WARNINGS/PRECAUTIONS

WARNING!

Indicates possibility of physical harm to the 
user in case of non-compliance

CAUTION!

Indicates possibility of damage to the 
equipment in case of non-compliance

FOLLOW OPERATING   
INSTRUCTIONS  

 WARNINGS!

1.

  DO NOT OPEN TO REDUCE THE RISK OF 

FIRE OR ELECTRIC SHOCK. THERE ARE 
NO SERVICEABLE PARTS INSIDE – REFER 
TO QUALIFIED SERVICE PERSONNEL 

 

2.

  It is recommended that you return the interface to a 

qualified dealer for any service or repair, incorrect as

-

sembly may result in electric shock or fire.

3.

  To reduce risk of electric shock, unplug the DC input 

(battery) before attempting any maintenance or cleaning.

4.

  To reduce risk of damage to electric plug and cord, pull 

by plug rather than cord when disconnecting anything 
from the unit.

5.

  An extension cord should not be used unless absolutely 

necessary. If an extension cord is used, make sure that 
is has a 3-prong, male plug (NEMA1-15P and 3-Prong), 
female receptacle (NEMA1-15R). The size of the current 
carrying conductors should be such that they are able 
to carry at least 2.5A for the length of the extension. 

6.

  Place the unit in an area that will allow air to flow freely 

around the unit. DO NOT block or obstruct vent open

-

ings or install the unit in an enclosed compartment. 

7.

  Keep the unit away from moisture and water

8.

  Never operate two or more units in parallel.

9.

  Not approved for use in the patient environment. 

10.

  Never attempt to charge any battery that is damaged 

in any way. 

11.  WARNING:

 To avoid risk of electric shock, this equip-

ment must only be connected to a supply mains with 
protective earth.

12.  WARNING:

 No modification of this equipment is 

allowed.

13.

  Do not manually depress and/or override the cabinet 

door’s interlock switch. 

14.  WARNING: 

This device is designed to conform to 

Electromagnetic Compatibility (EMC) standard IEC 
60601-1-2 and will operate accurately in conjunction  

 

with other medical equipment which also meets this
requirement. To avoid interference problems affecting
the device, do not use the device in the presence  
of equipment which does not conform to these 
specifications. 

FCC NOTICE

This equipment has been tested and found to comply with 
the limits for a Class A digital device pursuant to Part 15 
of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference when 
the equipment is operated in a commercial environment. 
This equipment generates, uses, and can radiate radio fre -
quency and, if not installed and used in accordance with 
the instruction manual, may cause harmful interference 
to radio communications. Operation of this equipment in 
a residential area is likely to cause harmful interference 
in which case the user will be required to correct the 
interference at their own expense. This equipment has 
been approved by one or more agencies. All changes and/
or modifications not expressly approved by Elora
International. could void the users’ warranty and authority
to operate this equipment. There are no serviceable parts in 
this equipment.

Содержание ELORA 3

Страница 1: ...ELORA 3 STATION CHARGING CABINET Owner s Manual 7595 0445 Revision A ...

Страница 2: ...RA 3 STATION CHARGING CABINET Owner s Manual 2 IMPORTANT READ AND UNDERSTAND THIS MANUAL BEFORE OPERATION INTRODUCTION KEY FEATURES AND BENEFITS SPECIFICATIONS WARNINGS PRECAUTIONS ORDERING INFORMATION 3 4 4 6 13 14 CONTENTS ...

Страница 3: ...SONAL INJURY ELORA ACCEPTS NO RESPONSIBILITY FOR ANY INJURY OR DAMAGE ASSOCIATED WITH THE USE OF BATTERIES NOT MANUFACTURED OR BATTERIES SERVICED OTHER THAN BY ELORA SUCH USE WILL VOID ANY WARRANTY Special precautions and handling instructions are contained in this manual and should be strictly adhered to for safe and reliable operation Contact ELORA Customer Support Group at 1 888 77ELORA or cust...

Страница 4: ...LED indicates that the battery has been completely charged is ready for use and has the highest capacity run time This is the battery that should be removed first Only one battery will indicate green at a given time Once this battery has been removed the next fully charged battery if available will illuminate green indicating that it is ready for use and has the highest capacity run time This assu...

