![Elnur Gabarron G CONTROL HUB Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/elnur-gabarron/g-control-hub/g-control-hub_nstallation-instructions-and-user-manual_2395217011.webp)
10
EN
Heaters association
With the hub in discovery mode
-
Radiators and Storage Heaters:
Press OK button of the heating device for 3 seconds to
link the heater with the G Control Hub.
-
Thermostat:
Keep press Power and Link buttons of the thermostat at the same time for 3
seconds to link the thermostat with the G Control Hub.
G Control PM association (Power meter)
The installation can be completed with a power meter installed in the electrical distribution box of
your home, which will be used both to know the current energy power and historical energy
consumption and to limit the consumed power coordinating the consumption of the different heaters
connected not to exceed the maximum power established by the user. (Energy manager).
To link the G Control PM with the G Control Hub, once the discovery mode in the hub is activated,
press with the help of a paperclip or a sharp object the interior button of the device. The LED light
placed on the power meter indicates the status of the linking.
LED Status
Description
LED off
Not associated
LED blinking every 2 seconds
Correctly associated
LED blinking every half a second
Associated with the hub, bur
currently lost the connection.
A maximum limit of total power installation can be set by the user using the web-app. The system
disconnects the heaters following the priority order previously set when the energy power is going to
exceed the maximum power established by the user. If several heaters have the same priority, the
system will first disconnect the one that is closer to its set point temperature.