mA Statuses Open Closed Connection cable length max 200m Logging interval 1 minute to 60 minutes Each channel is capable of logging at a separate interval Pulse length 200 ms Minimum time interval to detect status change Date and time Internal system clock The clock is synchronized permanently to elpro MONITOR system time Module power supply Via internal system bus Dat...

Страница 15: ...in each measurement sampling period A Number of edge changes B Total duty cycle as percentage of measurement sampling period C Present contact status Example 5 2 Circuit Diagram CH1 Example Switch or 2 wire sensor powered by the module CH3 Example 3 wire sensor powered by the module Door monitoring Time interval of open doors Number of door openings per measurement sampling period Terminal 1 Groun...

Страница 16: ...DCV see 6 2 Alarm Indicator Power Supply and Ground External power supply unit for alarm indicators 12 to 24 VDC Max switching current per contact 100 mA Connection cable length max 200 m Threshold values and time response The contacts are parameterized threshold values and alarm delay times by the elproMONITOR Date and time for alarm delay times Internal system clock The clock is synchronized per...

Страница 17: ...THE POWER SUPPLY UNIT MUST BE CONNECTED TO ENABLE ALARM SIGNALS Pin 1 GND Com contact Pin 2 NO Normally Open contact Pin 3 GND Com contact Pin 4 NO Normally Open contact Pin 5 Contact for external power supply Internal connected to all 4 module channels The NC and NO contacts are open in these operating states No alarm signals are generated No alarm is present in this operating state An alarm is p...

Страница 18: ...when the contact closes 6 4 Alarm Forwarding Example Contact CH1 monitored by central plant system An alarm is triggered when the contact opens This circuit layout allows wire break monitor ing Alarm indicator grounds are electrically isolated from the system bus ground Terminal 1 Ground 2 3 Ground 4 Closes in event of an alarm NO 5 Alarm indicator power supply Only one power supply unit is possib...

Страница 19: ...e design plug in power supply units are delivered with replaceable country specific plugs for AC input Power supply unit see Accessories for Part No Input voltage 100 240 VAC 10 50 to 60 Hz Country versions Europe U K U S A Output voltage 24 VDC 5 Output current max 1250 mA Dimensions 90x55x34 Connection cable length 1830 mm Content of package Power supply unit with connection cable and plug for c...

Страница 20: ...y unit and the network To carry out the configuration the ECOLOG PRO LBR must be in the same logical network as the PC which is used for the configuration Start Module Configu rator as administrator Step 1 In the start window of the Module Configurator left click on the field LBR and open the win dow to select the search functions Search the ECOLOG PRO LBR using one of the 3 methods below Start wi...

Страница 21: ... IP address 3 Hostname Define the ECOLOG PRO LBR for configuration by entering the host name Standard Host name serial number Step 3 After a successful search the input fields are completed with the current settings of the selected module and enabled for processing Enter or adapt and assign the network parameters in this window ...

Страница 22: ... U S plug 802100 CTR_ECOLOG PRO Channel Plug to connect a sensor 802101 CTR_ECOLOG PRO LBR Plug to connect a power supply unit 800508 CTR_M12F_IDC M12 F cable coupling to connect sensor 800513 CTR_M12M_IDC M12 M cable coupling to connect sensor Author Date Version Description ANGUB March 8 2017EP6001D First release ANGUB 16 June 2017 EP6001Da Designation of power supply unit changed ANGUB 24 Aug 2...

Страница 23: ...EN 23 Document EP6001Eb ...

Страница 24: ...Operation Manual ECOLOG PRO EP6001Eb ELPRO BUCHS AG Langäulistrasse 45 9470 Buchs SCHWEIZ E Mail swiss elpro com ...

Отзывы: