background image

Elna International Corps. SA 

Xquist 

service manual 

 
 
 

1.

 

Height of the threading hook is improper. 

Check the adjustment of the needle threader 
(see page 29) 

2.

 

Thread tensed in front of needle is not in the center 
of needle eyelet at the lower position of the transfer 
body. 

Check the vertical adjustment of the lower 
position (see page 30). 

3.

 

Longitudinal position of the transfer body in terms 
of needle is not proper at the lower position of the 
transfer body 

Check the longitudinal adjustment of the 
lower position (see page 30). 

4.

 

Thread retaining section is open at 
the lower position of the transfer 
body. 

Check the adjustment of the retaining 
pressure change-over link (see page 30). 

Thread fails to pass 
the needle eyelet. 

5.

 

The base tension is open when threading 

Check the adjustment of the base tension 
(see page 8). 

1.

 

The base tension is open when threading 

Check the adjustment of the base tension 
(see page 8). 

2.

 

The position of needle clamp threading arm is too 
high. 

Check the height of needle clamp threading 
arm (see page 30) 

3.

 

The transfer body is attached to the left side. 

Check the lateral adjustment of the transfer 
body (see page 30). 

Thread is not caught 
by the needle clamp 
thread guide. 
Needle thread fails to 
enter the fork end. 

 

4.

 

Longitudinal position of the transfer 
body is improper. Front and rear. 

Check the longitudinal adjustment of the 
lower position (see page 30). 

1.

 

The transfer body is attached to the left side. 

Check the lateral adjustment of the transfer 
body (see page 30). 

2.

 

The position of needle clamp threading arm is too 
high. 

Check the adjustment of the height of needle 
clamp threading (see page 30). 

The needle clamp 
thread guide fails to 
catch thread.  
Thread deflects to the 
inside of the thread 
guide and cannot be 
caught. 

 

3.

 

The thread path control plate is attached to the left 
side. 

Adjust the thread path control plate (see 
page 30). 

1.

 

The transfer body is attached to the right side. 

Check the lateral adjustment of the transfer 
body (see page 30). 

2.

 

The position of needle clamp threading arm is too 
low. 

Check the adjustment of the height of needle 
clamp threading arm (see page 30). 

The needle clamp 
thread guide fails to 
catch thread.  
Thread deflects to the 
outside of the thread 
guide and cannot be 
caught. 

 

3.

 

The thread path control plate is attached to the right 
side. 

Adjust the thread path control plate (see 
page 30). 

1.

 

Malfunction of the threading body 

Installing position of the face plate is 
improper 
The face plate inside cover is moved to the 
right. 
(The face plate installing plate is slanting 
attached.) 
Defective change-over of STM 

2.

 

Malfunction of the base tension 

Check the motion of the base tension 

3.

 

Malfunction of the mis-threading preventing plate 

Check the motion of the mis-threading 
preventing plate. 

Defective threading 
to the thread take-up 
spring and thread 
take-up lever. 

4.

 

Rising amount of the auxiliary roller cover 

 

Содержание xquisit

Страница 1: ...SERVICE MANUAL 08 02 Printed in Switzerland 395 902 82...

Страница 2: ...s disengaged at the first turn The machine actuates the thread trimming knife to cut the thread 115 rpm and stops with its needle up Disengagement of the main shaft is released before stop 3 Automatic...

Страница 3: ...n 12 Prevention of wrong setting of needle It is designed so as not to insert the needle in the wrong direction 13 Operation guide How to operate the sewing machine advice and how to sew are indicated...

Страница 4: ...inding 600 15 rpm Max sewing speed in medium high speed operation For zigzag pattern 700 50 rpm When bartacking buttonholes on both sides 525 15 rpm Max sewing speed in medium speed operation For embr...

Страница 5: ...c thread trimmer P 21 Base tension P Disengaging the knife P 24 Lateral position of the thread trimmer cam P 24 Moving knife guide upper P 25 Moving knife guide lower P 25 Height of the looper P 26 Bo...

Страница 6: ...adjustment of the lower position see page 30 1 The transfer body is attached to the left side Check the lateral adjustment of the transfer body see page 30 2 The position of needle clamp threading ar...

Страница 7: ...3 Thread has not completed and the bobbin thread is removed by the needle thread Same as 1 and 2 above The hook cover pile is excessively tilted Thread is not cough by the inner hook thread guide 4 T...

Страница 8: ...rews 1 and 2 2 Remove the under cover FACE PLATE COVER 1 Loose the screws 1 and 2 2 Remove the claw section A and B using a thin screwdriver or the like BELT COVER 1 Remove the two screws 1 2 Insert a...

Страница 9: ...base FRONT PANEL 1 Remove screws 1 and remove the needle plate 2 Remove the screw 2 and loose the screw 3 3 Insert a thin screwdriver into section C and remove the claw 4 Applying force to section A i...

Страница 10: ...ector 8 connected to the inverter circuit board To remove the Rear panel 1 Remove the Under cover 2 Remove the Belt cover 3 Remove the Free arm bottom cover 4 Loose the 5 screws from the bottom plate...

Страница 11: ...L 1 Remove the screws 3 and 4 2 Lower presser lifting lever 5 3 Lift handle 6 draw section 7 and remove the rear panel 4 Remove claw section 8 from the bottom plate EMBROIDERY UNIT FRAME OF EMBROIDERY...

Страница 12: ...t screw 1 and the tree screws 2 from the needle throwing STM installing plate 3 Move needle throwing STM installing plate 3 to the left or right to adjust the distance of 2 mm between the main shaft d...

Страница 13: ...5 Remove the Rear Cover see below MAIN MOTOR 1 Remove the screw 1 situation of this screw Turn the hand wheel so that the needle bar is in lowest position this screw fixe the rear cover and is to reac...

Страница 14: ...R 1 Remove the two screws 1 2 Disconnect the motor 3 Remove the motor belt MAIN MOTOR How to adjust the motor belt Adjust the motor belt tension by moving the motor up or down and after the adjustment...

Страница 15: ...of thread retaining plate A temporarily determine the height and fix it 2 Turn the bobbin thread intermediate gear by hand to move thread retaining plate A in the state that the throat plate and the h...

Страница 16: ...SA Xquist service manual Adjust the height so that the clearance provided between the upper plane rib which is higher of the bobbin rib and the bottom end of thread retaining plate A is 0 to 0 3 mm at...

Отзывы: