805U Radio Modem Module
User Manual
Page
44
©
November 2004
Module #2
Set the module to factory default settings:
AT&F
Set the system address to the same random number:
AT&S217
Set the unit address to 2
AT&U2
Set the operating mode to controlled mode
AT&M2&L3
Note that this module can be configured as any controlled mode, except for fast operation.
Exit and save the configuration
AT&W
ATO
Module #3
Set the module to factory default settings:
AT&F
Set the system address to the same random number:
AT&S217
Set the unit address to 3
AT&U3
Set the operating mode to controlled mode, auto-connect, slave
AT&M2&L3
Exit and save the configuration
AT&W
ATO
Module #100
Note that #100 is the master unit for a link between #100 and #101, It is also acting as
repeater in the #1 to #3 link. The system address for #100 and #101 must be the same as the
other modules so that #100 can act as a repeater.
Set the module to factory default settings:
AT&F
Set the system address to the same random number:
AT&S217
Set the unit address to 100
AT&U100
Set the autodial address to 101
AT&Z0=101
Set the operating mode to controlled mode, auto-connect, master
AT&M2&L2
Exit and save the configuration
AT&W
ATO
The configuration for #101 is not shown as it is not part of the active link.
4.7
Switch Configuration
Some configurations can be made using the four DIL switches mounted in the end-plate of
the module.
The DIL Switches are only read at power-up, and change the volatile configuration of the
module. The non-volatile configuration is not changed. DIL Switch settings allow the factory
configuration to be restored, testing functions, and some simple back-to back configurations.
If you want the module to start up in the same way each time, you will need to leave the
switches in the same setting. If you are using the switches to do temporary changes, then you
should change the switches back to the zero position after powering up.