22
3.3. Default settings and Unit reset
To reset the unit to factory default settings, press
and
simultaneously for 5 seconds until the message SrES is displayed.
Confirm the reset with
.
Default Values
Sun
: Comfort temperature
21ºC
Moon
: Economic temperature
18ºC
Frost protection temperature
3ºC
UP01
: Initial % of storage charge
100%
UP02
: Starting time off peak period 1
00:00
UP03
: Ending time off peak period 1
08:00
UP04
: Starting time off peak period 2
00:00
UP05
: Ending time off peak period 2
00:00
UP06
: Charging days of the week
Default -> Charging 7 days of the week.
UP07:
Ambient sensor Offset
0ºC
UP08
: Max. Balancing element
–
working period
5 hours
UP09
: Overtemperature protection
2ºC
UP10
: Temperature Unit
ºC
UP11
: Open Window Detection Function
Off
UP12:
Adaptive Start Control
Off
UP13:
Kind of temperature control
PID
Default Programming
Comfort
: 07:00 to 22:00.
Eco
: 00:00 to 07:00 & 22:00 to 00:00.
UP14
: Weekend Balancing Element restriction
On
Incorrect time settings, erroneous programming of the reduced rate time and too high temperature settings may result in a high cost
of your electricity bill.
i