805U Radio Modem Module
User Manual
Page
56
©
November 2004
S6
0-255
Link Check Timer
Units Seconds. 0 disables. How frequently
to send a “Link Check” message. Usually
set less than the timeout set by the AT\T
command. Default 0.
S7
1-255
Number of Connection
attempts
How many times to attempt a connection
after an ATD command. Default 5.
S8
0-255
Test Timer
Units Seconds – How long to run tests
(AT&Tx). Default 0 (no time-out).
S9
0-255
Module Receive Level
Units (-)dBm - RSSI indication of last
received message
S10
0-255
DTR Loss Detection Time
Units 10 milliseconds
S11
0-255
Not used
S12
read-
only
Command Mode Diagnostic
Reason module last returned to command
mode, i.e. connection lost.
S12 = 0
Reset (ATZ or Power Up).
S12 = 1
Escape sequence (“+++”)
S12 = 2
DTR lowered.
S12 = 3
No ACK from remote module after connected.
S12 = 4
Activity timer timed out.
S12 = 5
No response to dial request to remote module.
S12 = 6
“BUSY” response from remote module on dial request.
S12 = 7
Character received from host while attempting to connect
S12 = 8
Hang-up from remote module.
S13
0-3
Country code for radio (not
user configurable)
0 = US/Canada 1 = Australia
2 = New Zealand 3 = Europe
S14
0-255
Max Data Packet size
transmitted by radio
Max Packet size = 20 + (S14 x 2). Default
255 = 530 bytes
S15
0-7
Not Used
S16
0-255
Transmit Hold-off Time
In msec (default = 0)
S17
0-255
Receive Hold-off Time
In msec (default = 0)
S18
0-255
Input buffer delay
Radio will not transmit until the number of
characters in the input buffer = 2 x S18
value - see below
S19
0-255
Input buffer delay override
Override time in msec to override S18 delay
- see below.
S20
0-255
Default system address
S18 is calculated as
S18 = (MP – (SR * (10*MP/RB + TD)) / 2 (Rounded up)
SB is serial baud Rate, (in
bits
per second)
SR is serial data Rate, (in
bytes
per second – usually 1/10
th
of SB)