805U-E Wireless Ethernet
User Manual
Man_805U-E Rev 1.5
Page 20
3.2
Default Configuration
The default factory configuration of the 805U-E is
•
Bridge/Client
•
IP address192.168.0.1XX, where XX is the last two digits of the serial number (the
default IP address is shown on the printed label on the back of the module)
•
netmask 255.255.255.0
•
Username is “user” and the default password is “user”
The 805U-E will temporarily load some factory-default settings if powered up with the
Factory Default switch (on the end-plate of the module) in SETUP position. In the position,
wireless operation is disabled. The previous configuration remains stored in memory and
will only change if a configuration parameter is modified and the change saved.
Do not forget to set the switch back to the RUN position and cycle power at the conclusion
of configuration for resumption of normal operation.