![Elmo TD4114 IP II Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/elmo/td4114-ip-ii/td4114-ip-ii_instruction-manual_2394782016.webp)
- 15 -
3. Alarm
Alarms are caused by “alarm 1”, “alarm 2”, and “motion detection”.
You can set an alarm action for each cause. “With/Without alarm”, “Send e-mail/Send
FTP/Both/None” are available.
Note:
An alarm remains output from the alarm output terminal for ten
seconds. The alarm output period is fixed.
Specifications of the alarm output terminal: Open collector output,
maximum rating: DC12 V, 30 mA
Note:
The next alarm input can work normally three seconds after the
current alarm is input. If the alarm input is active again within three
seconds, the alarm input may not work normally depending on the
equipment status.
Connected
to
network
None
6P connector
(black)
Send e-mail
(See page 35, 57
for setting)
Send FTP
(See page 37, 58
for setting)
Both
(See page 35, 37,
57 and 58 for setting)
Alarm input 1
(non-voltage make contact input)
Pin
Code
Signal
name
No.
color
1
Blue
Alarm input 1
2 Violet
GND
Alarm input 2
(non-voltage make contact input)
Pin
Code
Signal
name
No.
color
3
Gray
Alarm input 2
4 White
GND
Alarm output
(open collector output)
Pin
Code
Signal
name
No.
color
5
Black Alarm
output
Input
Output