Elnur INTERTIARX10E Скачать руководство пользователя страница 7

 

WEEKLY PROGRAMMES 
 

It is possible to allocate different programs to different days of the week. To do this, the controller has to be upgrade from 24hr mode (factory 
default) to 24hr/7days mode as follows: 
 
Move the selector to 

0

 position, the display will be Off. Press the 

 key and at the same time turn the selector to 

P

 position maintaining the 

 

key at least five seconds. The display will show 

P-SE

 which means that weekly mode has been set.

 

 
SETTING  THE  DAY:  Press  the 

 key  more  than  two  seconds  and  the  display  will  show  the  number  of  the  day.  Set  the  correct  number,  if 

required, by pressing 

+

 or 

 keys. Press the 

 key and the display will show now the time.  Press again the 

 key and new values will be 

stored. 
 
 

To check a programme or to make a new one press

  PRG 

key: The display will show 

dia1

 .  Press again 

PRG 

key and the display will 

show 

00:00 

 intermittently. Follow now the steps from DAILY PROGRAMMES section until the display shows again  

dia1

 .  Repeat this 

process with the 7 days of the week. When the display shows 

dia7

  the weekly program will be stored by pressing 

+

 key.  

 

 If the display shows 

dia1

 

then, pr key more than three seconds will copy the day 1 program to day 2 and so on. 

 

It is possible to allocate any of the three temperature levels to all the intervals of any day maintaining the relevant  

    

   

T

 

key 

until an audible signal is heard. 
 

 
To turn back a controller from 24hr/7days to a single 24hr press 

PRG 

key more than six seconds. This will restore the factory default settings. 

 
KEYBOARD LOCK 

Press the 

T

 key more than six seconds and the keyboard will be locked. The display will show 

 

 and the controller will keep on 

working internally.  To unlock the keyboard press again the 

T

 key more than six seconds. 

 

4. - CLEANING AND MAINTENANCE  

 

Clean and dust with a dry, soft cloth only when the unit is disconnected and cold.  
 
Do not use solvents or abrasive products for cleaning. 
 
This thermal radiator has been manufactured under an assured quality system using environment friendly processes.                 
 
Please take the heaters to a clean point once their useful life is finished, in order to recycle their materials in the right way. 
 

5. - TROUBLESHOOTING 

 

- The thermal radiator does not heat. 

Check the heater or the air inlets are not covered.  

Digital models:  the display shows the time press the 

T

 key to switch on the heater. Check that the DAY 

or NIGHT temperatures are right. 

 

- The room does not reach the right 
 temperature.  

Check  the  selected  temperature  is  in  accordance  with  the  desired  temperature.  Maybe  the  room  needs 
more heating power. 

 

- DAY and NIGHT luminous indicators 
are lit at the same time. 

Digital  models:  Continuous  mode  has  been  selected.  Turn  the  knob  to  the  “P”  position  to  return  to  the 
Program mode if required. 

 

- The display shows “Err1” or “Err2”  

Digital models: Contact the after sale service. 

 

- Only daily programmes.

 

The controller is in a single 24hr mode (factory default). See WEEKLY PROGRAMMES section to swift to 
24hr/7days mode. 

- The keyboard is locked.

 

If the display shows 

 

the keyboard is locked. To unlock the keyboard press the 

T

 key more 

than six seconds. 

Содержание INTERTIARX10E

Страница 1: ...INTERTIA ELECTRIC RADIATOR RX4P RX6P RX8P RX10P RX12P RX14P RX4F RX6F RX8F RX10F RX12F RX14F RX4E RX6E RX8E RX10E RX12E RX14E Please read these instructions before installing or using this appliance...

Страница 2: ...ble connection box positioned adjacent to the heater The supply circuit to the heater must incorporate a double pole isolating switch having a contact separation of at least 3 mm If the flexible power...

Страница 3: ...aintains the set temperature with the temperature selector dial Moon mode on the heater maintains a temperature 3 C lower than the one set with the temperature selector dial The studs and screws are i...

Страница 4: ...ify the set back value from 3 C to a different one Press the key four seconds and the display will show 3 0 as the factory default value Increase or decrease the value using the and keys The new set b...

Страница 5: ...s frost protection mode Position I The heater is maintaining the SUN temperature constantly both luminous indicators SUN and MOON will be lit This could be useful when SUN temperature is required and...

Страница 6: ...d both luminous indicators will be off Press the key to go to the next interval The display will show 00 30 intermittently and again press one of the three keys T to allocate SUN MOON or OFF frost pro...

Страница 7: ...six seconds This will restore the factory default settings KEYBOARD LOCK Press the T key more than six seconds and the keyboard will be locked The display will show and the controller will keep on wo...

Страница 8: ...8 WIRING MODELS RX P R heating element Ts safety cut out C three way selector MODELS RX F R heating element Ts safety cut out MODELS RX E R heating element Ts safety cut out C three way selector...

Страница 9: ...d electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by i...

Страница 10: ...ION INSTRUCTIONS AND USER GUIDE WEB VERSION ELNUR UK Ltd Unit 1 Brown Street North Leigh Lancashire WN7 1BU www elnur co uk Customer Service Department Telephone 44 0 1942 670119 technical elnur co uk...