1 What you get:

1.  Smoke Detector
2.  E520.30 Interface with cable for connecting smoke detector
3.  CD with software and driver

1.  PC with Windows operating system and USB interface

1.  Connect cable from smoke detector to E520.30 Interface 
2.  Connect USB cable to PC
3.  If necessary, install FTDI driver from driver folder on CD, installation guide in doc folder
4.  Start smoke.exe in demo folder on CD

The E520.30 PC driven demonstrator kit is for demonstration purpose of the smoke-detector device functionality. It supports 
communication between PC and smoke detector based on E520.30 using the E520.30 Interface (3 level interface). The E520.30 
device inside the smoke detector has a special firmware to communicate with the PC using the same protocol.
The PC demo software provide smoke detector device control and parameter modification with graphical output.
For demonstration purpose it is necessary to establish a communication between smoke detector and PC using physical se-
quential interface on two wire bus (LN24 and GND). 

2 What you need in addition:

3 Start of operation: 

Figure 1.  Demoboard

4 E520.30 PC driven demonstrator kit: 

Содержание E520.30

Страница 1: ...E520 30 PC driven demonstrator kit is for demonstration purpose of the smoke detector device functionality It supports communication between PC and smoke detector based on E520 30 using the E520 30 In...

Страница 2: ...s automatically to the smoke detector via E520 30 interface After connecting the software shows the measured supply voltage and the LN24 supply The LN24 supply can be set in LN24 Properties window To...

Страница 3: ...interface and can also be displayed LN24 properties can be inspected with LN24 Properties option in the Menu Bar Functions The following values must be set for correct communication with the firmware...

Страница 4: ...E520 30 register values can be read by pressing the readAllRegs button To change a value click in the nVal field and fill in a new value in the upcoming window Confirm with OK Optionally change more r...

Страница 5: ...apter only fit in one position connect again in the Function pull down menu in main window choose Flash in the Memories pull down menu in main window a new Flash window appear see Figure 8 press Load...

Страница 6: ...mable Smoke Detector Controller AN 0129 Mar 25 2015 Figure 9 Flash window with Hex File Figure 10 Flash window during programming Figure 11 Successful flash verify This kind of programming is only rec...

Страница 7: ...K TDI TDO D2 RED LED LN0 TCK LED 1 LN0 2 D5 3 RED 4 DIN 5 DSUP 6 VTDRV 7 VTSEN 8 TEN 9 IO3 TCK 10 IO2 TMS 11 IO1 TDI 12 IO0 TDO 13 LN24 14 IC1 520 30 TEN CT1 100uF 6 3V 1 1 3 3 7 7 5 5 8 8 6 6 2 2 4 4...

Страница 8: ...ion in part or whole without the prior written consent of Elmos is prohibited Elmos Semiconductor AG provide the E520 30 Demonstration Board simply and solely for IC evaluation purposes in laboratory...