Elmes Electronic STB12VM1 Скачать руководство пользователя страница 2

 Elmes Electronic 04.2015. All rights reserved. 

 

www.elmes.pl

  mail

[email protected]

 

 

PROGRAMMING PROCEDURES

 

1. Learning transmitter(s) to controller's memory 

– maximum 112: 

a)   press control unit 

PRG 

switch for less than 2 seconds (PRG LED lights on), 

b)  press transmitter button - LED in controller switches off, 
c) 

press again the same transmitter’s button – blinking controller LED confirms end of procedure.  

2. Programming motor rotation time and PAUSE time:  

this procedure can be performed with transmitter learned to controller’s memory or using 

wall switch connected to WR input. 

a)  press control unit PRG switch for more than 2 and less than 8 seconds (PRG LED lights on). Releasing the switch PRG LED sets off, 
b)  press any hand transmitter button or wired wall switch ( LED lights on) to start motor rotation, 
c)  after required motor rotation time has lapsed (max. 60 minutes) press the transmitter button or WR switch again - motor stops, courtesy lamp 

will switch on,  

d)  after  required  PAUSE  time  has  lapsed  press  transmitter  button  or  WR  switch  again  - 

the lamp switches off and the controller’s  LED starts 

blinking confirming end of the procedure. 

3. Deleting all transmitters from control unit memory 

(procedure performed when transmitter is stolen or lost)

press controller's 

PRG 

switch (PRG LED lights on) and hold pressed for more than 8 seconds, until the LED starts blinking confirming end of the 

procedure. Transmitter memory in the controller is cleared while programmed timings remain unchanged. 

Installation:

  The  control  panel  should  be  installed  inside  protective  case  to  avoid  direct  exposure  to  harsh  environmental  conditions  and  electric 

interference.  Connection  of  wires  should  be  conducted  from  downwards  of  the  case  to  avoid  possible  water  flow  to  the  controller  board.  External 
antenna  may  be  connected  to  the  controller  by  coaxial  cable  as  shown  on  connection  diagram  below.  Simple  wire  antenna,  as  delivered  with  the 
controller, can also be used, however practical operating range of hand transmitters may be reduced. 

 

 

If photo cells are not used, connection terminals 2 and 3 (counted from the left) must be shorted.

 

 

 

Specification 

  control panel supply 12VAC with max. 100 mA idle current draw, motor 6,3A fused,  

  courtesy/warning lamp 40W max., photo cell supply output 12VDC 240mA max., motor oper

ating time 1s…60min., 

  regulated overload sensitivity 

level 3,5…10A, PAUSE time or lamp ON after motor stops programmable 1…255 seconds, 

  external dimensions (l/w/h) 140/75/30 mm, operating temperature range: from -20

C to +55

Celsius. 

 
Manufacturer

:  ELMES ELECTRONIC, 54-611 Wroclaw 

– PL, ul. Avicenny 2, tel. (+48)71-784-59-61, fax (+48)71-784-59-63 

 

Elmes Electronic declares that the product has been manufactured and tested to comply with the following standards: 
EN  60950-1  :2001  electric  safety,  EN  301 489-1  V1.4.1  (2002-08)  EMC  for  radio equipment,  EN  301 489-3  V1.2.1 (2002-08) EMC for 
Short Range Devices, EN 300 220-3 V1.1.1 (2000-09) EMC and Radio Spectrum Matters. 

 

Manufacturer’s Limited Warranty

 

Elmes Electronic remote control sets carry one-

year manufacturer’s warranty as from date of purchase. The warranty is limited to the replacement of 

faulty original parts or repair defects of improper manufacture. Damage, faulty use or improper handling by the user or installer as well as any chang-
es in product’s hardware or software caused by the user violets the warranty and all due repair costs will be charged. Elmes Electronic shall not be 
responsible for any direct or indirect personal or material damage caused by its products failure to operate correctly.   
 
 
Elmes Electronic reserves the right to change product specification without prior notice.  

KEELOQ

®

 is a registered trademark of Microchip Technology Inc., USA. 

 

Installation of the controller should be made  with power supply OFF and according to schematic diagram below.

 