Страница 5: ...lt Elora Customer Support Group for information on disposal recycling of the Elora Charging Cabinet and its associated components and or accessories OPERATING ENVIRONMENT TEMPERATURE RANGE 0ºC to 30ºC 32ºF to 86ºF RELATIVE HUMIDITY 20 70 non condensing PRESSURE 985 hPa 1040hPa TRANSPORTATION STORAGE ENVIRONMENT TEMPERATURE RANGE 20ºC to 40ºC 4ºF to 104ºF RELATIVE HUMIDITY 20 70 non condensing PRES...

Страница 6: ...ent must be three conductor and be correctly wired to provide connection to earth ground Improperly wired extension cords are a dangerous electrical hazard The fact that the equipment operates satisfactorily does not imply that the power point is properly grounded and that the installation is completely safe If any doubt exists about the correct grounding of the power point consult a qualified ele...

Страница 7: ... ensure that over charge conditions are avoided FUL This determination is made when a fully charged DIGITAL battery is returned to a charger within specified parameters of time temperature and battery voltage The DIGITAL battery communicates its fully charged condition and the charger confirms the parameters and immediately indicates a fully charged condition without additional verification TEMPER...

Страница 8: ...the charger and the battery only Elora Series batteries should be used in this charging cabinet SHUTDOWN PROCEDURE If the unit were to require shut down the ON OFF switch to the unit is mounted on the front panel in the lower right corner The O indicates that the power is OFF This switch in the OFF position isolates the supply mains from the device The system may continue to run if batteries are m...

Страница 9: ...MUST BE LEVEL AND SPACED APPROPRIATELY BEFORE THE CABINETS ARE INSTALLED ITEMS SHOULD NOT BE PLACED ON THE TOP OF THE CABINETS USE CAUTION WHEN HANDLING SHEET METAL PARTS THE EDGES MAY BE SHARP CAUTION Make sure the wall meets the load capacity requirements for the cabinet being installed The wall the unit is to be mounted to shall be thick drywall or greater with studs spaced 16 on center apart f...

Страница 10: ...cabinet see figure 1 3 Remove these two screws do NOT discard 4 Push down on the mounting plate on the back of the cabinet This should allow it to be removed from the cabinet 5 Determine the vertical position at which the top of the cabinet is to be located This location should be aligned with a stud within the wall Failure to do so could result in the cabinet becoming dislodged from the wall and ...

Страница 11: ...1 8 wide This will allow for the cabinet to fit inside of the opening and for the mounting bezel to attach to the wall without any open spaces around the cabinet to be visible Use caution when removing sheetrock to ensure that no existing wiring or plumbing within the wall is disturbed 6 After creating the rough opening use the mounting bezel as a template and mark the locations for the bolts 7 Dr...

Страница 12: ...www elorapower com ELORA 3 STATION CHARGING CABINET Owner s Manual 12 LINE DRAWINGS SPECIFICATIONS ...

Страница 13: ...e Remove applicable knockout Assemble a UL listed conduit con nector in the opening A Removable Retaining Nut B Strain Relief Feed the flexible conduit through the strain relief allowing enough slack to easily attach wiring to the device Tighten strain relief screw against the flexible conduit Knockout ...

Страница 14: ...www elorapower com ELORA 3 STATION CHARGING CABINET Owner s Manual 14 SPECIFICATIONS Complete wiring as shown below ...

Страница 15: ...n the patient environment 10 Never attempt to charge any battery that is damaged in any way 11 WARNING To avoid risk of electric shock this equip ment must only be connected to a supply mains with protective earth 12 WARNING No modification of this equipment is allowed 13 Do not manually depress and or override the cabinet door s interlock switch 14 WARNING This device is designed to conform to El...

Страница 16: ...AMAGE RESULTING FROM ACCIDENTS DISASTER NEGLECT MISUSE IMPROPER INSTALLATION IMPROPER OR UNAUTHORIZED SERVICE OR MAINTENANCE UNAUTHORIZED REPLACEMENT PARTS OR ATTACHMENTS OR DYSFUNCTION OR MALFUNCTION OF OR CAUSED BY ANY OTHER PRODUCT OR DEVICE Misuse includes any use of the Product in other than its intended application including the use of this Product with any charging device or accessory not m...

Страница 17: ...er Support customersfirst elorapower com 1 888 77ELORA Call 1 888 77ELORA or email us at customersfirst elorapower com Visit our website at www elorapower com Copyright 2019 Elora International All rights reserved ...

Отзывы: