background image

 

 

www.elmes.pl 

 [email protected]                                                                                                      

Elmes Electronic 11.2010 All rights reserved. 

 
 
 

PROGRAMMING PROCEDURES 

Programming is made with CH4H receiver front panel taken off and the use of programming PRG switch on the receiver’s board. 

1.  LEARNING HAND-HELD AND OTHER TRANSMITTERS TO RECEIVER’S MEMORY (maximum 40): 

  Before  entering  this  programming  mode  it  is  recommended to determine which hand transmitter’s button or RP501 transmitter’s input should control which output 

channel of the receiver. 
Step 1.     Press receiver's PRG switch for less than 2 seconds. Receiver’s central LED switches to red and channel no 1 LED will illuminate, 
Step 2.     Shortly pressing the PRG switch (for less than 2 seconds) selects the required output channel for the transmitter, 
Step 3.     Press the PRG switch for more than 2 seconds, so as the main receiver’s LED changes to green, 
Step 4.     Depending on type of transmitter to be learned proceed as follows: 

hand-held transmitter – double press transmitter’s button. With multi channel transmitters double press button 

 

number respective to number of output channels required to be controlled, as in examples below: 

 

Example 1: double pressing button 4 of hand transmitter CH4H with receiver’s channel output 4 selected at step 2 

 

above will learn all four buttons to the receiver. Now, button 4 controls output 4, button 3 controls output 3, 

 

button 2 controls output 2 and button 1 controls output 1. 

 

Example 2: double pressing button 3 of hand transmitter CH4H with receiver’s channel output 4 selected at step 2 

 

above will learn first three buttons to the receiver. Now, button 3 controls output 4, button 2 controls output 3, button 1 

 

controls output 2. Button 4 of this transmitter will not be active for this receiver. 

 

Example 3: double pressing button 4 of hand transmitter CH4H with receiver’s channel output 2 selected at step 2 

 

above will learn two last buttons to the receiver. Now, button 4 controls output 2 and button 3 controls output 1. 

 

Buttons 1 and 2 of this transmitter will not be active for this receiver. 

wireless  detectors  PTX50,  CTX3H,  CTX4H,  GBX  –  activate  transmissions  as  described  in  detectors’  manuals. Except for detector GBX, all other detectors’ 
boxes must be closed!  

RP501 transmitter – set the transmitter’s required mode of operation and activate transmission by disconnecting any of its inputs from the ground. 

Receiver’s LED blinking green slowly indicates end of procedure. LED’s blinking fast red indicates programming error and the procedure must be repeated. 

2.  SETTING RECEIVER’S RELAY OUTPUTS TIMING IN PULSE OPERATION (monostable mode):   

Step 1.    Press receiver's PRG switch for more than 2 and less than 8 seconds, LED switches to red and again to green indicating entering this programming mode 

(channel no 1 LED is on and ready for programming set time), 

Step 2.    Shortly pressing the PRG switch (for less than 2 seconds) select the required channel,  
Step 3.    Press PRG switch for more than 2 seconds until the receiver’s LED switches to red, 
Step 4.    Press PRG switch and the receiver’s LED switches to green indicating start of the channel output set on time counting. When required set on time has lapsed 

 (maximum 4 hours) press the PRG switch again to stop the procedure – LED switches to red. 

After a short while receiver’s LED blinking green confirms end of the procedure. 

3.  SETTING RECEIVER’S RELAY OUTPUTS TO ON/OFF (LATCHED) OPERATION (bistable mode):   

Steps 1,2,3.  Follow programming steps exactly the same way as in setting monostable operation mode in procedure number two above. 
Step 4.     Triple press shortly PRG switch with less than two seconds intervals. After a short while receiver’s LED blinking green confirms end of the procedure. 

4.  DELETING ALL HAND-HELD AND OTHER TRANSMITTERS FROM RECEIVER’S MEMORY: 

Keep pressed receiver's PRG switch for more than 8s. Initially, the receiver’s LED switches to red and after two seconds to green. After next six seconds the LED 
starts  blinking.  Release  the  switch.  The  transmitters’  memory  of  the  receiver  is  now  cleared,  however  channels’  programmed  modes  of  operation  remain 
unchanged. The receiver will not respond any more to signals sent from any transmitters. 
To learn new transmitter(s) to the receiver's memory follow procedure 1. To change output channels operating mode follow procedure 2 or 3 above. 
 

5.  DELETING SINGLE TRANSMITTER FROM RECEIVER’S MEMORY: 

Except for RP501 transmitters, it is possible to delete any other single transmitter from receiver’s memory under condition that the transmitter to be deleted is in 
our possession. This tricky procedure requires performing steps 1,2,3 of transmitter’s learning procedure 1 above, whereas two succeeding transmissions at step 4 
(double  pressing  transmitter’s  button)  to  be  performed  in  the  following  way:    first  transmission  must  be  sent  from  the  transmitter  to  be  deleted  and  second 
transmission  from  any  other  transmitter  (e.g.  by  pressing  other  button  in  multi  channel  hand  held  transmitters).  Receiver’s  LED  blinking  red  will  indicate 
programming error – in this case meaning that the transmitter is deleted. The receiver will not response any more to signals sent from deleted transmitter. 
 

 
NOTE!  Programming errors and no programming activity longer than 30 seconds are indicated by fast blinking LED in red, after which the 

programming mode sets off automatically. 

 

CH4H transmitter 