Figure 2.  Sample diagram of alarm installation with a buffered power pack.  
 

+

OUT2

OUT3

_

Z1 buffer

Siren

Strobe

External siren

12VDC/1A

+

-

Phone dialer

GN

D

+12V

Tamper

R 10kOhm

Tam

per

Alarm

Arm

ed

GND

OUT1

TAMP

VDC

Fig. 2

Z2

Power Failure

AKU

CB32

power pack

GSM

GSM Phone
AC Power

Pack

 

 
 

SPECIFICATION 

 

superheterodyne receiver 433.92 MHz, sensitivity better than  -102dBm, 

 

supports up to 32 Elmes wireless detectors defined as alarm zones, 

 

supports up to 16 named users (inclusive of 4 administrators), 

 

interface to a GSM phone (SMS/CLIP notification) accepting AT commands, 

 

non-volatile EEPROM memory of last 256 events, 

 

polymer fuse protected outputs OUT1-3 with up to 1A current draw, 

 

internal siren/buzzer with alarm sound level - 92dB (at 40cm distance),  

 

included AC power pack with 9-12VDC/150mA output, 

 

backup power with two AA rechargeable batteries of up to 2000mAh each, 

 

up to 72 hours autonomy operation with two 1800mAh rechargeable batteries, 

 

external dimensions (without antenna): 110/122/32mm (width/height/thick),  

 

indoor use only, with temperatures range from 0 to +40 ºC. 

 
Manufacturer: 

Elmes Electronic, 54-611 Wroc

ł

aw-PL, Ibn Siny Avicenny 2, 

Phone: +48717845961, Fax +48717845963, e-mail: [email protected] 
 

Certified BY Z.R.T.O.M. “TECHOM” (PL)  No. 106/05 - class “B” 

- 20 - 

The product complies with the requirements of the following security standards: 

1.

 

PN-93/E-08390-14:1993 Alarm systems - General requirements –Application 

2.

 

PN-EN-50130-5:2002 Alarm systems – Environmental tests 

 

Elmes Electronic declares that the product has been designed and 
manufactured to comply with the EN 60950-1 electric safety standard, 
the EN 301 489-1 electromagnetic compatibility standard and the EN 
300 220-3 radio standard. 

 

LIMITED WARRANTY

 

The manufacturer of this product warrants the original purchaser that for a period of 24-months as 
from the date of purchase, the product shall be free of defects in materials and workmanship in 
normal use. During the warranty period, the manufacturer shall, at its option, repair or replace any 
defective product upon return of the product to the manufacturer, at no charge for labor and 
materials. The defective product must be delivered to the point of purchase in a clean condition 
and at buyer’s own expense, along with this guarantee with the date of purchase confirmed below, 
and a short description of the failure. The cost of dismantling and installing the device is covered 
by the user. The warranty does not cover batteries and damage arising from improper use or 
handling, unauthorized adjustments, alterations and repairs.

 

 
 

Date and place of purchase

…………………….. .......................................................... 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
The use of WEEE symbol indicates that this product may not be treated as household 
waste. By ensuring this product is disposed of correctly you will protect the 
environment. For more detailed information about the recycling of this product, please 
contact your local authority, your household waste disposal service provider or the shop 
where you purchased the product. 
 

 

Copyright: Elmes Electronic – all rights reserved. 

Содержание CB32

Страница 1: ...f two internal 1800mAh AA type rechargeable batteries The panel supports up to 16 system users and enables monitoring of up to 32 wireless detectors identified as alarm zones Each user and each zone may have any defined name with the length of 16 characters The CB32 control panel also supports wireless detectors in wired alarm systems It may be powered from the power supply line of the wired syste...

Страница 2: ...e 24h anti tamper zones remain armed 2 arm arming the alarm On end of the exit delay signaled acoustically and optically with displayed time countdown on the LCD panel all alarm zones are armed Armed status appears on the display 3 day instant arming of the alarm in the day supervision mode The zones earlier defined as day armed and the active 24h zones are armed as in item 3 1 The day mode messag...

Страница 3: ...th the CB32 control panel a dedicated interface cable with integrated phone charger is required and may be optionally ordered from the seller MAIN MENU To access the main menu of the CB32 panel press and hold down OK button for more than two seconds You can navigate the menu using vertical and horizontal cursor keys If the keypad is not used for more than two minutes the menu exits and display of ...

Страница 4: ...itchen living room office Mark s Room etc Uppercase and lowercase letters digits and the following characters space and are accepted Zone number selection is made with the buttons followed by OK button The buttons select the successive letters of the name while the buttons browse the character table Accept the name with OK button The use of C button cancels selection and exits the menu 3 3 Learnin...

Страница 5: ...d Service Settings System Users Password Please follow detailed instructions in Password Change item 1 in Main Menu 10 5 2 Setting and edition of user name Service Settings System Users Name Please follow detailed instructions in Zone name item 3 2 of Service Settings 5 3 Learning and deleting of user remote control Service Settings System Users Remote Please follow detailed instructions in Learni...

Страница 6: ...sed SIE C45 SIEMENS C45 SIE C60 SIEMENS C60 SE T68 SONY ERICSSON T68 T230 Depending on phone model selected an appropriate cable interface must be used The cable interface are optionally available from the CB32 panel supplier 7 7 Defining SMS message incident notification contents ID Codes Service Settings GSM monitoring SMS contents This menu is used to define the contents of ten types 10 of SMS ...

Страница 7: ...llowed by OK button Day or night arming modes cannot be selected 14 NOTE Using two channel remote control with first button used at learning the transmitter to the control panel the transmitter completely arms disarms the system When second button of two channels transmitter was used at learning its use will toggle between day and night arming modes 8 8 Panic alarm call for help function Service S...

Страница 8: ...s only Discharged batteries will be recognised by the LCD panel cease to display any message The AC power pack should be mains 16 plugged again to restore panel operation and recharge the batteries This forming operation will allow maximum capacity of the batteries Operating in wired alarm environment with system backup battery Elmes CB32 control panel may be powered from 12 14 VDC detector line v...

Страница 9: ... the square piece of the backside plastic over the Tamper switch should be removed With the system installed and tested in basic configuration other devices such as an outdoor siren strobe device phone dialer or a GSM phone can be added Also some other functions of the CB32 panel such as anti sabotage of the OUT1 output item 8 4 disable signaling on the internal siren item 8 5 or the RF link test ...

Страница 10: ...Application 2 PN EN 50130 5 2002 Alarm systems Environmental tests Elmes Electronic declares that the product has been designed and manufactured to comply with the EN 60950 1 electric safety standard the EN 301 489 1 electromagnetic compatibility standard and the EN 300 220 3 radio standard LIMITED WARRANTY The manufacturer of this product warrants the original purchaser that for a period of 24 mo...

Отзывы: