How to produce slush, sherbets or cold drink 

The maximum amount of liquid that the tank can hold is 1.58 gallons for slush and 1 gallon for creams. 

Clean the machine as described in the CLEANING paragraph. 

 

Turn off the main switch before filling the tank 

 

Remove the cover and pour the mix in the tank.  

 

Don’t fill the tank with only water. In case of freezing product switch off the board until the produ

ct will be 

liquid. 

 

To prepare the product mix use only drinkable water. 

 

the temperature of the poured product must not be lower than 10 °C in order to allow a correct calibration of 
the electronic kit that will be indicated as described in the previous paragraph

 

If the mixture contains alcoholic product, consider that 15%, on total mixture, is the maximum value that can 
come into contact with plastic parts. 

 

Switch on the main switch 

 

Before turning on the main switch, make sure that the cover is positioned on the transparent tank and that it 
is locked by the key. 

 

SLUSH production. 

Selected the slush mode as described on page 9: 

 

vary the viscosity of the product from 1 to 3 using the 

 button. 

Setting the value 1 there will be a granita less viscous and thus more liquid, while setting the value 3, you have the 
maximum possible viscosity (i.e. a very dense slush). 

 

Warning! After each restart of the machine, if the product temperature is higher than 10°C and SLUSH mode 
is selected, the led 3 starts to flash for about 2 minutes

  

 

COLD DRINK production. 

Selected the cold mode as described on page 9: 

 

Big Biz will keep the product at a temperature of about 4 ° C +/- 1 ° C. 

 

In COLD mode should not be formed slush  

 

In order to have slush, sherbets or cold drink, you need a small quantity of sugar per liter. The recommended 
quantity is generally reported in the usage instructions. In case of natural products, we suggest to use a quantity 
that goes from 12 and 22%.

 

 

If the horizontal auger is blocked because of ice blocks due to a lack of sugar or to other reasons, such as foreign 
bodies in the tank, the augers can undergo a break. 

 

 

Содержание BIG BIZ

Страница 1: ...Use and maintenance manual...

Страница 2: ...5...

Страница 3: ...tegral part of the supply and must be carefully read in order to be properly used in compliance with the essential safety requirements has been drafted by following the dispositions Directive 2006 42...

Страница 4: ...en supervision or instruction concerning use of the appliance by a person responsible for their safety Children being supervised not to play with the appliance For correct operation use the machine at...

Страница 5: ...ar of the appliance For safe operation the maximum tilt of the appliance is 1 5 degrees towards the front side outlet Cleaning and user maintenance shall not be made by children without supervision Ch...

Страница 6: ...d to renovate our idea of innovation every day Thanks to this approach today we are considered as leaders in the advanced technology field We therefore work and try to be more and more efficient in th...

Страница 7: ...lity for damages deriving from failure to comply with the following instructions Install the machine according to the mounting instructions The power supply must correspond to the rating plate data pi...

Страница 8: ...e used only for the purposes it was manufactured for Any other use is to be considered as dangerous Installation It is recommended that the installation is carried out by a skilled technician The manu...

Страница 9: ...if you want the machine to last longer it is therefore useful to periodically wash all parts in contact with the product using the following procedure Cleaning the tank Please see the pictures at the...

Страница 10: ...e electronic board at the same time it indicates that the pressure switch intervened to deactivate the compressor In this condition the freezing will be OFF to avoid damage to the refrigeration system...

Страница 11: ...ws to have a slush in the tank The value can vary from 1 to 3 using the button and indicates a less or more slush viscosity product respectively After each restart of the machine if the product temper...

Страница 12: ...itioned on the transparent tank and that it is locked by the key SLUSH production Selected the slush mode as described on page 9 vary the viscosity of the product from 1 to 3 using the button Setting...

Страница 13: ...er wire in order to disconnect the machine from the electrical network Do not remove the panels before disconnecting the machine from the electrical network Do not remove protections and or covers tha...

Страница 14: ...t 5 minutes at least and switch on the machine again select on the electronic board slush mode The electronics calibration is automatic and the status will be displayed on the electronic board by the...

Страница 15: ...13 R290 R290 32 89 6 24 75 2 32 89 6 15 59...

