With testi ng by the control, the ELMON relay 31-33 system sati sfi es the Cat. 2 require-
ments in accordance with EN ISO 13849-1:2015
"Safety-related parts of control
systems"
.
Without testi ng, the operati on or wiring of the ELMON relay 31-33 sati sfi es no specifi c
safety requirement.
ELMON relay 31-33
Safety Relay
English
U
Test
12 V . . . 28 V AC/DC
6.3 Test
For a standard-compliant design of the protecti on, the primary machine control must perform a test prior
to each dangerous movement or during the non-dangerous phase/movement of the machine. Upon appli-
cati on of the test signal, the output terminal of the switching unit must open. This change in switching state
must be evaluated by the primary machine control . If the test result is correct, the machine control then
initi ates the movement or the next work step. Otherwise, the control must output an error message and
the power-driven work equipment (e.g. motor) must receive a switch-off signal from the machine control.
The available test signal can be selected with the DIP slide switch.