3.2. Quick Start
Ecombi Plus quick start only requires 2 easy settings:
TIME AND CHARGE SETTING
Charging Hours: By default, Ecombi Plus off-peak period is set from 00:00 to 08:00. In case off-peak period of your electricity
tariff does not match with this setting, you can easily modify it:
-
With backlight on, keep pressed
button for 5 seconds until the message
“Func.”
is displayed blinking to access the
general configuration menu.
-
Press
button until the text
“
PArA
”
is displayed blinking.
-
Press now
button to access general parameteres menu (
PArA
).
-
Parameter UP01 is displayed. Charging period used by Ecombi Plus goes from UP02 parameter (Charging period start.
By default 00:00) to UP03 parameter (Charging period end. By default 08:00).
-
Use
and
buttons to move forward and backward until the parameter to be modified is displayed. Press
button to access the parameter value.
-
Use
and
buttons to modify the start time / end time of the charging period. Use
button to confirm the
desired value.
-
Press
to exit main menu.
Time setting: Ecombi Plus time setting is set on factory by default. Check the time setting in your device. In case time setting is
wrong, you can easily modify it following next steps.
OPERATION MODE SETTING & TEMPERATURE SET POINT
1. With backlight on, keep pressed
button for 5 seconds until the message
“Func.”
is displayed blinking to access the
general configuration menu.
2. Press
button when the message
“
Func.
”
is displayed to access operation mode menu.
3. Press
or
buttons to select basic (24 hours Set-Point Temperature) operation mode. Press
button to confirm.
Current charge level and set-point temperature are displayed in this mode.
4. Once selected, adjust the desired set-point temperature using
and
. Automatically, Ecombi Plus will manage and adjust
daily its charging level to provide the selected temperature with minimal cost.