21
Note:
"
" in the data column means that SPACE [20H] should be transmitted twice.
Table of the communication commands
When the electronic image enlargement is ON, the enlarged
image moves.
1: To the right side
2: To the left side
3: To the upper side
4: To the lower side
5: To the upper right
6: To the upper left
7: To the lower right
8: To the lower left
Function
Command Parameter
Data
Comments
Auto Focus
0
+ (NEAR)
– (FAR)
0 (STOP)
+ (TELE)
– (WIDE)
0 (STOP)
0 (OFF)
1 (L:ON)
2 (L, R:ON)
0 (POSI)
1 (NEGA)
0 (COLOR)
1 (B&W)
+ (OPEN)
– (CLOSE)
0 (STOP)
1 (NORMAL)
AF
FO
ZO
IR
PL
NP
CB
PM
Command to execute the one-step auto focus.
Focus
adjustment
Command to adjust the focus.
Zoom
adjustment
Command to adjust the Zoom.
Iris adjustment
Command to adjust the Iris.
Lighting
selection
Command to select the Lighting.
Nega/Posi
conversion
Command to convert Nega/Posi.
Color/B&W
selection
Command to select Color/B&W.
Enlarged
image
movement
0 (OFF)
1 (ON)
MA
0 (OFF)
1 (ON)
LL
0
DF
Electronic image
enlargement
Command to enlarge the image to double the center area of
the image.
Local lockout
Command to invalidate the switches on the front operation
panel and wireless remote control.
Default
Command to reset to the initialized mode.
0
0
QS
QR
0 (OFF)
1 (ON)
SA
0 (OFF)
1 (ON)
SC
Status request
Command to inquire the status of the equipment.
ROM version
Command to refer to the ROM version.
Acknowledge
check
Command to select the command acknowledge for each
operation command. (Default :ON)
Add CR
command
Command to add CR [0Dh] to the end of the acknowledge
data. (Default :OFF)