1.0 

Introduction 

RS-422  (V.11)  is  a  duplex  interface  for  two  devices´  communication.  The 
symmetric  signals  are  transmitted  via  the  twisted  pair  and they are immune to the 
interference. Maximum range is 1200m which can be increased using repeaters.  

 

1.1 

Use of the converter 

The  fibre  optic  cable  is  immune  to  electromagnetic  interference  and  atmospheric 
electricity  influences,  it  provides  maximum  DTE  protection  and  high 
communication  reliability.  The  distance  between  devices is not more than 2km so 
using multimode fibres is economically convenient in automation.   
 

2.0 

Operation principles 

The converter transfers Tx signal of the RS-422 interface to the transmitting optic 
fiber  and  copies  it  from  the  receiving  optic  fiber  to  Rx  of  the  RS-422  interface. 
Maximum  data  rate  limit  is  115.2  kbps.  LED  diodes  indicate  the  transmitted  and 
received signal. 
 

3.0 

Installation 

This part describes the ELO E174 converter installation principles. 
 

3.1 

Optic link connection 

ST  400  connectors  are  used  to  connect  the  fiber  optic  cable.  To  connect  two 
converters, the TRANSMIT connector of the local converter has to be connected to 
the  RECEIVE  connector  of  the  remote  converter  and  the  RECEIVE  of  the  local 
converter has to be connected to the TRANSMIT connector of the remote one. The 
cable has to be multimode 50/125 or 62.5/125μm and it should not be longer than 
2 km are recommended. 
 

3.2 

RS-422 interface connection 

RS-422  interface  connector  is  DB9F  (female),  signals  assignment  to  the  contacts 
(see  the  Fig.).  If  the  OUT  +5V  and  IN  +8V  signals  are  not  used  the  DTE  can be 
connected to the converter via the cable up to 1200m long or the tolerable supply 
voltage decrease limits the cable length. 

 

 

Содержание E174

Страница 1: ...RS 422 Multimode Fiber Optic Converter ELO E174 Operation manual ...

Страница 2: ...peration principles 3 3 0 Installation 3 3 1 Optic link connection 3 3 2 RS 422 interface connection 3 3 3 Power supply connection 4 4 0 Specification 5 4 1 Parameters 5 4 2 Optical parameters 5 4 3 Other 5 5 0 Testing 5 6 0 Troubleshooting 6 7 0 Ordering Information 6 ...

Страница 3: ...of the RS 422 interface Maximum data rate limit is 115 2 kbps LED diodes indicate the transmitted and received signal 3 0 Installation This part describes the ELO E174 converter installation principles 3 1 Optic link connection ST 400 connectors are used to connect the fiber optic cable To connect two converters the TRANSMIT connector of the local converter has to be connected to the RECEIVE conne...

Страница 4: ...D labelled 8V indicates this supply The DTE receives the external supply information via OUT 5V signal This arrangement enables to back up the converter supply The external supply 6V is isolated from the RS 422 link Maximum take off is 170mA Caution Do not connect the DC connector if the supply is on Rx Rx Tx Tx GND Ready Vcc out stínění DB9 Signál female RS 422 1 RxA 2 RxB 3 TxA 4 TxB 5 NC 6 NC 7...

Страница 5: ...00 bps 4 3 Other Supply ext DC supply of 6V 200mA galv isolation DC supply of 8V 170 mA from DTE Dimension Length 80mm Width 55mm Height 20mm Weight 80g Stocking temperature 10 to 55 C Working temperature 0 to 50 C Humidity 0 85 non condensing 5 0 Testing When the power supply is connected the appropriate LED has to be alight To work properly at least one of 8V or 6V LED must be alight The LED dio...

Страница 6: ...allation are connected properly Check the power supply Connection in normal Check the power supply operation quit working Check if the cables are connected properly Check if the power supply is on Check if the DTE works properly 7 0 Ordering Information Supply code is ELO E174 Option Supply code for power supply 6V 200mA is ELO E0Q0 ...

Страница 7: ...ELOE174ZKE002 7 Note ...

Страница 8: ...ELOE174ZKE002 8 ...

Отзывы: