Elmes Electronic CB32 Скачать руководство пользователя страница 1

- 1 - 

  
 
 

ELMES CB32 CONTROL PANEL 

v 1.3 03.2006

 

Installation and operation manual – contents: 

 

 

INTRODUCTION..........................................................................................................2

 

KEYPAD USE AND ARMING METHODS ...............................................................3

 

ARMING

 

&

 

DISARMING

 

OF

 

ALARM

 

SYSTEM. 3

 

1.

 

Arming & disarming alarm using control panel keypad. 

3

 

2.

 

Arming & disarming alarm using remote control transmitter. 

4

 

3. 

 

Arming the system with bypassing selected alarm zones. 

4

 

SELECTED FUNCTIONS DESCRIPTION................................................................5

 

MONITOR

 

OF

 

ALL

 

ALARM

 

DETECTORS 5

 

ANTI-SABOTAGE

 

PROTECTION

 

OF

 

EXTERNAL

 

DEVICES 5

 

ALARMS

 

MONITORING

 

USING

 

GSM

 

PHONE 5

 

MAIN MENU..................................................................................................................5

 

ALARM

 

MEMORY 6

 

FAILURE

 

CHECK 6

 

SERVICE

 

SETTINGS 6

 

1.

 

Password Change. 

6

 

2.

 

Event Memory. 

6

 

3. 

 

Alarm Zone Settings. 

7

 

4.

 

Outputs settings. 

9

 

5.

 

System Users - adding, editing and removing a user. 

9

 

6.

 

Times settings. 

10

 

7.

 

Alarm notification & monitoring by GSM phone. 

11

 

8.

 

Auxiliary functions  settings. 

12

 

RESETTING

 

PASSWORD

 

CODE

 

OF

 

USER

 

1 14

 

DESIGNING WIRELESS ALARM SYSTEM..........................................................14

 

POWER

 

SUPPLY

 

SOLUTIONS 15

 

ALARM

 

SYSTEM

 

WITH

 

ELMES

 

CB32

 

CONTROL

 

PANEL 16

 

WIRING

 

DIAGRAMS 18

 

SPECIFICATION ........................................................................................................19

 

LIMITED WARRANTY .............................................................................................20

 

 

- 2 - 

INTRODUCTION 

Elmes CB32 programmable, wireless alarm control panel is designed for use in anti-
burglary, anti-robbery, intrusion detection and access control installations in houses, 
flats, shops, offices, etc. It operates with Elmes Electronic made wireless motion 
detectors, glass break detectors, magnet contact detectors and key-fob transmitters. Its 
three 1A current draw alarm signaling outputs are intended for connecting external 
signaling devices such as sirens, bells or strobes and alarm notification devices as phone 
dialer. The panel features a real-time clock, non-editable memory log of last 256 events 
and may also be programmed to automatically send SMS alarm messages when 
connected to an external GSM phone. The backlit LCD displays appropriate status 
information while numeric keypad allows convenient handling and programming of the 
control panel. In the event of AC power failure, special software procedures minimizing 
energy consumption allow up to 72-hour autonomy with the use of two internal 
1800mAh AA type rechargeable batteries. The panel supports up to 16 system users and 
enables monitoring of up to 32 wireless detectors identified as alarm zones. Each user 
and each zone may have any defined name with the length of 16 characters. 
The CB32 control panel also supports wireless detectors in wired alarm systems. It may 
be powered from the power supply line of the wired system, and its three signaling 
outputs can be connected to the alarm detection terminals of a wired control panel. 

General features of Elmes CB32 control panel: 

- microprocessor architecture, alphanumeric backlit LCD display and real-time clock, 
-  32 wireless alarm zones (detectors) with user defined name, 
- identification of 16 users including 4 administrators with defining their names, 
- arming and disarming of the panel by entering a password (3 to 6 digits security code) 

on the keypad or with the use of remote control transmitter, 

- wide range of alarm zone types for specialized purposes, 
- functional modes of partial arming of the control panel (day, night modes),  
- panic and robbery alarm function (call for help) activated by remote control, 
- interface to GSM phone for monitoring of alarms with SMS/CLIP notification, 
- memory of the last 256 events, such as arming, disarming, alarms and power failures, 
- acoustic signaling (beeps) of entry in a “chime type” zone, 
- entry delay activated either with remote control or by entering of the delayed zone, 
- programmable “entry” and “exit” delay times in the range from 0 to 99 seconds, 
- monitoring of detectors (zones) presence by the control panel, 
- three transistor type alarm outputs with up to 1A current draw, overload protection 

and user defined signaling purpose (alarm, AC power failure or system arming),  

WARNING

!  This wireless control panel has been designed to be effective as much 

as possible. However, there are circumstances that alarm system may fail to operate 
as expected for variety of reasons. Users and installers are warned that radio 
signals from wireless detectors and sensors may not reach the CB32 panel receiver 
under all circumstances that could include metal objects placed on radio 
transmission path, deliberate jamming or other local radio signal interference.

 

Содержание CB32

Страница 1: ...f two internal 1800mAh AA type rechargeable batteries The panel supports up to 16 system users and enables monitoring of up to 32 wireless detectors identified as alarm zones Each user and each zone may have any defined name with the length of 16 characters The CB32 control panel also supports wireless detectors in wired alarm systems It may be powered from the power supply line of the wired syste...

Страница 2: ...e 24h anti tamper zones remain armed 2 arm arming the alarm On end of the exit delay signaled acoustically and optically with displayed time countdown on the LCD panel all alarm zones are armed Armed status appears on the display 3 day instant arming of the alarm in the day supervision mode The zones earlier defined as day armed and the active 24h zones are armed as in item 3 1 The day mode messag...

Страница 3: ...th the CB32 control panel a dedicated interface cable with integrated phone charger is required and may be optionally ordered from the seller MAIN MENU To access the main menu of the CB32 panel press and hold down OK button for more than two seconds You can navigate the menu using vertical and horizontal cursor keys If the keypad is not used for more than two minutes the menu exits and display of ...

Страница 4: ...itchen living room office Mark s Room etc Uppercase and lowercase letters digits and the following characters space and are accepted Zone number selection is made with the buttons followed by OK button The buttons select the successive letters of the name while the buttons browse the character table Accept the name with OK button The use of C button cancels selection and exits the menu 3 3 Learnin...

Страница 5: ...d Service Settings System Users Password Please follow detailed instructions in Password Change item 1 in Main Menu 10 5 2 Setting and edition of user name Service Settings System Users Name Please follow detailed instructions in Zone name item 3 2 of Service Settings 5 3 Learning and deleting of user remote control Service Settings System Users Remote Please follow detailed instructions in Learni...

Страница 6: ...sed SIE C45 SIEMENS C45 SIE C60 SIEMENS C60 SE T68 SONY ERICSSON T68 T230 Depending on phone model selected an appropriate cable interface must be used The cable interface are optionally available from the CB32 panel supplier 7 7 Defining SMS message incident notification contents ID Codes Service Settings GSM monitoring SMS contents This menu is used to define the contents of ten types 10 of SMS ...

Страница 7: ...llowed by OK button Day or night arming modes cannot be selected 14 NOTE Using two channel remote control with first button used at learning the transmitter to the control panel the transmitter completely arms disarms the system When second button of two channels transmitter was used at learning its use will toggle between day and night arming modes 8 8 Panic alarm call for help function Service S...

Страница 8: ...s only Discharged batteries will be recognised by the LCD panel cease to display any message The AC power pack should be mains 16 plugged again to restore panel operation and recharge the batteries This forming operation will allow maximum capacity of the batteries Operating in wired alarm environment with system backup battery Elmes CB32 control panel may be powered from 12 14 VDC detector line v...

Страница 9: ... the square piece of the backside plastic over the Tamper switch should be removed With the system installed and tested in basic configuration other devices such as an outdoor siren strobe device phone dialer or a GSM phone can be added Also some other functions of the CB32 panel such as anti sabotage of the OUT1 output item 8 4 disable signaling on the internal siren item 8 5 or the RF link test ...

Страница 10: ...Application 2 PN EN 50130 5 2002 Alarm systems Environmental tests Elmes Electronic declares that the product has been designed and manufactured to comply with the EN 60950 1 electric safety standard the EN 301 489 1 electromagnetic compatibility standard and the EN 300 220 3 radio standard LIMITED WARRANTY The manufacturer of this product warrants the original purchaser that for a period of 24 mo...