Temperature Control
The IDS 01 Series monitors contain a temperature sensor that provides the user with real-time temperature
readings. This reading can be found on the OSD menu by clicking on: Other Menu ► Information ► System
Temperat
ure. If the monitor senses temperatures higher than the operating range, the monitor will go into “Thermal
Protection Mode.” This mode allows the monitor to remain operational during brief periods of use outside of its
operating range.
Example of OSD showing the Video Board Temperature
In Thermal Protection Mode, the monitor will reduce the backlight brightness to bring the internal temperature back
within operating range. While in this mode, brightness cannot be increased. If the internal temperature decreases
below the Thermal Protection Mode temperature for at least five minutes, normal operation is resumed. The OSD
temperature at which the monitor will enter the Thermal Protection Mode is in the table below.
When the Thermal Protection Mode is enabled, the following icon will appear in the Main Menu and the Brightness
Menu. This will indicate that the Thermal Protection Mode is active.