Страница 16: ...14 1 5 8 3 8 70 17 18...

Страница 17: ...15 Elmeco Vision 2000 ISO 14001 Elmeco Big Biz BB ISO 9001 2000 Elmeco www elmeco com...

Страница 18: ...4 Dimensions mm Inches BB1 6 1 58 552x250x475 21 8X9 9X18 7 320 220 240 50 350 115 60 350 220 230 60 BB2 6 6 1 58 1 58 552x440x475 21 8X17 3X18 7 540 220 240 50 550 115 60 540 220 230 60 A B C D E F...

Страница 19: ...17 2 3 Big Biz BB 4 16 Big Biz Elmeco 40 5 32 4 16 6 32...

Страница 20: ...18 18 3 19 10 1 2 60 140 32 33 MOTOR ON 20 8 9 20 21 22 23 20 21 22 23 10 11 12 13 14 15 exp 13 30 16 17 18 19 10 10...

Страница 21: ...19 BB1 220 240 50 220 230 60 1 2 3 1 3...

Страница 22: ...20 LED SLUSH MODE COLD MODE MOTOR ON 1 2 3 SLUSH 1 3 10 SLUSH 3 MOTOR ON LED 1 2 23 www elmeco com...

Страница 23: ...21 1 58 1 10 15 SLUSH slush 20 1 3 1 3 10 SLUSH 3 20 Big Biz 4 1 COLD 12 22...

Страница 24: ...22 5 5 BB2 Timer Defrost 4 1 Timer Defrost 1 1 2 2 3 3 R290 Propane R290 R290...

Страница 25: ...23 Big Biz 1 1 LED 2 15 5 LED 3 1 LED 5 32 19 slush 3 5 LED 3...

Страница 26: ...24 APPENDICE...

Страница 27: ...25 Electric System...

Страница 28: ...26 Electric System...

Страница 29: ...otor EBx Electronic board EVx Solenoid valve 9 Fuse 5X20 F315mA Qx Thermostat TM Timer Defrost 8 Timer switch AS Switching power supply 100 240Vac 24Vdc Colors BRN Brown BLU Blue GRN Yellow Green RED...

Страница 30: ...28 Cooling System GB C Compressor Cn Condenser F Dryer filter B Accumulator Ex Evaporator 1 Discharge line 2 Liquid line 3 Suction line Pr Pressure switch only some models AR C Cn F B Ex 1 2 3 Pr...

Страница 31: ...29 Cooling System AR C Cn F B evx Ex 1 2 3 Pr GB C Compressor Cn Condenser F Dryer filter B Accumulator evx Solenoid valve Ex Evaporator 1 Discharge line 2 Liquid line 3 Suction line Pr Pressure switc...

Страница 32: ...30 Exploded View...

Страница 33: ...SHAFT 19 L0000108 003 TRANSMISSION SHAFT WITH SLEEVE 20 A0000114 001 TRANSMISSION SHAFT GASKET 21 M0004105 002 HORIZONTAL AUGER GEAR 22 M0004102 002 HORIZONTAL AUGER BUSHING 23 L0004103 002 HORIZONTAL...

Страница 34: ...32 40 cm 40 cm 40 cm...

Страница 35: ...33...

Страница 36: ...ing harmonized standards or technical specifications designations which comply with good engineering practice in safety matters in force within the EEC have been applied standards or other normative d...

Страница 37: ...MPROPER INSTALLATION OR OPERATION AS AND NOT LIMITED TO CORROSIVE ENVIRONMENTS NORMAL CORROSION NON PERIODIC CLEANING AND DESCALING IMPROPER STORAGE IMPROPER MAINTENANCE OR REPAIR FIRE FLOOD OR ACTS O...

Страница 38: ...RL 1 877 4 ELMECO 1 877 435 6326 Elmeco Elmeco ELMECO ELMECO COTTER ELMECO SRL ELMECO Elmeco Elmeco srl Elmeco srl Elmeco srl Elmeco LLC Via Circumvallazione Est 12 652 Griffith Road Suite E Casandrin...

Страница 39: ......

Страница 40: ...Elmeco 05 22...

Отзывы: